COMMERCIAL FIRE INSPECTION - 2110 KIMBALL AVE-08/13/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
25042 08/31/2026 10/05/2026 2027-00000088 $80.00
Less Prepayment $0.00
Total Due-* $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
aLkeal
Dcp.dAd &/41113134AV°/
Waterloo Fire Rescue
Inspection Report iit ttA41
425 E.3rd Street
041.11, Bambinos Love Bakery-2110 Kimball AVE,BLDG 2110 Kimball Ave,Waterloo IA
50701
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
08/13/2026 Annual Inspection(1Yr) 4 so tro 28777
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A NIA NIA
Other Inspectors
NIA
SUMMARY OF INSPECTION
0 29 0 11 0 40
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to:
Reinspection Date
BRAD BALDWIN
brad.baldwin@waterloo-ia.org,3192914319
09/14/2026
GENERAL NOTES
BRAD BALDWIN-08/13/2026 @ 11:25
•$80 annual inspection fee
BRAD BALDWIN-08/13/2026 @ 11:25
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224
BRAD BALDWIN-08/13/2026 @ 11:25
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Haley Sweet 2026 Date: BRAD BALDWIN 08113/2026
CHECKLISTS
GENERATED ON 8/13/26, 11:29 AM
1 OF
Additional Codes
Status Code Description
Fail 603.1-General.
Electrical equipment,wiring and systems required by this Location:Decorating area-Microwave
code or the International Building Code shall be installed, Comments:Remove microwave plugged to multi-plug adapter.
used and maintained in accordance with NFPA 70 and Appliances including heat producing elements or motors shall plug
Sections 603.2 through 603.10. directly to permanent outlet.
Fail 603.1-General.
Electrical equipment,wiring and systems required by this
code or the International Building Code shall be installed,
used and maintained in accordance with NFPA 70 and
Sections 603.2 through 603.10.
c.r,
Fail 610.1.2-Maintenance.
The lint trap,mechanical and heating components,and the Location:Clothes dryer
exhaust duct system of a clothes dryer shall be maintained in Comments:Dryer vent shall be cleaned from the appliance to the
accordance with the manufacturer's operating exterior of building.Provide document to inspector of completed
instructions to prevent the accumulation of lint or debris that annual cleaning.
prevents the exhaust of air and products of combustion.
2 OF 7
GENERATED ON 8/13/26, 11:29 AM
Electrical Safety
Status Code Description
Fail 603.6-Extension cords.
OExtension cords and flexible cordsshall not be a substitute Location:Front window"Open"sign
for permanent wiring and shall be listed and labeled in Comments:Remove extension cord.May replace with properly
accordance with UL 817.Extension cords and flexible supported power strip with manual reset switch for low wattage
cordsshall not be affixed to structures,extended through electronics only.
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Fail 603.6-Extension cords.
0 Extension cords and flexible cordsshall not be a substitute Location:Dough roller
for permanent wiring and shall be listed and labeled in Comments:Cord across walk path shall be protected by listed cord
accordance with UL 817.Extension cords and flexible protector to avoid possible damage to cord.
cordsshall not be affixed to structures,extended through
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Jaeuwtr.
J
Fail 603.6-Extension cords.
OExtension cords and flexible cordsshall not be a substitute Location:Chest freezer near walk-in cooler
for permanent wiring and shall be listed and labeled in Comments:Freezer shall plug directly to permanent outlet,remove
accordance with UL 817.Extension cords and flexible from extension cord.
cordsshall not be affixed to structures,extended through
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
GENERATED ON 8/13/26, 11:29 AM 3 OF
Fire Resistant Construction Maintenance
Sta[us Code Description
Fail 704.1-Maintaining protection.
Where required when the building was originally constructed, Location:Above ovens near back exit
materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile
following locations shall be maintained.The materials and
systems shall be securely attached to or bonded to the
adjacent construction,without openings visible through the
construction.1.Joints in or between fire-resistance-rated
walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall.4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall.5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall.6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall.7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly.Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed.Where the system design number is known,the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Fail 704.1-Maintaining protection.
Where required when the building was originally constructed, Location:Storage closet near laundry
materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile
following locations shall be maintained.The materials and
systems shall be securely attached to or bonded to the
adjacent construction,without openings visible through the
construction.1.Joints in or between fire-resistance-rated
walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall.4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall.5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall.6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall.7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly.Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed.Where the system design number is known,the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
GENERATED ON 8/13/26, 11:29 AM 4 OF 7
Portable Fire Extingusihers
Status Code Description
Fail 906.2-General requirements.
OPortable fire extinguishers shall be selected,installed and Location:All extinguishers
maintained in accordance with this section and NFPA 10. Comments:Provide required annual service to extinguishers,last
Exceptions:1.The distance of travel to reach an extinguisher recorded service in January 2024
shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-clay inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device,provided that all of the
following conditions are met:2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal.2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10.3.In Group 1-3,portable fire
extinguishers shall be permitted to be located at staff
locations.
Fail 906.2-General requirements.
OPortable fire extinguishers shall be selected,installed and Location:Near back exit door
maintained in accordance with this section and NFPA 10. Comments:Spare extinguisher sitting on floor(last serviced 2013)
Exceptions:1.The distance of travel to reach an extinguisher shall be serviced and mounted on bracket or removed from building
shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device,provided that all of the
following conditions are met:2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal.2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10.3.In Group 1-3,portable fire
extinguishers shall be permitted to be located at staff
locations.
GENERATED ON 8/13/26, 11:29 AM 5 OF 7
Fail 906.6-Unobstructed and unobscured.
Portable fire extinguishers shall not be obstructed or Location:Near clothes laundry
obscured from view.In rooms or areas in which visual Comments:Remove obstructions to clear access to extinguisher
obstruction cannot be completely avoided,means shall be
provided to indicate the locations of extinguishers.
4.
I., c-;i
GENERATED ON 8/13/26, 11:29 AM 6 OF 7