HomeMy WebLinkAbout1047 LANGLEY RD (2) Pop - ct.DT) WATERLOO FIRE RESCUE 7 INSPECTION REPORT ) 5j 1047 LANGLEY RD, WATERLOO/A Sti742�/� C)/01—flr)(191/"'62Sg DETAILS SG V—/(--/ Inspection Da -:02/25/_1 Inspection Type: Rental Inspection I Inspection Number:7297 Shi t: N/A I Station N/A Unit: N/A ( Lead Inspector:BARRY STRATTON I Other Inspectors: N/A j Fee:$50.00 P -,TA 5 STATUS CODE DESCRIPTION FAIL 1008.1 -Means of egress Illumination shall be provided in the means of egress in accordance with Section illumination 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. Inspector: BARRY STRATTON-Comments:Egress/exit sign at front entrance the egress light still is not working. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Breaker issue in panel for water heater, FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON -Comments: FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments: FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator, moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:Water heater issues. FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Printed on 02'25/2022 10:24 Page 1 of 3 ^ ~ STATUS CODE DmSCRIPTiON Inspector: BARRvSTRATTON Comments: Holes in walls and window on real-of building isscrewed shut, FAIL R6.A. Interior Structure- Were any Unsafe conditions noted during the interior inspection?(IPIVIC 305.1.1) Unsafe Conditions Inspector: BxRRvSTRATTON Comments:Water heater issues. FAIL R68. Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of68F7(|PM[6O2.2} Inspector: 8ARRvSTRATTON Comments:6O22 Residential occupancies. Dwellings shall be provided with heating facilities capable of maintaining a room temperature of68"F(20"C)in all habitable rooms'bathrooms and toilet rooms based on the winter outdoor design temperature for the locality indicated in Appendix D of the international Plumbing Code. Cooking appliances shall not be used, nor shall portable unvenredfue|'burning space heaters be used, asa means toprovide required heating.Vacant unit onroday'sinspection. FAIL R6I. Mechanica| Eqiupmenc Are mechanical appliances properly installed and maintained in good working condition?(|Px4[Oo3]) Inspector: BARRvSTRATTOm Comments: 505.4 Water heating facilities.Water heating facilities shall be properly installed,maintained and capable of providing an adequate amount of water to be drawn at every required sink lavatory,bathtub, shower and laundry facility aca minimum temperature of11O^F(43"[}.A gas-burning water heater shall not be located in any bathroom,toilet room. bedroom or other occupied room normally kept closed, unless adequate combustion air is provided,An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters. No hot water in unit#3 for the month of December. Need cn Correct ASAP.Z4HR EMERGENCY Repair notice on hot water issue. GENERAL NOTES BARRvSTR/TTON 02/25/2022@ 10:21 189.4Vio|ation penalties.Any person who shall violate a provision of this code,or fail to comply therevvith, or with any of the requirements thereof,shall be prosecuted within the limits provided by state or local laws. Each day that a violation continues after due notice has been served shall be deemed a separate offense. BARRvSTRA77ON 02/25/2022@10:22 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition,These items are still needed for rear entrance. p,m."u""n2izszmz;1`uz+ Page zoro glk • REINSPECTION DATE 03/25/2022 CONTACT SIGNATURE EPM Iowa Signed on:02/25/2022 @ 10:22 INSPECTOR SIGNATURE BARRY STRATTON Signed on:02/25/2022 @ 10:22 QUESTIONS ASOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on C,2 -- 10 Z4 Page 3 of3