Loading...
HomeMy WebLinkAboutBARNES & NOBLE-1518 FLAMMANG DRIVE OF W 4 PF INVOICE DATE DUE DATE INVOICE# TOTAL DUE °Pe 08/31/2026 10/05/2026 2027-00000089 $100.00 so u rrar�.. / O • • 1 `1 1 11 1 • "--7.77 T 0 Customer#: 10914 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BARNES &NOBLE 715 Mulberry St 1518 FLAMMANG DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 1518 FLAMMANG DR-08/24/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10914 08/31/2026 10/05/2026 2027-00000089 $100.00 Less Prepayment $0.00 Total Due —+ $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue d + Inspection Report 425 E.3rd Street Barnes&Noble-1518 Flammang DR,BLDG 1518 Flammang Dr,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number V { 0812412026 Annual Inspection(1Yr) U A 45 00.° 1054 Lead Inspector Shift Station Unit BRAD BALDWIN N/A N/A NIA Other Inspectors NIA SUMMARY OF INSPECTION 041 012 @23 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 09125/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-08126/2026 @ 06:55 •$110 annual inspection fee BRAD BALDWIN-08/25/2026 @ 07:48 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-08/25/2026 @ 07:49 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-08125/2026 @ 07:49 Annual fire alarm inspection and report to be uploaded to Compliance Engine due on 10/24126 BRAD BALDWIN-08127/2026 @ 11:03 •Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date.Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature No signature Report completededpost ostinspection Michelle Cable 2026 Date: BRAD BALDWIN 08/27/2026 CHECKLISTS GENERATED ON 8/27/26, 11:05 AM 1 OF 8 Means of Egress Status Cod, Description Fail 1032.2-Reliability. C} Required exit accesses,exits and exit discharges shall be Location:Back storage-"Receiving Room" continuously maintained free from obstructions or Comments:Remove all storage&obstructions to clear path of impediments to full instant use in the case of fire or other egress to exit hallway.Clear path of egress shall be maintained at all emergency where the building area served by the means of times. egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. 14. • } L ` GENERATED ON 8/2T/26, 11:05 AM 2 OF 8 Additional Codes Status Code Description Fail 1010.2.4-Locks and latches. Locks and latches shall be permitted to prevent operation of Location:Main exit doors doors where any of the following exist:1.Places of detention Comments:Provide permanent signage on west door of double or restraint.2.In Group I-i,Condition 2 and Group 1-2 doors indicating THIS DOOR SHALL REMAIN UNLOCKED DURING occupancies where the clinical needs of persons receiving BUSINESS HOURS"or other approved wording on the interior side of care require containment or where persons receiving care the door, pose a security threat,provided that all clinical staff can readily unlock doors at all times,and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups B,F,M and S, and in places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3.3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.8.Other than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key- operated locking device.8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9,Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space, GENERATED ON 8/27/26, 11:05 AM 3 OF 8 Fail 1011.12,2-Roof access. Where a stairway is provided to a roof,access to the roof Location:Roof access ladder shall be provided through a penthouse complying with Comments:Remove storage from obstructing clear path of access to Section 1511.2 of the International Building Code.Exception: roof ladder. In buildings without an occupied roof,access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet(1.5 m2)in area and having a minimum dimension of 2 feet(610 mm). Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:8 Rooftop units-HVAC permit with the International Building Code,and any alterations, Comments:Contractor(Lennox National Acct Services)shall obtain additions,changes in use or changes in structures required inspection of work completed,permit obtained in March of 2024 to by this code,which are within the scope of the International replace 8 rooftop units. Building Code,shall be made in accordance therewith. General Housekeeping siaa;s Code Description Fail 315.3.2-Means of egress. Ox Combustible materials shall not be stored in exits or Location:Back hallway exit enclosures for stairways and ramps.Combustible materials in Comments:Remove all combustible material(ex:cardboard)from the means of egress during construction,demolition, exit hallway.Maintain combustible storage clear of exits at all times. remodeling or alterations shall comply with Section 3312.3. Fire Sprinkler System Description Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Coffee shop obstructions that will delay activation or obstruct the water Comments:Remove dustldebris from sprinkler heads above back distribution pattern and shall be in accordance with the wall sinks. applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fire Service Features S:e os C ode Description Fail 509.1-Identification. Fire protection equipment shall be identified in an approved Location:Managers office manner.Rooms containing controls for air-conditioning Comments:Permanent approved signage shall be installed on door systems,sprinkler risers and valves,or other fire detection, indicating"FIRE ALARM CONTROL PANEL"or"FACP".Signage shall suppression or control elements fire protection systems shall include white lettering with red background,laminated paper will not be identified for the use of the fire department.Approved be accepted. signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials,permanently installed and readily visible. GENERATED ON 8/27/28, 11:05 AM 4 OF 8 Electrical Safety Status Code Description Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Main electric panel room with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide permanent approved signage on door indicating ROOM"or similar approved wording.The disconnecting "ELECTRICAL ROOM"or other approved wording,laminated paper means for each service,feeder or branch circuit originating will not be accepted. on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Coffee shop for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to sandwich fridge. accordance with UL 817.Extension cords and flexible Extension cords shall not be used as permanent wiring.Relocate cordsshall not be affixed to structures,extended through appliance to plug directly to permanent outlet,or obtain licensed walls,ceilings or floors,or under doors or floor coverings, electrical contractor to add new outlet with permit and inspection. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fire Resistant Construction Maintenance Status Code Description Fail 705.2.4-Door operation. Ux Swinging fire doors shall close from the full-open position Location:Receiving area-Electric Room and latch automatically. Comments:Repair or replace fire rated door that failed to self shut and latch.Also,remove storage outside of door obstructing the ability for door to fully-open, GENERATED ON 8/27/28, 11:05 AM 5 OF 8 Portable Fire Extingusihers Scair.s Code Description, Fail 906.2-General requirements. Portable fire extinguishers shall be selected,Installed and Location:Sprinkler riser room maintained in accordance with this section and NFPA 10. Comments:Provide required annual service to extinguisher,last Exceptions:1.The distance of travel to reach an extinguisher tagged for service in 2023. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1,Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2,4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 8/27/28, 11:05 AM 6 OF 8 Fall 906.6-Unobstructed and unobscured. 0 Portable fire extinguishers shall not be obstructed or Location:Near Legos area obscured from view.In rooms or areas in which visual Comments:Provide signage(see attached)in approved location obstruction cannot be completely avoided,means shall be indicating extinguisher location or relocate extinguisher to an provided to indicate the locations of extinguishers. approved unobstructed location.Contact inspector for approved locations. FIRE 1 IT I N C U I S H E R GENERATED ON 8/27/28, 11:05 AM 7 OF 8 'o Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $110.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/27/26, 11:85 AM 8 OF 8