3855 W 9TH ST (2)
. 6. 5SL) ' CI -k-h P(2,0 \coop WATERLOO FIRE - SCUE /, � 4�,ER 00 INSPECTION REPORT 12 �0 Pr ,, 1 3855 W 9TH ST, WATERLOO IA S0702 R C.,... ._ S ey i DETAILS Inspection Date:02/24/2022 E Inspection Type: Rental Inspection 1 Inspection Number:7295 ( Shif NI- I Station: N/A Unit: N/A j Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 Af��=G� 4 —? STATUS CODE DESCRIPTION FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments:Front door still not closing within the jamb. FAIL 2015 lFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no and maintenance troubles,supervisory,or alarms)? Inspector: BARRY STRATTON-Comments:Alarm Maintenance still not completed. FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector:BARRY STRATTON-Comments: FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust maintenance systems,and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. Inspector: BARRY STRATTON-Comments: FAIL 901.6.1 -Standards Fire protection systems shall be inspected,tested and maintained in accordance with the referenced standards listed in Table. Inspector: BARRY STRATTON-Comments: Pr.nteo on 02,24 2022 t 14:32 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 901.6.2-Records Records of all system inspections,tests and maintenance required by the referenced standards shall be maintained. Inspector: BARRY STRATTON-Comments: FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Unit#5 shower still not replaced.Wet and damaged drywall not replaced.Tub surround not replaced and ceiling has just been painted over and mold is showing through paint. FAIL R6.A.- Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRY STRATTON-Comments:Mold FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments:Bath Fan GENERAL NOTES BARRY STRATTON-02/24/2022 @ 14:31 403.6 Mold Present In A Rental Unit.a.When mold is found to be visibly present in small amounts, it can be cleaned in a safe and sanitary manner. b.When mold is found in a rental unit and is determined to be a health risk,the building official may order that a clean air report be obtained from a mold specialist approved by the building official. REINSPECTION DATE 03/24/2022 CONTACT SIGNATURE CNC Investments Signed on:02/24/2022 @ 14:31 Z/VAt Printed an 02/2412022©14:32 Page 2 of 3 INSPECTOR SIGNATURE BARRY STRATTON Signed on:02/24/2022 @ 14:32 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Panted on 02 24s2022 L 1432. Page 3 of 3