Inspection Date:03/15/2022 I Inspection Type: Rental Inspection ; Inspection Number:7274 I Shif: N I Cation: N/A
Unit: N/A 1 Lead Inspector:BARRY STRATTON I Other Inspectors: N/A Fee:$50.00g.14,/ - S�
STATUS CODE DESCRIPTION
FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector:BARRY STRATTON-Comments: Padlock and hasp locks need removed from
basement door.Still not corrected.
FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of
egress system shall comply with the requirements of this section.Aisles or aisle
accessways shall be provided from all occupied portions of the exit access that
contain seats,tables,furnishings, displays and similar fixtures or equipment.The
minimum width or required capacity of aisles shall be unobstructed. Exception:
Encroachments complying with Section 1005.7.
Inspector: BARRY STRATTON-Comments:
FAIL 505.1 -Address identification New and existing buildings shall be provided with approved address identification.
The address identification shall be legible and placed in a position that is visible from
the street or road fronting the property.Address identification characters shall
contrast with their background.Address numbers shall be Arabic numbers or
alphabetical letters. Numbers shall not be spelled out. Each character shall be not
less than 4 inches(102 mm)high with a minimum stroke width of 1/2(12.7 mm).
Where required by the fire code official,address identification shall be provided in
additional approved locations to facilitate emergency response.Where access is by
means of a private road and the building cannot be viewed from the public way,a
monument,pole or other sign or means shall be used to identify the structure.
Address identification shall be maintained.
Inspector: BARRY STRATTON-Comments:Need all apartment doors marked with
numbers.
FAIL 605.1 -Aoatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:
Printed on 03/15/2022 1:,10113
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Smoke detectors need to be installed to
meet code standards in building.
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments:
FAIL R2- Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers, heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector:BARRY STRATTON-Comments:Water leak in basement and rear stairs and
furnace.
FAIL R4-Exterior Property Areas Is the exterior property area maintained in a clean,safe, and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds, and pest
infestations.(IPMC 302)
Inspector: BARRY STRATTON-Comments:Garbage
FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and
sanitary state?(IPMC 304)
Inspector: BARRY STRATTON-Comments: Rear stairs to unit#5
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Large accumulation of debris in basement
still needs removed.
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector:BARRY STRATTON-Comments:Furnace ducts rotten in basement. Replace
all bad duct work.
GENERAL NOTES
F'-r c-03/15/2022'g^10.13
Page 2of4
BARRY STRATTON-03/15/2022 @ 10:11 304.10 Stairways,decks,porches and balconies. Every exterior stairway,deck, porch
and balcony,and all appurtenances attached thereto,shall be maintained structurally
sound,in good repair,with proper anchorage and capable of supporting the imposed
loads
BARRY STRATTON-03/15/2022 @ 10:11 305.4 Stairs and walking surfaces.Every stair,ramp,landing,balcony,porch,deck or
other walking surface shall be maintained in sound condition and good repair.
BARRY STRATTON-03/15/2022 @ 10:11 308.1 Accumulation of rubbish or garbage. Exterior property and premises,and the
interior of every structure,shall be free from any accumulation of rubbish or garbage.
BARRY STRATTON-03/15/2022 @ 10:12 309.1 Infestation.Structures shall be kept free from insect and rodent infestation.
Structures in which insects or rodents are found shall be promptly exterminated by
approved processes that will not be injurious to human health.After pest elimination,
proper precautions shall be taken to prevent reinfestation.(Mice)
BARRY STRATTON-03/15/2022 @ 10:12 504.1 General.Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition. Large leak in
basement with water being caught in buckets.
BARRY STRATTON-03/15/2022 @ 10:12 Plumbing system hazards.Where it is found that a plumbing system in a structure
constitutes a hazard to the occupants or the structure by reason of inadequate
service, inadequate venting,cross connection, backsiphonage,improper installation,
deterioration or damage or for similar reasons,the code official shall require the
defects to be corrected to eliminate the hazard.
BARRY STRATTON-03/15/2022 @ 10:12 602.2 Residential occupancies. Dwellings shall be provided with heating facilities
capable of maintaining a room temperature of 68°F(20°C)in all habitable rooms,
bathrooms and toilet rooms based on the winter outdoor design temperature for the
locality indicated in Appendix D of the International Plumbing Code.Cooking
appliances shall not be used, nor shall portable unvented fuel-burning space heaters
be used,as a means to provide required heating.
REINSPECTION BATE
04/13/2022