HomeMy WebLinkAbout1738 FLOWER ST (6) WATERLOO ' ~ ~ ��������������� N��N�E RESCUE &N8PECrIONREPORT \ DOM0NIC 3AMYGEN RENTAL 8^PLEX, 1738 FLOWER Sr,NNATE)tLOO JAS0701 DEvAILS C�~-wc�/\ / _ ��^°� (�dalq C�if w �_Q)9 Inspection Dare:04/27/2822 / Inspection Type: Rental Inspection ] Inspection Number:7556 ( Shift: N/^ | Station: N/A � Unit: N/A | Lead Inspector:BARRY STKATTON I Other Inspectors: N/A I Fee:$50.00 ^��"w� ~,Zos"o STATUS CODE DeScn/PnoN FAIL 101I3 Illumination Exit signs shall be internally or externally illuminated. Exception:Tactile signs required by Section 1013.4 need not be provided with illumination. Inspector: B^RRvSTRATTON Comments:Egress/exit lights still not working FAIL 1025.5 Illumination Where photo}uminescent exit path markings are installed,they shall be provided with not less than 1 footcand|e(11 lux)of illumination for not less than 60 minutes prior co periods when the building is occupied and continuously during the building occupancy. Inspector:BARRYSTRATTUN Comments:Lights still not working in hallways. Several lights Plugged into extension cords running under doors form apartments and some wired into baseboard heaters. FAIL 10312 Re|iabi|icy Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:8ARRYSTRATTON Comments: FAIL 005.1 Abacennent of identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices'appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. /nspecroc BARRY STR/gTUN Comments:Globes are needed on all lights. Lights need to be in working condition.Outlets in unit 2 need repaired since upper portion does not work. Extension cords wired into baseboard heaters need removed.Shop lights from#2 hanging in entryway. Extension cord from unit 4 4 to#3. Printed"""wzr'zozz@,+.uo Page 1 of • STATUS CODE DESCRIPTION FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector: BARRY STRATTON-Comments:Fire doors missing hardware and doors held in open position. FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust maintenance systems,and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. Inspector:BARRY STRATTON-Comments:Alarm still has not been tested and had maintenance. FAIL 901.6.1 -Standards Fire protection systems shall be inspected,tested and maintained in accordance with the referenced standards listed in Table. Inspector: BARRY STRATTON-Comments:Alarm FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E,F, H, I, M,R-1,R-2, R-4 and S occupancies. Exception:In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4. On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARR"STRATTON -Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Smoke detectors missing unit 2 needs smoke detectors in each bedroom and outside of the bedroom.All apartments need to meet this requirement. Units 6,7. 8&3 vacant and destroyed Printed an 04/27/2022 Cr,14.09 Page 2of5 ' STATUS CODE DESCRIPTION ' FAIL R2 Unsafe Equipment Was the presence Of unsafe equipment noted during the inspection?Equipment illay include boilers,heating equipment, elevator,moving stairways,electrical wiring,and flanimab|e liquid containers.(iPk4[ 108.1.2) Inspector:BARnvSTRATTON Comments: FAIL K3 Unfit for Human Is the structure found to be fit for hurnan occupancy according to the code?(I PNIC Occupancy 108.1.3) Inspector: BARRvSTRATTON [ommen,s:: Building is lacking maintenance. 108.1.3 Structure unfit for human occupancy.A structure is unfit for hunian occupancy whenever the code official finds that such structure is unsafe,unlawful or,because of the degree to which the structure is in disrepair or lacks maintenance, is insanitary, vermin or rat infested,contains filth and contamination,or lacks ventilation, illumination'sanitary or heating facilities or other essential equipment required by this oode, or because the location of the structure constitutes a hazard to the occupants of the structure or to the public.Court Order to vacate building. Building tagged Unit to Occupy Do Not Enter. FAIL R4'Exterior Property Areas Is the exterior property area maintained in e dean'safe'and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(|Pm1{302) Inspector: BARRvSTRArTON Comments:Debris all over the rear of the property. FAIL R5 Exterior Structure |s the exterior of the structure maintained in good repair,struocuraUysound and sanitary state?(|PrN[3U4) Inspector:BARRYSTRATTON Comments: FAIL n6 interior strucrure Has the interior nf the structure and equipment inside been maintained in good repair'structurally sound'and in a sanitary cnndition?(|PrwC 305) Inspector: BARRvSTRATTON Comments:Still need new kitchen faucet in unit#2. Exhaust fan in unit#2 need cover.Shower in unit#2 has peeling paint. Doorjarnbs and weather strip still not fixed.Windows are broken oil rear of building.Owner has never requested re'iAspectiontn check completed work. FAIL R6.A. Interior Structure- Were any unsafe conditions noted during the interior inspecrion?(|Pm[3O5.1.1) Unsafe Conditions Inspector: BARRvSTRAlTUN Comments:Exit/egress lights still not working, no fire extinguishers,sanitary conditions of building FAIL R0.8. Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(|PKx[602.2} p^",ed""o4:z-'Z0zz&&`4:09 Page uo,o ~ , . STATUS CODE DESCRIPTION " ^ Inspector:BARRvSTRATTON'Comments: FAIL Ni[ kxechanica| Eqiupmenr Are mechanical appliances properly installed and mainrainedin good working condition?(|PK1COU3.1) Inspector: BARRvSTRATTON Cummems: GENERAL NOTES BxRRvSTRxnrON 04/27/2022@a14:08 Unit#2 and common areas. Units b'7,8'3destroyed B^nRYSTRxTTON 04/27/3822@14:08 112.1 Imminent danger.When, in the opinion of the code official,there is imminent danger of failure or collapse of a building or structure that endangers life,or when any structure or part of a structure has fallen and life is endangered by the occupation of the scrucrure' or when there\s actual or potential danger tothe building occupants or those in the proximity of any structure because of explosives,explosive fumes or vapors or the presence of toxic fumes,gases or materials,or operation of defective or dangerous equipment,the code official is hereby authorized and empowered to order and require the occupants to vacate the premises forthwith.The code official shall cause to be posted at each entrance to such structure a notice reading as follows: "This Structure Is Unsafe and Its Occupancy Has Been Prohibited by the Code Official." It shall be unlawful for any pet-son to enter such structure except for the purpose of securing the structure, making the required repairs, removing the hazardous condition orof demolishing the same BARRvSTRxTTON 04/27/2022@14:09 111.8 Prohibited occupancy.Any occupied structure condemned and placarded by the code official shall be vacated as ordered by the code official.Any person who shall occupy a placarded premises or shall operate placarded equipment,and any owner or owner's authorized agent who shall let anyone occupy a placarded premises or operate placarded equipment shall be liable for the penalties provided by this code. BAnRvSTRATTON O4/27/2OZZCLp14:Og Today's inspection Units 3.6'7.&8destroyed. mE/mspcCnmmmATE os/25/2nZ3 CONTACT SIGNATURE Dominic Tangen Signed on:D4/Z7/2O2Z@14:Uy Printed""04oroo22 @-1*09 Page 4uro INSPECTOR SIGNATURE BARRY STRATTON Signed on:04/27/2022 @ 14:09 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 04/27i2022 1..14 09 Page 5 of 5