Loading...
HomeMy WebLinkAboutTHE BROWN BOTTLE-209 W 5TH STREET OF W q PF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 41, A. ( 08/31/2026 10/05/2026 2027-00000090 $80.00 • ' 11■ I I •11111 • ) T^�IFO 0s 1tf17‘3 ') Customer#: 3442 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable THE BROWN BOTTLE 715 Mulberry St 209 W 5TH ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 209 w 5th St-08/21/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE _ DUE DATE INVOICE# CHARGES 3442 08/31/2026 10/05/2026 2027-00000090 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue 1t4 Inspection Report 425 E.3rd Street Brown Bottle-209 W 5th ST,BLDG 209 W.5th St,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 08/21/2026 Annual Inspection(1Yr) !/A111� A-p 7 17996 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 058 L9 ® 14 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 09/14/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-08/21/2026 @ 08:13 •$80 annual inspection fee BRAD BALDWIN-08/21/2026 @ 08:14 •Commercial Fire Inspector—brad.baldwin@waterloo-ia.org—Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-08/21/2026 @ 08:14 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-08/21/2026 @ 08:14 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday—Friday,9:00 a.m.—4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-08/21/2026 @ 09:31 Sprinkler system required 5 year inspection and report to be uploaded to Compliance Engine is due on 10/14126. BRAD BALDWIN-08121/2026©09:46 Corrected during 8/20/26 inspection:(1)Removed storage from doorway leading out of Tuscany Room required exit path. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Mark Drenter Date: BRAD BALDWIN 08/21/2026 GENERATED ON 8/21/28, 10:14 AM 1 OF 5 CHECKLISTS Fire Sprinkler System Stetus Code Description Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Above Fruit Bowl art-near hostess stand obstructions that will delay activation or obstruct the water Comments:Remove debris from sprinkler head, distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:North dining area obstructions that will delay activation or obstruct the water Comments:Remove debris from several sprinkler heads noted distribution pattern and shall be in accordance with the throughout dining area. applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. GENERATED ON 8/21/28, 1e:14 AM 2 OF 5 Additional Codes Status Code Description Fail 5303.5.3-Securing compressed gas containers,cylinders Oand tanks. Location:Basement Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip secured to prevent falling caused by contact,vibration or over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: i.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Fail 610.1.2-Maintenance. OThe lint trap,mechanical and heating components,and the Location:Clothes dryer exhaust duct system of a clothes dryer shall be maintained in Comments:Provide documentation of cleaning of dryer vent from accordance with the manufacturer's operating appliance to the outside of the building with signature and date. instructions to prevent the accumulation of lint or debris that Email documentation to fire inspector. prevents the exhaust of air and products of combustion. Fail 807.3-Acceptance criteria and reports. T. Where required to exhibit improved fire performance, Location:Tuscany Room curtains,draperies,fabric hangings and other similar Comments:Provide documentation of flame spread test results by an combustible decorative materials suspended from walls or approved test agency of partition curtains.Unable to locate labeling ceilings shall be tested by an approved agency and meet the or tag on curtains during 8/20126 inspection. flame propagation performance criteria of Test Method 1 or Test Method 2,as appropriate,of NFPA 701 or exhibit a maximum rate of heat release of 100 kW when tested in accordance with NFPA 289,using the 20 kW ignition source. Reports of test results shall be prepared in accordance with the test method used and furnished to the fire code official upon request. GENERATED ON 8/21/26, 10:14 AM 3 OF 5 Electrical Safety Status Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. C) Open junction boxes and open-wiring splices shall be Location:Walk-in cooler prohibited.Approved covers shall be provided for all switch Comments:Provide moisture proof cover for light fixture and electrical outlet boxes. Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:North dining for permanent wiring and shall be listed and labeled in Comments:Remove extension cord to christmas lighting,flexible accordance with UL 817.Extension cords and flexible cords shall not extend above drop ceiling nor shall be used as cordsshall not be affixed to structures,extended through permanent wiring. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:NE dining area for permanent wiring and shall be listed and labeled in Comments:Remove extension cord extending above drop ceiling. accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Walk-in cooler for permanent wiring and shall be listed and labeled in Comments:Flexible wiring to door shall not pass through ceiling or accordance with UL 817.Extension cords and flexible walls of cooler.Licensed electrical contractor shall make code cordsshall not be affixed to structures,extended through appropriate corrections.Obtain copy of invoice from contractor and walls,ceilings or floors,or under doors or floor coverings, provide to inspector. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. • 414111./ 11110,.. mil. 120 VOLTS 1ri i0r . GENERATED ON 8/21/26, 10:14 AM 4 OF 5 E8 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Invoice Number Check Number Transaction Number N/A N/A N/A GENERATED ON 8/21/26, 10:14 AM 5 OF 5