INSPECTION REPORT
DOMINIC TANGEN R8NTALQ-PLEX, 1738 FLOWER ST, WATERLOO IA 50701 w��"��
DETAILS _lal
/9
Inspection Date:O4/Z7/20Z2 | Inspection Type: Rental inspection I Inspection Number:755 N/A tadon: N/A �
Unit: N/A Lead Inspector: 8ARKYSTR/ATON Other Inspectors: N/A | Fep:$S0.U0
STATUS Cwoe oESca/*nmm
FAIL 1010.1.0 Door operations Except as specifically permitted by this section,egress doors shall be readily
openab|e from the egress side without the use ofa key or special knowledge nr
effort.
Inspector: BARRYSTRATTUN Comments:Several doors missing hardware and
corrections not done.Unit isdestroyed.
FAIL 101S.1 General Aisles and aisle accessways serving as a portion of the exit access in the means of
egress systern shall comply with the requirements of this section.Aisles or aisle
accessways shall be provided from all occupied portions of the exit access that
contain seats'tables,furnishings'displays and similar fixtures or equipment.The
minimum width or required capacity of aisles shall be unobstructed.Exception:
Encroachments complying with Section 18U5.7.
Inspector: BARRYSTRATTON Comments:Egress/exit lights not working. Lights and
signage still not working
FAIL 11031.2 Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRvSTRxTTON Comments:
FAIL 1031.7 Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction,and the following: Required
ernergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars'grilles,grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key,tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: 8ARRYSTRATTON Comments:Broken windows need replaced. Broken
windows in exit discharge doors frames on rear of building,
Printed""nwzr/zoo�-&-`^oo
Page 1nro
^ -
'
STATUS CODE DESCRIPTION
FAIL 505.1 Address identification New and existing buildings shall be provided with approved address identification.
The address identification shall be legible and placed in a position that is visible from
the street or road fronting the property.Address identification characters shall
contrast with their background.Address numbers shall be Arabic numbers or
alphabetical letters. Numbers shall not be spelled out. Each character shall be not
less than 4 inches(1U2mm)high with aminimunn stroke width of1/2(12.7mm).
Where required by the fire code official,address identification shall be provided in
additional approved locations to facilitate emergency response.Where access is by
means of a private road and the building cannot be viewed from the public way,a
monument,pole or other sign or means shall be used to identify the structure,
Address identification shall bemaintained.
Inspector: 8ARRvSTRATTON Comments:Unit numbers need cobe listed on
apartment door
FAIL 605.1 Abatement of identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not beused.
Inspector: BARRvSTRATTUN Comments:Electric panel cover in unit#3needs
secured. Outlets missing covers.Lights missing globes. Multi plug adapters need
removed. Exhaust fan above stove has exposed wires.Outlets not working. Extension
cords to lights running under door to common hallway.Also extension cords wired
into baseboard heaters
FAIL 901.6 Inspection,testing and Fire detection,alarm,and extinguishing systerns,mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector: sARnvsTRATTOm [oonnetits:Alarm testing and maintenance still not
done.
FAIL 906.1 Where required Portable fire extinguishers shall be installed in all uf the following locations: 1. in new
and existing Group A. B' E'F, H' |' rW. R'1'R'2' R'4 and Soccupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in items 2 through 6 where each dwelling unit is provided with a pot-table
fire extinguisher having a minimum rating of 1`A: 1U'8:C.2.Within 30 feet(0144 nnm)
of commercial cooking equipment.3. In areas where flarnmable or combustible
liquids are stored, used or dispensed.4. Un each floor of Structures under
construction,except Group R'3 occupancies,in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 006.1.6. Special-hazard areas,
including but not limited to laboratories, computer rooms and generator rooms'
where required by the fire code official.
Inspector:BARRvSTRATTON Comments:
~,,".°"""o+z---z'- ,-oo
Page zofu
STATUS CODE oEscm/pnom
FAIL 0072.11 Single and Listed single-and multiple-station smoke alarms complying with UL217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through y07.Z.11/i and NFPA%L
alarms
Inspector:B4RRYSTRATTON Comments: Need smoke detectors installed ineach
bedroom and outside nf the bednooms.
FAIL R2 unsafeEquipmenc Was the presence Of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator,moving stairways,electrical wiring,and
flarnmab\e liquid containers.(|PN1[188.1.2)
Inspector: BARRvSTRATTOw Comments:Water leaking into electric pane. Need
licensed professional to check panel and breakers for water damage.604.3.1
Abatement of electrical hazards associated with water exposure.The provisions of
this section shall govern the repair and replacement of electrical systems and
equipment that have been exposed tnwater
FAIL R4 Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(|Pk4[3U2)
Inspector: BARRYSTRATTON Comments:Concrete block not repaired junk and
debt-is all over property. Illegal burning ar rear of listed address
FAIL n5 Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(|PK4[3O4)
Inspector:8ARRYSTRATTow Comments:
FAIL R6 Interior Structure Has the interior of the structure and equiprnent inside been maintained in good
repair,structurally sound,and ina sanitary condition?(|PM[3U5)
Inspector:BARRvSTR*JT0N Comments: Black mold,fire safety items not addressed,
exit/egress lights not addressed, broken windows,common area floors,&alarm Unit
#3 is destroyed inside apartment.Apartments 6,7,&8 upstairs all not secured and
destroyed on the interior of apartments.Water leak in unit6.
FAIL RS.& Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: 8ARRYSTRAJTOm Comments:mi|ingin kitchen has water leak. Mechanical
closet in bedroom has large water leak.Black mold on walls. Damaged drywall needs
removed and replaced. Living room windows leaking water. Doors missing hardware.
FAIL R6.8. Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of68F?(|Pw1[6OI2)
Printed""wv,n202zm`4:00
Page oo,u
STATUS CODE
oESca/Pnmm
inspector:BARRvSTRATTON Comments:
FAIL R6.[. K4echanica\Eqiupment Are mechanical appliances properly installed and maintained it)good working
oondidon?(|pmC 60I1)
inspector: BARRYSTRAlTUN Comments:Supply lines cn water heater not installed to
code,Stove has broken handle and burners not working.
GENERAL NOTES
aARRvsTRATTON 04/27/2022@13:57 Unit#3 and common areas Also oil today's inspection O'7'&8unsecured.
BAnRYSTR/gTON 04/27/2022@13:57 111.1.3 Structure unfit for human occupancy.A structure is unfit for human occupancy
whenever the code official finds that such structure is unsafe,unlawful or,because of
the degree to which the structure is in disrepair or lacks maintenance,is insanitary,
vermin or rat infested,contains filth and contamination,or lacks ventilation,
illumination,sanitary or heating facilities or other essential equipment required by this
code,or because the location of the structure constitutes a hazard to the occupants of
the structure nrto the public.
aARnvSTnxTTOw'84/27/2OZ2@13:58 111.8 Prohibited occupancy.Any occupied structure condemned and placarded by the
code official shall be vacated as ordered by the code official.Any person who shall
occupy placarded premises or shall operate placarded equipment,and ally owner or
owner's authorized agent who shall let anyone occupy a placarded premises or
operate placarded equipment shall be liable for the penalties provided by this code
nE/mspcCnommArc
85/25/2O22
CONTACT SIGNATURE
oomlinicTangen
Signed on:O4/Z7/2O22@p13:5g
INSPECTOR S*smArmms
BARRYSTnATToN
Signed on:D4/27/2U22 @13:59
Printed onnw27/2voCa.`4im
Page*mo