RENTAL INSPECTION- 1202 W 2ND ST-4-8-22 FOR BILLING INQUIRY: (319)291-4323
L Description Total Price
REINSPECTION FEE $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23001 04/28/2022 06/10/2022 2022-00000176 $50.00
Less Prepayment $0.00
Total Due-* $50.00
City of Waterloo
-f19 °' ue
WATERLOO FIRE RESCUE a C1'3`.' 4 4�
INSPECTION REPORT
QUALITY CONCRETE MULTI-RESIDENTIAL RENTALS, 1202 W 2ND ST, WATERLOO IA 50701 4410
DETAILS
Inspection Date:04/08/2022 I Inspection Type: Rental Inspection I Inspection Number:7499 I Shift: N/A I Station: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A j Fee:$50.00 ii"r /e,t itz, - 5 ''
STATUS CODE DESCRIPTION
FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of
egress system shall comply with the requirements of this section.Aisles or aisle
accessways shall be provided from all occupied portions of the exit access that
contain seats,tables,furnishings, displays and similar fixtures or equipment.The
minimum width or required capacity of aisles shall be unobstructed.Exception:
Encroachments complying with Section 1005.7.
Inspector:BARRY STRATTON-Comments:
FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:BARRY STRATTON-Comments:Doors and jambs broken
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments: Missing globes, Electric panel blocked and
appliances in basement.
Printed on 04/0312022,L 11.34
Page 1 of 6
xrmrwS CODE DESCRIPTION
FAIL 703.1 Maintenance The required fire-resistance rating of fire-resistance-rated construction,including,
but not limited to,walls,firestops, shaft enclosures, partitions,smoke barriers,
floors'fire'resiszive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained. Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where damaged, altered, breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed, such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of a panel,access door,ceiling tile or similar
movable entry tothe space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire.Openings through fire-resista nce-rated assemblies shall be protected by
self-or automatic-closing doors of approved construction meeting the fire protection
requirements for the assembly.
Inspector:8ARRYSTR/QTON Comments:Ceiling in living room still not fixed.Water is
still leaking in living roorn.Walls damaged frorn water and floor has been removed
where mold and water damage occurred. Holes in walls not corrected.
FAIL 086.1 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group x.8' E' F, H' \' rw'R-1' n'2. R'4 and Soccupancies. Exception: In
Group R-2 occupancies, pot-table fire extinguishers shall be required only in locations
specified in items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum razing of 1'A: 1O'8:C.2.Within 30 feet(0144 mm)
of commercial cooking equipment.3. |n areas where flammab|eorcombustible
liquids are stored, used or dispensed.4. On each floor of structures under
construction,except Group R-3 Occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.5.Special-hazard areas,
including but not limited to laboratories, computer rooms and generator rooms,
where required by the fire code official.
Inspector: QARRvSTRxTTON Comments:
FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
mu|tip|e'stationsmoke installed in accordance with Sections 0O7.Z.11.1 through y87.2.11.B and NFPA72.
alarms
Inspector: BARRvSTRATTUN Comments:Smoke detectors need robe installed tn
meet current rental requirements.
FAIL 915.1 General Carbon monoxide detection shall be insTalled in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.0.
mspectocBxRRvSTRATTON Comments:[O Detector needed.
FAIL R1 unsafe Scrucrures |s the structure found to be dangerous znthe life,health,property or safety of either
the public or occupants of the structure?(|PK4[ 1O8.1.1)
Printed on 04/0&2022(�!n.34
Page zorm
` ^
STATUS coal DESCRIPTION
Inspector: 8ARRvSTRATTON Comments:Ceiling in living room and fallen, roof
leaking, no maintenance to apartments'mold. Holes in walls from water damage.
FAIL R3 Unfit for Human Is the structure found to be fit for hurnan occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRvSTRATTON Comments:Ceiling in living room and fallen,roof
leaking,no maintenance to apartments,mold. Holes in walls from water darnage.Will
need inspected before being rented.
FAIL R4 Exterior Property Areas is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds, and pest
infestations.(IPrwc3V2)
Inspector: BAnRvSTRxTTON Comments: Debris
FAIL ns Exterior Structure |s the exterior of the structure maintained ingood repair, sr/'ucruraUy sound and
sanitary state?(IPm1[3U4)
Inspector:BARRYSTRATT0N Comments: Deck stairs and landing still not corrected
and are still unsafe.
FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and ina sanitary condition?(|PK4[305)
Inspector: BARRvSTR/QTON Comments:Entry door needs replaced.jamb and door
are broken. Broken windows need replaced. Egress path is blocked inkitchen
because refrigerator is blocking path. Ceiling in living room has collapsed.Ceiling tiles
are damaged by water leak.bath sink is not secured to wall in bathroom.Sewer leak
in basement needs repaired by licensed professional.Screen door does not have ally
door hardware. Back door to 1202 did not function because tenant advised it is
broken.Security hardware to keep door secured in jamb is broken and jamb not
capable ro keep door secured and weather tight.
FAIL R6.^. Interior Structure- VVere any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector: BARRY STRATTON-Comments: Mold,egress,and currently stove being
used to heat apartment because furnace does not work,
FAIL R6.[ K4echanica|Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(|Pk4[6UI1)
Inspector:BARRYfJKATTON Comments: Furnace can not maintain 68degreeswith
all the broken windows in building.Maintenance to furnace needed and new windows
need installed inbuilding.
wm"*onowomzmzL&,,u^
Page aorm
, ~
GENERAL NOM
BARRvSTRAlTON'O4/O&O022@11:3U 108.1.3 Structure unfit for human occupancy.A structure is unfit for human Occupancy
whenever the code official finds that Such structure is unsafe,unlawful or,because of
the degree cowhich the structure is in disrepair orlacks maintenance' is insanitary,
vermin or rat infested'contains filth and contamination,or lacks ventilation,
illurnination,sanitary or heating facilities or other essential equipment required by this
code,or because the location of the structure constitutes a hazard to the occupants of
the structure orto the public.
DARRYSTRATTON 04/08/2022@11:30 108.1.2 Unsafe equipment.Unsafe equipment includes any boiler,heating equipment,
elevator, moving stairway,electrical wiring ur device'flannmab|e liquid containers or
other equipment on the premises or within the structure which is in such disrepair or
condition that such equipment is a hazard to life, health,property or safety of the
public or occupants of the premises or structure. Furnace not working and stove being
used for heat source.
BARRY5TRATTON 04/08/2022@11:31 108.1.1 Unsafe structures.An unsafe structure is one that is found to be dangerous to
the life, health,property or safety of the public or the occupants of the structure by
not providing minimum safeguards to protect or warn occupants in the event of fire,
or because such structure contains unsafe equipment or is so damaged,decayed,
di|apidaced,structurally unsafe or of such faulty construction or unstable foundation'
that partial or complete collapse is possible. Building is uninhabitable in current
condition.
BARRvsTRxTTON 84/08/2022@1131 302.1 Sanitation. Exterior property and premises shall be maintained in a clean,safe
and sanitary condition.The occupant shall keep that part of the exterior property that
such occupant occupies or controls ina clean and sanitary condition.
BARRvSTRA7TON O4/OQ/2Q2Z@, 11:31 304.15 Doors. Exterior doors,door assernblies, operator systerns if provided,and
hardware shall be maintained in good condition. Locks etall entrances codwelling
units and sleeping units shall tightly secure the door. Locks on means of egress doors
shall be in accordance with Section 702.3.All interior cloors/jambs and all exterior
doors/jambs.
BARRvSTRATTDN O4/DB/2OZ2 Ca, 11:31 304.10 Stairways,decks,porches and balconies. Every exterior stairway,deck,porch
and balcony,and all appurtenances attached thereto,shall be maintained structurally
sound, in good repair,with proper anchorage and capable of supporting the imposed
loads
BARRYSTRxQTON 04/08/2022@11:32 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and
capable of supporting normally imposed loads and shall be maintained ingood
condition.
,�°u""owvm2022��`,y+
Page 4urm
'
GENERAL NOTES
BARRYSTRATTON 04/08/2022@11:32 304.13 Window,skylight and door frarnes. Every window,skylight, door and fran-ie shall
be kept in sound condition,good repair and weather tight.
BARnv STeATTON 04/08/2022 Ca) 1 1:s2 305.2 Structural members.Structural members shall be maintained structurally sound,
and be capable of supporting the imposed loads.
BARRYSTRAlTON 04/08/2022@p11:32 305.3 Interior surfaces. interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition. Peeling,chippin��ahingorabraded
paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood
and other defective surface conditions shall becorrected.
�ARnY5TRATTON 04/03/2022@11:32 308.1 Accumulation of rubbish or garbage. Exterior property and prernises,and the
interior-of every structure,shall be free from any accumulation of rubbish or garbage.
(Basement)
BARRvSJRATTON 04/08/2022@11:32 504.1 General. Plumbing fixtures shall be properly installed and maintained inworking
order,and shall be kept free frorn obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition.
BARRYSTRA7TON 84/08/2022@P11:33 702.1 General.A safe,continuous and unobstructed path of travel shall be provided
from any point in a building or structure to the public way. Means of egress shall
comply with the international Fire Code.
ma»msPECr/mmaArE
U5/O3/2032
cmmmuCTx16NATURE
Quality Concrete Construction /�--
Signed on:04/88/2022 @ 1 1:33
INSPECTOR SIGNATURE
8ARRvSTRATTON ^~-----
Signed on:04/0O/202]@o11:33
Printed onowom 11:34