INSPECTION REPORT
\
DOMINIC TANGEN RENTAL 8.PLEX, 1738 FLOWER ST, WATEKOO JA M701
DETAILS G6
Inspection Date:03/29/20~2
-2
Inspection
Type:�"�=�. t'al I�. ,�p^^e`�"�"�. 1
/ Inspection Number:7444 /A � Station: N/A �
Unit: N/A | Lead Inspector: %A(4z
8ARRv�TR�TTON � �rher|nspectors� NA\ � Fee�$S0�OO ��
mnAnUS CODE DEmCRxPTIOm,
FAI L 1810.1.9 Door operations Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: 8ARRY5TRATTON'Comments:Several doors missing hardware.
Corrections still not done.
FAIL 1018.1 General Aisles and aisle accessways serving as a portion of the exit access in the means of
egress system shall comply with the requirements of this section.Aisles or aisle
accessvvays shall be provided from all occupied portions of the exit access that
contain seats,tables,furnishings, displays and similar fixtures or equipment.The
minimum width o/'required capacity of aisles shall be unobstructed. Exception:
Encroachments complying with Section 1005.7.
Inspector: BARRY STRATTON-Comments:Egress/exit lights not working. Lights and
signage still not working
FAIL 1031.2 Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or ocher
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
|nspeccocBARRvSTRATTON Comments:
FAIL 1031.7 Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
ernergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars'grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of key'tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRYSTRATTDN Comments: Broken windows need replaced. Broken
windows in exit discharge doors frames on real-of building.
Printed""nazeo022zCW`z:4`
Page of
,
S TA TUm CODE DESCRIPTION
FAIL 585.1 Address identification New and existing buildings shall be provided with approved address identification.
The address identification shall be legible and placed in a position that is visible from
the street or road fronting the property.Address identification characters shall
contrast with their background.Address numbers shall be Arabic numbers or
alphabetical letters. Numbers shall not be spelled out. Each character shall be not
less than 4 inches(102mm)high with aminimum stroke width of1/2(127mm).
Where required by the fire code official,address identification shall be provided in
additional approved locations to facilitate ernergency response.Where access is by
means of a private road and the building cannot be viewed frorn the public way,a
monument,pole or other sign or means shall be used to identify the structure.
Address identification shall bemaintained.
Inspector:BARRYSTRATTON Comments:Unit numbers need robe listed on
apartment door
FAIL 605.1 Abatement of identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
darnaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRYSTK/TTON Comments:Electric panel cover in unit#3needs
secured. Outlets missing covers. Lights missing globes. Multi plug adapters need
removed. Exhaust fan above stove has exposed wires.Outlets not working. Extension
cords to lights running under-door to common hallway,Also extension cords wired
into baseboard heaters
FAIL 901.6 Inspection,testing and Fine detection,alarm,and extinguishing systems,mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective. wonrequiredfire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector: BARRvSTRATTON Comments:Alarm testing and maintenance still not
done.
FAIL 906 1 Where required Portable fire extinguishers shall beinstalled in all of the following locations: 1. In new
and existing Group A. B' E' F, H' |' K4. R-1,R'J' R'4and Soccupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum raring of 1'A: 1O-8:C. 2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4. On each floor of structures under
construction,except Group R'3oocupancies' in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table y06.1.6.Special-hazard areas'
including but not limited to laboratories,computer-rooms and generator rooms,
where required by the fire code official.
Inspector: BARRYSTR/TTON Comments:
"-".^^=ovamzoz'o`'^`
` .
STATUS CODE DESCRIPTION _
FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
mu|tip|e'oatinnsrnoke installed in accordance with Sections yU7.2.11.1 through 007.2.11.6 and NFPA72.
alarms
Inspector: BARRvSTRATTON Comments: Need smoke detectors installed ineach
bedroom and outside nf the bedrooms.
FAIL R2 UnsafeEquipmenz Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment, elevator, moving stairways,electrical wiring,and
flammable liquid containers.(|PMC 108.1.2)
inspector:BARRYSTRATTON Comments:Water leaking into electric pane. Need
licensed professional to check panel and breakers for water damage.604.3.1
Abatement of electrical hazards associated with water exposure.The provisions of
this section shall govern the repair and replacement of electrical systems and
equipment that have been exposed rowater
FAIL R4 Exterior Property Areas Is the exterior property area maintained in a dean'safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(|PK4[382)
Inspector:BARRvSTRATTON Comments:Concrete block not/epain*d]unkand
debris all over property. Illegal burning at rear of listed address.
'
FAIL R5 Exterior Structure Is the exterior of the struoure maintained in good repair'structurally sound and
sanitary state?(|Pw1[304)
Inspector:BARRYSTRAJTON Comments
FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and ina sanitary condition?(|PM[385)
Inspector: BARRYSTRATTON Comments: Black mold,fire safety items not addressed,
exit/egress lights not addressed, broken windows,common area floors,&alarm Unit
#3 is destroyed inside apartment.Apartments 6,7, &8 upstairs all not secured and
destroyed on the interior of apartments.
FAIL R6.A. Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: 8ARRYSTRATTON Comments:Ceiling in kitchen has water leak.
Mechanical closet in bedroom has large water leak. Black mold on walls. Damaged
drywall needs removed and replaced. Living ronm windows leaking water. Doors
missing hardware.
FAIL R6.B. Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of68F7(|PK4[OO2.2)
Printed""m000m,Cc`z^,
Page om5
STATUS CODE DESCRIPTION
Inspector:BARRY STRATTON-Comments: Furnace needs maintenance in Unit#3
FAIL R6.C.- Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:Supply lines to water heater not installed to
code.Stove has broken handle and burners not working.
GENERAL NOTES
BARRY STRATTON-03/29/2022 @ 12:37 Unit#3 and common areas Also on today's inspection 6,7, &8 unsecured.
BARRY STRATTON-03/29/2022 @ 12:38 604.3 Electrical system hazards.Where it is found that the electrical system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate service,improper fusing, insufficient receptacle and lighting outlets,
improper wiring or installation,deterioration or damage,or for similar reasons,the
code official shall require the defects to be corrected to eliminate the hazard.604.3.1
Abatement of electrical hazards associated with water exposure.The provisions of this
section shall govern the repair and replacement of electrical systems and equipment
that have been exposed to water
BARRY STRATTON-03/29/2022 @ 12:38 9-7-6: DENIAL,SUSPENSION,REVOCATION OR NONRENEWAL:A.Grounds:The licensing
officer or building official may revoke,suspend,deny or decline to renew any landlord
license issued under section 9-7-4 of this chapter or any rental registration permit
issued under section 9-7-5 of this chapter for any of the following grounds:3. Failure to
correct deficiencies noted in notices of violation within the time specified in the notice.
Court Order still not complied with.(Contempt)
BARRY STRATTON-03/29/2022 @ 12:38 111.1.3 Structure unfit for human occupancy.A structure is unfit for human occupancy
whenever the code official finds that such structure is unsafe, unlawful or, because of
the degree to which the structure is in disrepair or lacks maintenance,is insanitary,
vermin or rat infested,contains filth and contamination,or lacks ventilation,
illumination,sanitary or heating facilities or other essential equipment required by this
code,or because the location of the structure constitutes a hazard to the occupants of
the structure or to the public.
Printed on 03r29 2 __-_12:4'
Page 4 of 5
. ' . .
GENERAL NOTES
BAxRYsTnA7TON 02/29/2022@12:39 112.1 Imminent clanger.When, in the opinion of the code official,there is imminent
danger-of failure or collapse of a building or structure that endangers life,or-when any
structure or part of a structure has fallen and life is endangered by the occupation of
the structure, or when there is actual o/potential danger to the building occupants or-
those incheproximbyofanystrucrurebecauseofexp|osives,exp|osivefumesor
vapors or-the presence of toxic fumes,gases or materials,or-operation of defective or
dangerous equipment,the code official is hereby authorized and empowered to order
and require the occupants to vacate the premises forthwith.The code official shall
cause to be posted at each entrance to such structure a notice reading as follows:
"This Structure Is Unsafe and Its Occupancy Has Been Prohibited by the Code Official."
It shall be unlawful for any person to enter-such structure except for-the put-pose of
securing the structure, making the required repairs, removing the hazardous
condition orof demolishing the same.
8ARRY5TRx7T0N 03/29/2022 12:41 109.4Vio|ation penalties.Any pet-son who shall violate a provision nf this code,orfail
to comply therewith, or-with any of the requirements thereof, shall be prosecuted
within the limits provided by state or local laws. Each day that a violation continues
after-due notice has been served shall be deemed a separate offense
me/mSPEcr/mmoArE
O4/27/3U22
CONTACT SIGNATURE
Dominic Tangen
Signed on:O3/2g/2U22@p12:40
INSPECTOR SIGNATURE
uARRYSTRAlTON -
S|�ned on:O3/Zy/2O220�1Z:4U �- \
/