RENTAL INSPECTION- 1957 FRANKLIN ST-4-19-22 FOR BILLING INQUIRY: (319)291-4323
I Description I Total Price
REINSPECTION FEE V05 $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
10461 04/28/2022 06/10/2022 2022-00000165 $50.00
Less Prepayment $0.00
Total Due--> $50.00
City of Waterloo
STATUS CODE DESCRIPTION
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Outlets missing covers,outlets wired wrong
in dinning room(bad ground),in basement(hot/neutral reversed), kitchen light not
working,outlet by refrigerator pulling out of wall. Electrical corrections not
completed.
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Need smoke detectors installed to meet
code requirements. Need in each bedroom,outside bedrooms,and in basement.
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Holes in walls in bathroom,mice,bee hives
in windows,broken windows,broken doors,door hardware for back door,and door
to kitchen. Porch door has broken jamb and door does not secure. Plumbing back up
in bathroom and basement.Electric issues with outlets and lights.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments: Need fire safety issues in unit.Smoke
detectors, CO detector,fire extinguisher.
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector: BARRY STRATTON-Comments:Register covers not secured to duct
assembly.
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:No permits or inspections for Power vent
water heater. No permit or inspection done since last inspection.
GENERAL NOTES
Printed on 04 19/2022 ct 10:33
Page 2 of 5
` . ^
8ARRYSTRATTON 04/19/2022@P10:28 109.4 Violation penalties.Any pet-son who shall violate a provision of this code,or fail
to comply therewith,or with any of the requirements thereof, shall beprosecuted
within the|innhs provided by state or local laws. Each day that a violation continues
after due notice has been served shall be deemed a separate offense.
uARRYSTRATToN 04/10/2022@10:28 302.5 Rodent harborage.Structures and exterior property shall be kept free from
rodent harborage and infestation.Where rodents are found,they shall be promptly
exterminated by approved processes that will not be injurious to human health,After
pest elimination, proper precautions shall be taken to eliminate rodent harborage and
prevent neinfestation.(k4ice)
BARRvsTRATTow 04/10/2022@p10:28 304.13 Window,skylight and door frarnes. Every window,skylight,cloor and frame shall
be kept in sound condition,good repair and weather tight.
BARRYSTRATTOW 04/19/2022@10:28 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and
hardware shall be maintained in good condition. Locks at all entrances to dwelling
units and sleeping units shall tightly secure the door, Locks on means of egress cloors
shall bein accordance with Section 70Z.3.
8ARRvsTRATTOw 04/19/2022@10:29 305.6 Interior cloors. Every interior door shall fit reasonably well within its frame and
shall be capable of being opened and closed by being properly and securely attached
to jambs, headers or tracks as intended by the manufacturer of the attachment
hardware.
B«nRv5TRATTON 04/19/2022@�. 10:29 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition. Peeling,chipping,flaking or abraded
paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood
and other defective surface conditions shall becorrected.
BARRYSTRAJT0N 04/19/2022@10:29 300.1 Infestation.Structures shall be kept free from insect and rodent infestation.
Structures in which insects or rodents are found shall be promptly exterminated by
approved processes that will not be injurious to human health.After pest elimination,
proper precautions shall be taken ro prevent reinfestation.
BARRvSTRATTON 04/19y2022@10:29 505.1 General. Every sink,lavatory, bathtub or shower,drinking fountain,water closet
or other Plumbing fixture shall be properly connected to either a public water system
or to an approved private water system. Kitchen sinks' lavatories, laundry facilities,
bathtubs and showers shall be supplied with hot or tempered and cold running water
in accordance with the Plumbing Code.
p,`"teu""vw`mxvzz `ous
Page 3oru
GENERAL NOTES
BARRYSTnxTTOW 04/ gQ02Z @ 10:29 504.3 Plumbing system hazards.Where irisfound that plumbing system in a
structure constitutes hazard ro the occupants orthe structure by reason of
inadequate service,inadequace venting,cross connection, backsiphonage improper
installation,deterioration nr damage or for similar reasons,the code official shall
require the defects to be corrected to eliminate the hazard.(Drain in basement[lot
draining)
eARRYSTRA7TOW 04/19/2022@10:29 9-4-6:WORK REQUIRING PERMIT OR APPROVAL: No building or premises shall tap any
water or sewer main or have installed any private building sewer,water service, private
sewage disposal plant or private water system or have connections,extensions'
replacements,removals or additions of any nature to the sanitary plumbing or water
supply system or disconnection of any fixture or change in the plumbing system
before notifying the plumbing inspector or his assistant and securing a permit or
authority to proceed with the work.(Ord.5392' 3'20'2017)Water heater installed with
oucpermits/inspections.
BARRvSTRxTTON 04/19/2022Co,,�10:30 605.1 Installation. Electrical equipment,wiring and appliances shall be properly
installed and maintained ina safe and approved manner.
8ARRYSTRATTON 04/10/2022@p10:30 701.2 Responsibility.The owner of the premises shall provide and maintain such fire
safety facilities and equipment in compliance with these requirements.A pet-son shall
not occupy as owner-occupant or permit another person to occupy any premises that
dn not comply with the requirements of this chapter.
BARRvSTRAl7ON 04/19/2022@ 10:31 9-7-4 9-7-5: Need updated rent roll for all rental properties for the Clerk's Office.Still
have not received required information per code upon several requests by the City of
Waterloo.
RfxmSPmCTION DATE
OS/17/J82Z
CONTACT SxGmmruRc
LDw PropenjesLL[
Signed oil:U4/1y/2022@lO:31 AL
Printed onwnm�2 11`uo