Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
KELLY PROPERTY INVESTMENT LLC-3639 CANTERBURY COURT24078
0� W q r4° INVOICE DATE DUE DATE INVOICE# TOTAL DUE ," ,A 08/31/2026 10/05/2026 2027-00000091 $150.00 T-' ! 0 3 it(ON Customer#: 24078 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable KELLY PROPERTY INVESTMENT LLC 715 Mulberry St 2921 PENDLETON DR WATERLOO, IA 50703 CEDAR FALLS, IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-3639 cantebury ct-08/24/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 2 $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24078 08/31/2026 10/05/2026 2027-00000091 $150.00 Less Prepayment $0.00 Total Due -* $150.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street BLDG Canterbury Court Condo g 3639 anterbury Ct-3639 Canterbury CT, Waterloo IA 50702-5726 INSPECTION DETAILS Ctc7 Inspection Date Inspection Type Inspection Number 08/24/2026 Residential Common Areas Inspection REINSPECTION , 5 ) co 20158-R4 Lead Inspector Shift Station Unit NATE BEUSELING NIA N/A NIA Other Inspectors N/A SUMMARY OF INSPECTION 0 0 11 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date NATE BEUSELING nate.beuseling@waterloo-ia.org 09/25/2026 GENERAL NOTES NATE BEUSELING-06/30/2026©13:43 Reinspection scheduled for 6-30-2026 was at properties from 1245 to 110 with no representation present 100.00 fee NATE BEUSELING-06/30/2026 @ 13:43 $50 Re-inspection fee.rescheduled from 3/11 to 4/8.No show 418.Very little accomplished. NATE BEUSELING-06/30/2026 @ 13:43 Re-inspection date is as posted on the inspection report.The rental unit's responsible person/s shall contact prior to inspection date to set up time of re- inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150, and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections. NATE BEUSELING-0613012026 @ 13:43 Common area annual inspection completed at rental inspection so no charge for annual this time. NATE BEUSELING-06/3012026 @ 13:43 Inspection was scheduled for 5/18/26 after a no show on 4/8.An email was sent with the new date on 4/8 and a text was sent the morning of 5/18.No response and no show @ 915 or 115. NATE BEUSELING-06/30/2026 @ 13:43 Re-inspection fee$150 NATE BEUSELING-08/27/2026 @ 13:09 No show reinspection fee 150.00 SIGNATURES Contact signature Inspector signature GENERATED ON 8/27/28, 1:10 PM 1 OF 5 No signature Report completed post inspection Mike Kelly Date: ninrc CHECKLISTS OF GENEPATED ON 8/17/1P, 1:19 PM 2 J Reinspection Status Code Description Fail 1032.2- Reliability. 0 Required exit accesses, exits and exit discharges shall be Location: 1st floor corridor continuously maintained free from obstructions or Comments: remove chair, no storage in corridors. impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Fail 1032.4- Exit signs. Exit signs shall be installed and maintained in accordance Location: West entry with the building code that was in effect at the time of Comments: repair/replace exit/egress sign. Egress lights hanging by construction and the applicable provisions in Section 1104. wires. Decorations, furnishings, equipment or adjacent signage that impairs the visibility of exit signs, creates confusion or prevents identification of the exit shall not be allowed. Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1 Single or multiple-station smoke alarms shall be installed and Location: 1st floor corridor maintained in Groups R-2, R-3, R-4 and I-1 regardless of Comments: repairlreplace smoke detector occupant load at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1 0 Single or multiple-station smoke alarms shall be installed and Location: 2nd Floor East Top of stairs maintained in Groups R-2, R-3, R-4 and 1-1 regardless of Comments: repairlreplace smoke de#ector, occupant load at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire Location: Knox box front of building code official and provide the new key where a lock is changed Comments: Provide all keys for all doors. Call Fire Inspector JD 319- or rekeyed. The key to such lock shall be secured in the key 291-4460 to get keys locked in. box. Fail 603.2 -Abatement of unsafe conditions and electrical Ohazards. Location: 1st Floor East Entry Identified electrical hazards shall be abated. Identified Comments: replace missing light fixture cover hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. GENERATED ON 8/27/26, 1:10 PM 3 OF 5 • Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:1st floor west entry prohibited.Approved covers shall be provided for all switch Comments:replace broken outlet cover,repair loose electrical outlet. and electrical outlet boxes. Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:1st Floor East Fire Door and latch automatically. Comments:Adjust door,has gap at top and catches carpet on bottom and does not completely self-close and latch. Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:Top of stairs East 2nd and latch automatically. Comments:Fire door must completely self-close and latch. Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:2nd Floor West and latch automatically. Comments:Fire door must completely self-close and latch. Fail 99999-Inspection Outcome ODid the inspection pass or fail? GENERATED ON 8/27/28, 1:10 PM 4 OF 5 Eo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $150.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/27/28, 1:10 PM 5 OF 5