Loading...
HomeMy WebLinkAbout1411 W 6TH ST (2) �;��� INVOICE DATE DUE DATE INVOICE# TOTAL DUE //::� Ili. /Ii Fri ter•% 04/28/2022 06/10/2022 2022-00000180 $50.00 Customer#: 12490 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable METRO INVESTMENTS 715 Mulberry St 2117 FALLS AVE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1411 W 6TH ST- 3-9-22 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price REINSPECTION FEE $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12490 04/28/2022 06/10/2022 2022-00000180 $50.00 Less Prepayment $0.00 Total Due — $50.00 City of Waterloo --)�1 ` rN ,i)tss3 WATERLOOFIRE RESCUEr:C: PJ 3 `.� 4: S INSPECTION REPORTNn , > 1411 W i6TH T, WATERLOO IA 50702 44 DETAILS Inspection Date:03/09/2022 [ Inspection Type: Rental inspection 1 Inspection Number:7350 I Shift: A I Station: N/A Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A Fee:$50.00 / d _ STATUS CODE DESCRIPTION FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction,and the following:Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools.Bars,grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON-Comments:Broken windows upstairs. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B,E,F,H,I,M,R-1,R-2,R-4 and S occupancies.Exception:In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3.In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shalt be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NEPA 72. alarms Inspector:BARRY STRATTON-Comments:Smoke detectors needed in each bedroom, outside bedrooms,and in basement. FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator, moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector:BARRY STRATTON-Comments:Drain pipe in basement to sanitary stack not installed to code.Shower needs repaired for leaks. Printed an 03/09/2022 t 1:08 Page 1 of 3 t STATUS CODE DESCRIPTION FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector:BARRY STRATTON-Comments:Roof/gutters and drainage into basement. Snow melting and basement has water. FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector:BARRY STRATTON-Comments:Foundation FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Several leaks in basement.Leaks from foundation. Plumbing leaks and water valve for outside faucet is leaking into basement.Shower leaking into basement through floor.Water leaking onto bathroom floor from shower. Need handrails to upstairs. Broken windows upstairs need fixed.Sewer gas smell in basement. Drain pipe in basement not secured to code.Wire hanger rapped around electric conduit not allowed. Drain pipe appears to go nowhere. Floor in bathroom need repaired from water damage.Ceiling in basement under bathroom damaged from water.Bedroom wall paneling pulling away from wall needs repaired.Today's inspection the kitchen sink is now backed up. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector:BARRY STRATTON-Comments:Potential for mold to form with all water leaks.Mold on upstairs walls from water damage. GENERAL NOTES BARRY STRATTON-03/09/2022 @ 11:04 304.5 Foundation walls.Foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests. BARRY STRATTON-03/09/2022 @ 11:05 304.7 Roofs and drainage.The roof and flashing shall be sound,tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains,gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance Printed an 03/09/2022 08 Page 2 of 3 GENERAL NOTES BARRY STRATTON-03/09/2022 @ 11:05 504.1 General. Plumbing fixtures shall he properly installed and maintained in working order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe,sanitary and functional condition. BARRY STRATTON-03/09/2022 11:05 403.6 Mold Present In A Rental Unit.a.When mold is found to be visibly present in small amounts, it can be cleaned in a safe and sanitary manner. b.When mold is found in a rental unit and is determined to be a health risk,the building official may order that a clean air report be obtained from a mold specialist approved by the building official. REINSPECTION DATE 04/11/2022 CONTACT SIGNATURE Metro INvestments LLC ,-7,1 J� Signed on:03/09/2022 @ 11:06 I� INSPECTOR SIGNATURE BARRY STRATTON Signed on:03/09/2022 @ 11:06 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 03/091"20:: 11:03 Page 3 of 3