Loading...
HomeMy WebLinkAboutSTAPLES-1542 FLAMMANG DR OF W A 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE o 08/20/2026 09/25/2026 2027-00000085 $100.00 .. . / et. 1mi • -in I 1111111.1 I I T—'�`T 0 4S 7v10‘� Customer#: 4709 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable STAPLES 715 Mulberry St PO BOX 9263 WATERLOO, IA 50703 FARMINGHAM, MA 01712 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1542 FLAMMANG DR- FOR BILLING INQUIRY: (319)291-4323 08/12/2026 Description Total Price INSPECTION 2,000 HH $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4709 08/20/2026 09/25/2026 2027-00000085 $100.00 Less Prepayment $0.00 Total Due—> $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. ?,,„„,`* Waterloo Fire Rescue Inspection Report 425 E.3rd Street Staples-1542 Flammang DR,BLDG 1542 Flammang Dr,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type f� Inspection Number 0811212026 Annual Inspection(1Yr) Inn J 10 1043 Lead Inspector Shift Station Unit BRAD BALDWIN N/A N/A NIA Other Inspectors NIA SUMMARY OF INSPECTION 038 k� 22 ® 25 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 09/14/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0811212026 @ 15:18 c •$3.10 annual inspection fee BRAD BALDWIN-08/12/2026 @ 15:18 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-08/1212026 @ 15:19 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-08/12/2026 @ 15:28 Annual fire alarm and sprinkler system inspections due by 9117/26.Reports of inspections required to be uploaded to Compliance Engine including deficiencies repaired. BRAD BALDWIN-08/1212026 @ 15:31 Fire extinguishers due annually serviced by September 2026. BRAD BALDWIN-08113/2026 @ 07:02 Corrected on site during 8112126 inspection:Removed laminator equipment from extension cord and cord was removed from walkway.Laminator shall plug to a permanent outlet,adding a new outlet requires a licensed electrical contractor to obtain permit and inspection. SIGNATURES Contact signature Inspector signature No signature Report completededpost ostinspection GENERATED ON 8/13/28, 7:42 AM 1 OF 11 General Manager(Brooke)2026 Date: BRAD BALDWIN 0811312026 CHECKLISTS Means of Egress stain. code Description Fail 1032,2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Exit hallway near manager's officeibreakroom continuously maintained free from obstructions or Comments:Remove all items and storage in hallway,all portions of a impediments to full instant use in the case of fire or other required exit path shall remain unobstructed at all times.No storage emergency where the building area served by the means of shall be kept in hallway. egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. \r-spm, GENERATED ON 8/13/28, 7:42 AN 2 OF 11 Additional Codes Stasis code Description Fail 1013.1-Where required. Exits and exit access doors shall be marked by an approved Location:NW corner-Sales floor exit sign readily visible from any direction of egress travel. Comments:Rotate exit sign to direct path of egress from view of The path of egress travel to exits and within exits shall be western most aisle. marked by readily visible exit signs to clearly indicate the direction of egress travel in cases where the exit or the path of egress travel is not immediately visible to the occupants. Intervening means of egress doors within exits shall be marked by exit signs.Exit sign placement shall be such that any point in an exit access corridor or exit passageway is within 100 feet(30 480 mm)or the listed viewing distance of the sign,whichever is less,from the nearest visible exit sign. Exceptions:1.Exit signs are not required in rooms or areas that require only one exit or exit access.2.Main exterior exit doors or gates that are obviously and clearly identifiable as exits need not have exit signs where approved by the fire code official.3.Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1,R-2 or R-3.4.Exit signs are not required in dayrooms,sleeping rooms or dormitories in occupancies in Group 1-3.5.In occupancies in Groups A-4 and A-5,exit signs are not required on the seating side of vomitories or openings into seating areas where exit signs are provided in the concourse that are readily apparent from the vomitories. Egress lighting is provided to identify each vomitory or opening within the seating area in an emergency. Fail 1013.1-Where required. Exits and exit access doors shall be marked by an approved Location:SE corner-Above desk chairs exit sign readily visible from any direction of egress travel. Comments:Rotate exit sign to point egress path of travel towards The path of egress travel to exits and within exits shall be rear exit. marked by readily visible exit signs to clearly indicate the direction of egress travel in cases where the exit or the path of egress travel is not immediately visible to the occupants. Intervening means of egress doors within exits shall be marked by exit signs.Exit sign placement shall be such that any point in an exit access corridor or exit passageway is within 100 feet(30 480 mm)or the listed viewing distance of the sign,whichever is less,from the nearest visible exit sign. Exceptions:1.Exit signs are not required in rooms or areas that require only one exit or exit access.2.Main exterior exit doors or gates that are obviously and clearly identifiable as exits need not have exit signs where approved by the fire code official.3.Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1,R-2 or R-3.4.Exit signs are not required in dayrooms,sleeping rooms or dormitories in occupancies in Group 1-3.5.In occupancies in Groups A-4 and A-5,exit signs are not required on the seating side of vomitories or openings into seating areas where exit signs are provided in the concourse that are readily apparent from the vomitories. Egress lighting is provided to identify each vomitory or opening within the seating area in an emergency. Fail 603.1.1-Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, Location:Break room wiring,devices and appliances shall be tested;and listed by Comments:Remove microwave and air fryer plugged to power strip, an approved agency and labeled;and installed,used and appliances including heat producing elements or motors shall plug maintained in accordance with NFPA 70 and all instructions directly to a permanent outlet.Also,power strips shall be properly included as part of such listing. mounted to avoid hanging by wires. GENERATED ON 8/13/28, 7:42 AM 3 OF 11 Fail 901.4.7.2-Marking on access doors. Access doors for automatic sprinkler system riser rooms and Location:Rear of building-Exterior door near sprinkler riser fire pump rooms shall be labeled with an approved sign,The Comments:Permanent approved signage shall be installed on lettering shall be in contrasting color to the background. exterior side of door indicating"SPRINKLER RISER"or like wording. Letters shall have a minimum height of 2 inches(51 mm)with Laminated paper will not be accepted. a minimum stroke of 318 inch(10 mm). Emergency Equipment Code Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Backup emergency lighting illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Provide documentation of testing all egress lighting including repairs completed of any deficiencies to maintain working properly.Document shall state address,date and signature of responsible person.Email document to inspector at brad.baldwin@waterloo-ia.org Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:All exit signage in Section 1013.6,3,The system shall be capable of powering Comments:Provide documentation of testing all exit signs including the required load for a duration of not less than 90 minutes. repairs completed of any deficiencies to maintain working properly. Document shall state address,date and signature of responsible person.Email document to inspector at brad.baldwin@waterloo- ia.org Fire Sprinkler System Status Code Description Fail 5.2.1.1.5-Missing escutcheons Ox Escutcheons and coverplates for recessed,flush,and Location:Back storage near drinking fountains concealed sprinklers shall be replaced if found missing Comments:Sprinkler escutcheon shall be installed tight to ceiling. during the inspection. GENERATED ON 8/13/26, 7:42 AM 4 OF 11 Fire Service Features ``alto, Code Description Fail 505.1-Address identification. New and existing buildings shall be provided with approved Comments:Current address numbers very difficult to see from the address identification.The address identification shall be street.Relocate address numbers compliant to code requirements or legible and placed in a position that is visible from the street alter current numbers to make more visible. or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 112 inch(12.7 mm).Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. Fail 507.5.5-Clear space around hydrants. A 3-foot(914 min)clear space shall be maintained around the Location:Rear of building circumference of fire hydrants,except as otherwise required Comments:Clear vegetation obstructing hydrants. or approved. Fail 509.2-Equipment access. Ox Approved access shall be provided and maintained for all fire Location:Back storage area protection system equipment to permit immediate safe Comments:Remove all storage within 3 feet of sprinkler riser operation and maintenance of such equipment.Storage,trash equipment,maintain proper clearances at all times.Suggest marking and other materials or objects shall not be placed or kept in floor where storage shall not be kept to avoid repeat violation. such a manner that would prevent such equipment from being readily accessible. r IFJ zh ,.` 0 Wee i Fri , , ' - _ -,a GENERATED ON 8/13/28, 7;42 AM 5 OF 11 Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:Near front exit protection system equipment to permit immediate safe Comments:Relocate stand-up signage obstructing view of alarm pull operation and maintenance of such equipment.Storage,trash station from all sides. and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. .w srt' bepd� %th p • „ • IR - fV v t a 3 f" GENERATED ON 8/13/28, 7:42 AM 6 OF 11 Electrical Safety Status Cone Description Fall 603.2.2-Unapproved conditionsOpen electrical terminations. 0 Open junction boxes and open-wiring splices shall be Location:Middle storage room prohibited.Approved covers shall be provided for all switch Comments:Provide knockout plug for opening in box. and electrical outlet boxes. , y u II 40 Fail 603.2.2-Unapproved conditionsOpen electrical terminations. OOpen junction boxes and open-wiring splices shall be Location:Break room-near extinguisher prohibited.Approved covers shall be provided for all switch Comments:Provide missing outlet cover and electrical outlet boxes. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. OOpen junction boxes and open-wiring splices shall be Location:Customer service prohibited.Approved covers shall be provided for all switch Comments:Repair loose outlets cover inside cabinet. and electrical outlet boxes. i 1 '4'. / il 4-1 il I I . v • r �, T GENERATED ON 8/13/28, 7:42 AM 7 OF 11 Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Cash room door with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide permanent approved signage on door indicating ROOM"or similar approved wording.The disconnecting "ELECTRIC ROOM"or similar wording,laminated paper will not be means for each service,feeder or branch circuit originating accepted. on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Middle storage room-near cash room with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide permanent approved signage on door indicating ROOM"or similar approved wording.The disconnecting "ELECTRIC ROOM"or similar wording,laminated paper will not be means for each service,feeder or branch circuit originating accepted. on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Managers office ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip below desk shall be properly mounted or to environmental or physical damage. supported to avoid hanging by wires. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Passport photos sign for permanent wiring and shall be listed and labeled in Comments:Extension cord shall be removed,may be replaced with accordance with UL 817.Extension cords and flexible properly supported power strip with manual reset for low wattage cordsshall not be affixed to structures,extended through electronics only. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. a. GENERATED ON 8/13/28, 7:42 AM 8 OF 11 Fire Resistant Construction Maintenance Status Cod, Description Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Back storage-Above drinking fountains materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tiles. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floorlceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Managers office materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tiles. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERATED ON S/13/26, 7:42 Aft 9 OF 11 Portable Fire Extingusihers code Description Fail 906.6-Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or Location:Back storage-near sprinkler riser obscured from view.In rooms or areas in which visual Comments:Repair or replace extinguisher signage falling off wall. obstruction cannot be completely avoided,means shall be provided to indicate the locations of extinguishers. \1 i , , �. GENERATED ON 8/13/28, 7:42 AM 10 OF 11 . 0 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $110.00 Invoice Number Check Number Transaction Number N/A N/A NIA GENERATED ON 8/13/26, 7:42 AN 11 OF 11