Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRYME TYME-626 SYCAMORE ST
OF WA 7-4" INVOICE DATE DUE DATE INVOICE# TOTAL DUE A �'( 08/20/2026 09/25/2026 2027-00000083 $200.00 o . • I 'n ...• 1 0 Customer#: 24658 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable PRYME TYME 715 Mulberry St 626 SYCAMORE ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 626 SYCAMORE ST-08/18/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 3 $200.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24658 08/20/2026 09/25/2026 2027-00000083 $200.00 Less Prepayment $0.00 Total Due —* $200.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street Pryme Tyme-626 Sycamore ST,BLDG 626 Sycamore St,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0811812026 Annual Inspection(1Yr) (REINSPECTION ] c� nt0 20185-R8 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 0 0 0 7 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 09/16/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0811812026 @ 15:33 $200 re-inspection fee for failure to complete corrections as of 8118126.Met with Rodney today,he confirmed no repairs have been completed.Complete corrections to avoid fees at following inspections. BRAD BALDWIN-0712212026©13:05 S200 re-inspection fee for failure to complete corrections on scheduled 6125126 inspection.Complete all correction to avoid fees at following inspections. BRAD BALDWIN-0712212026 @ 13:05 $150 re-inspection fee,failure to complete corrections as of 4116126.Complete corrections to avoid possible fees at following inspections BRAD BALDWIN-0712212026 @ 13:05 Withholding re-inspection fee today,complete corrections to avoid possible fees at later inspections. BRAD BALDWIN-07/22/2026 @ 13:05 •$80 annual inspection fee BRAD BALDWIN-07122/2026 @ 13:05 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07/22/2026 @ 13:05 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-07122/2026 @ 13:05 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.**•**Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-07/2212026 @ 13:05 $100 re-inspection fee,failure to complete corrections as of 3/19/26. GENERATED ON 8/18/28, 3:34 PM 1 of 7 BRAD BALDWIN•07/2212026 @ 13:05 S200 reinspection fee,failure to complete corrections as of 518126.Phone calls with Keaton and Rodney on 5/8126,Cedar Valley Handyman is scheduled to make remaining necessary repairs but has not visited the site to do so yet. BRAD BALDWIN-07122/2026 @ 13:05 S200 re-inspection fee for failure to complete corrections on 613126 inspection.Phone call with Randy&Keaton today to address lack of progress,liquor license will not be approved till fire inspection is complete. BRAD BALDWIN-07122/2026 @ 13:05 S200 re-inspection fee for failure to complete corrections 7/22126.Complete all correction to avoid fees at following inspections and possible denial of alcohol license. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Rodney Lewis Date: BRAD BALDWIN 08118/2026 CHECKLISTS GENERATED ON 8/18/26, 3:34 PM 2 OF 7 Reinspection S: tus Code Description Fail 1013.1-Where required. Exits and exit access doors shall be marked by an approved Location:Near bathrooms exit sign readily visible from any direction of egress travel. Comments:Exit sign shall be turned 90 degrees to direct egress The path of egress travel to exits and within exits shall be towards alley exit between bathrooms. marked by readily visible exit signs to clearly indicate the direction of egress travel in cases where the exit or the path of egress travel is not immediately visible to the occupants. Intervening means of egress doors within exits shall be marked by exit signs.Exit sign placement shall be such that any point in an exit access corridor or exit passageway is within 100 feet(30 480 mm)or the listed viewing distance of the sign,whichever is less,from the nearest visible exit sign. Exceptions:1.Exit signs are not required in rooms or areas that require only one exit or exit access,2.Main exterior exit doors or gates that are obviously and clearly identifiable as exits need not have exit signs where approved by the fire code official.3.Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1,R-2 or R-3.4.Exit signs are not required in dayrooms,sleeping rooms or dormitories in occupancies in Group 1-3.5.In occupancies in Groups A-4 and A-5,exit signs are not required on the seating side of vomitories or openings into seating areas where exit signs are provided in the concourse that are readily apparent from the vomitories. Egress lighting is provided to identify each vomitory or opening within the seating area in an emergency. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:High bay egress lights illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Provide documentation of testing lights including repairs made if necessary confirming working properly.Document shall include address,date and signed,email to inspector. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Basement(west of stairs) prohibited.Approved covers shall be provided for all switch Comments:Install cover on box and electrical outlet boxes. itt: .011, 14‘1) \ r as L :; 3 r' effik GENERATED ON 8/18/28, 3:34 PM 3 of 7 Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Bar connected to a permanently installed receptacle.Exceptions: Comments:Power strip plugged to another power strip at front of bar 1.Where approved for use in a Group A occupancy or in a shall be corrected.All power strips shall plug directly to wall outlets meeting room in a Group B occupancy,not more than five for light duty electric only. relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. h4 Ey' I • I GENERATED ON 8/18/28, 3:34 PM 4 OF 7 Fail 701.5-Maintaining protection. Materials,systems and devices used to repair or protect Location:Bathroom hallway breaches and openings in fire-resistance-rated construction Comments:Obtain permit and inspection to install rated fire door to and construction installed to resist the passage of smoke neighboring space,currently plywood covering door opening. shall be maintained in accordance with Sections 703 through 707. I is C 6 5 OF 7 GENERATED ON 8/18/26, 3:34 PM Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Ceiling materials and systems used to protect joints and voids in the Comments:Obtain permit and inspection and repair hole in ceiling. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer&;#039;s installation instructions. ia -,F^ Fail 901.4.6-Appearance of equipment. Any device that has the physical appearance of life safety or Location:Smoke detectors fire protection equipment but that does not perform that life Comments:All smoke detectors in building shall be maintained as safety or fire protection function shall be prohibited. working properly.Noted detectors beeping and covers off today 1/27126. GENERATED ON S/18/26, 3:34 PM 6 OF 7 • Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $200.00 Invoice Number Check Number Transaction Number NIA NIA N/A GENERATED ON 8/18/28, 3:34 PM 7 OF 7