3��A� ����������DETAILS
Inspection Dare:03/Oie]2J | Inspection Type:Rental Inspection Inspection Number:7Station: N/A �
Unit: N/A Lead Inspector:8ARRYSTR/QTON Other Inspectors: N/A | Fee:$50.00
sxmrUs CODE uExCe/pr/o/V
F�{L 605.1 Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRYSTRATTON Comments:All light fixtures need globes. Light indining
room needs removed and new light installed. Kitchen lights needs a cover and
checked why is does not come on all the time.Outlets in kids bedroom is burnt and
needs changed out.
FAIL 906.1 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group^, B' E^ F, H' |'*1' R'1. R'2'R'4and S occupancies. Exception: in
Group R'2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a pot-table
fire extinguisher having a minimum rating of 1-A:1 O-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas'
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRYSTRATT0N Comments:
FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
mu|tip|e'stationsnookp installed in accordance with Sections 907.2.11.1 through QO7.2.11.6and NpPA72.
alarms
Inspector: 8ARRYSTR^JTON Comments:Smoke detectors are needed ineach
bedroom and outside of the bedrooms.Smoke deteoo''also needed tobein
basement.
FAIL 915.1 General Carbon monoxide detection shall be installed in new buildings in accordance with
SeccionsQ16.1.1 through y15.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRvSTRATTON Comments:[O detectors needed in vicinity ofthe
bedrooms
,��*=oNonz�,�,`�n
' Page 1o,*
STATUS CODE DESCRIPTION
FAIL RI - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either
the public or occupants of the structure?(IPMC 108.1.1)
Inspector: BARRY STRATTON-Comments:
•
FAIL R2- Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator, moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector: BARRY STRATTON-Comments:Electric
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRY STRATTON-Comments:Mold and stairs to upstairs.
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector: BARRY STRATTON-Comments: Floor on front porch.Stairs and decking on
rear porch. Handrails and guards need to installed on stairs for porches.
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Kitchen ceiling needs repaired/water
damage. Both Bedroom ceilings need removed and replaced/water damage.
Bathroom ceiling needs removed and replaced. Mold present because of water
damage. Floors need transition strips. Stairs need repaired. Need new balusters and
stair treads installed.Stairs are unsafe. Broken windows need replaced. Need all
doors to have proper door hardware on them. Holes in living room floor need
corrected. Kitchen cabinets need all drawer fronts and drawers in place. Living room
ceiling needs repaired. Bathroom door is coming off hinges. Door jamb is damaged
and hinges will not screw to jamb. Install new jamb and door.
FAIL R6.A.- Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments: Mold
GENERAL NOTES
Printed on 03/07/2022 7
Page 2 of 4
BARRY STRATTON-03/07/2022 @ 11:54 304.7 Roofs and drainage.The roof and flashing shall be sound,tight and not have
defects that admit rain. Roof drainage shall be adequate to prevent dampness or
deterioration in the walls or interior portion of the structure. Roof drains,gutters and
downspouts shall be maintained in good repair and free from obstructions. Roof water
shall not be discharged in a manner that creates a public nuisance. Gutters leaking
onto porch.
BARRY STRATTON 03/07/2022 @ 11:54 304.10 Stairways,decks,porches and balconies. Every exterior stairway,deck,porch
and balcony,and all appurtenances attached thereto,shall be maintained structurally
sound, in good repair,with proper anchorage and capable of supporting the imposed
loads.
BARRY STRATTON-03/07/2022 @ 11:55 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall
be kept in sound condition,good repair and weather tight
BARRY STRATTON-03/07/2022 a 11:55 305.1 General.The interior of a structure and equipment therein shall be maintained in
good repair,structurally sound and in a sanitary condition
BARRY STRATTON-03/07/2022 @ 11:55 305.4 Stairs and walking surfaces. Every stair,ramp,landing,balcony, porch,deck or
other walking surface shall be maintained in sound condition and good repair.305.5
Handrails and guards. Every handrail and guard shall be firmly fastened and capable of
supporting normally imposed loads and shall be maintained in good condition.
BARRY STRATTON-03/07/2022 @ 11:55 305.6 Interior doors. Every interior door shall fit reasonably well within its frame and
shall be capable of being opened and closed by being properly and securely attached
to jambs, headers or tracks as intended by the manufacturer of the attachment
hardware.
BARRY STRATTON-03/07/2022 @ 11:55 605.1 Installation. Electrical equipment,wiring and appliance
BARRY STRATTON-03/07/2022 @ 11:56 108.1.3 Structure unfit for human occupancy.A structure is unfit for human occupancy
whenever the code official finds that such structure is unsafe,unlawful or,because of
the degree to which the structure is in disrepair or lacks maintenance,is insanitary,
vermin or rat infested,contains filth and contamination,or lacks ventilation,
illumination,sanitary or heating facilities or other essential equipment required by this
code, or because the location of the structure constitutes a hazard to the occupants of
the structure or to the public.
BARRY STRATTON-03/07/2022 @ 11:56 9-7-7: INSPECTIONS REQUIRED: Need to schedule a re-inspection for listed address to
ensure all corrections have been made.8 Months since initial inspection.
Printed on 03/07/20Z: ?1:57
Page 3 of 4
REINSPECTION DATE
04/07/2022
CONTACT SIGNATURE
John Greenly
Signed on:03/07/2022 @ 11:56
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:03/07/2022 @ 11:56
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Printed on 03/07;2022 11 57
Page 4 of 4