HomeMy WebLinkAboutCASH ADVANCE-323 FRANKLIN STREET 0� W q T fi INVOICE DATE DUE DATE INVOICE# TOTAL DUE
" � 08/31/2026 10/05/2026 2027-00000096 $100.00
O
„ Ir4 , O
T Ir 0
4S 7a17•�
Customer#: 10855 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
CASH ADVANCE 715 Mulberry St
2842 UNIVERSITY WATERLOO, IA 50703
WATERLOO,IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION -323 FRANKLIN ST-08/31/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
REINSPECTION 1 $100.00
CUSTOMER#" BILLING DATE DUE DATE INVOICE# CHARGES
10855 08/31/2026 10/05/2026 2027-00000096 $100.00
Less Prepayment $0.00
Total Due —> $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report 425 E.3rd Street
Hometown Cash Advance-323 Franklin ST,BLDG 323 Franklin St,Waterloo IA
50703
INSPECTION DETAILS
Inspection Date Inspection Type !!l��1 Inspection Number
08131/2026 Annual Inspection(1Yr) REANSPECTION) jc8_, , 4 I no,— 532-R2
Lead Inspector Shin l/ Station Unit
BRAD BALDWIN N/A NIA N/A
Other Inspectors
NIA
SUMMARY OF INSPECTION
00 05
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN
09130/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-08/31/2026 @ 12:33
S100 re-inspection fee for failure to complete corrections on 8/31126 scheduled inspection.Complete corrections to avoid fees at following inspections.
BRAD BALDWIN-0 713 0/20 2 6 @ 14:59
•S80 annual inspection fee
BRAD BALDWIN-07/30/2026 @ 14:59
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319 05)-Cell:319-230-1224
BRAD BALDWIN-0 713 0/2 026 @ 14:59
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m."'"•Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at S100,then$150,and$200 for all subsequent re-inspections.
BRAD BALDWIN-07130/2026 @ 14:59
Withholding re-inspection fee on 7/30/26.Complete corrections to avoid fees at following inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completedetl post inspection
nspection
Mike Tiggelar-2026 Date: BRAD BALDWIN 08/31/2026
CHECKLISTS
GENERATED ON 8/31/20, 12:35 PM 4
Reinspection
Status Code Description
Fail 1010.2.4-Locks and latches.
OLocks and latches shall be permitted to prevent operation of Location:Back exit
doors where any of the following exist:1.Places of detention Comments:Not more than a single motion allowed to unlatch and
or restraint.2.In Group I-1,Condition 2 and Group 1-2 unlock door to exit.Options:(1)Remove all hardware not in
occupancies where the clinical needs of persons receiving compliance to code.(2)Second exit not required per occupancy and
care require containment or where persons receiving care approved by City Permit Writer,Jennifer Sparks to remove all exit
pose a security threat,provided that all clinical staff can signage directing towards back(north)exit including capping
readily unlock doors at all times,and all such locks are keyed electrical wires and containing in box with cover.Removing exit
to keys carried by all clinical staff at all times or all clinical signage allows all(north)door hardware to remain as is currently.
staff have the codes or other means necessary to operate the
locks at all times.2.3.In buildings in occupancy Group A Additional comments:No progress on 8131126
having an occupant load of 300 or less,Groups B,F,M and S,
and in places of religious worship,the main door or doors are
permitted to be equipped with key-operated locking devices
from the egress side provided:2.1.3.1.The locking device is
readily distinguishable as locked.2.2.3.2.A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch
(25 mm)high on a contrasting background.2.3.3.3.The use
of the key-operated locking device is revocable by the fire
code official for due cause.3.4.Where egress doors are used
in pairs,approved automatic flush bolts shall be permitted to
be used,provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface-mounted
hardware.4.5.Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch,dead
bolt or security chain,provided such devices are openable
from the inside without the use of a key or tool.5.6.Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures.6.7.Doors serving roofs not intended to be
occupied shall be permitted to be locked,preventing entry to
the building from the roof.8.Other than egress courts,where
occupants must egress from an exterior space through the
building for means of egress,exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following:8.1.The maximum occupant load shall be posted
where required by Section 1004.9.Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways.8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side.8.3.The egress door locking
device is readily distinguishable as locked and shall be a key-
operated locking device.8.4.A clear window or glazed door
opening,not less than 5 square feet(0.46 m2)in area,shall
be provided at each exit access door to determine if there are
occupants using the outdoor area.8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating:"THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on
the sign shall be not less than 1 inch(25.4 mm)high on a
contrasting background.8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004.9.Locking devices are
permitted on doors to balconies,decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet(23.23
m2)or less,serving a private office space.
2 OF 4
GENERATED ON 8/31/26, 12:35 PM
Fall 1203.2.6 - Exit signs.
OEmergency power shall be provided for exit signs as required Location: Front exit
in Section 1013.6.3. The system shall be capable of powering Comments: Repair or replace exit sign and egress lights combo that
the required load for a duration of not less than 90 minutes. failed to illuminate during test
Additional comments: No progress on 8/31/26
Fail 1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required Location: Back exit
in Section 1013.6.3. The system shall be capable of powering Comments: Options: (1) Repair or replace exit sign that failed to
the required load for a duration of not less than 90 minutes. illuminate during test. (2) Second exit not required per occupancy
and approved by City Permit Writer, Jennifer Sparks to remove all exit
signage directing towards back (north) exit including capping
electrical wires and containing in box with cover.
Additional comments: No progress on 8/31/26
Fail 603.4.1 - Labeling.
ODoors into electrical control panel rooms shall be marked Location: Electric panel
with a plainly visible and legible sign stating "ELECTRICAL Comments: Provide approved permanent signage on door to panel
ROOM" or similar approved wording. The disconnecting closet indicating location of panel. Laminated paper will not be
means for each service, feeder or branch circuit originating accepted.
on a switchboard or panelboard shall be legibly and durably
marked to indicate its purpose unless such purpose is clearly Additional comments: No progress on 8/31126
evident. Where buildings or structures are supplied by more
than one power source, markings shall be provided at each
service equipment location and at all interconnected electric
power production sources identifying all electric power
sources at the premises in accordance with NFPA 70.
Fail 906.2 - General requirements.
Ox Portable fire extinguishers shall be selected, installed and Location: Extinguisher
maintained in accordance with this section and NFPA 10. Comments: Provide annual service to extinguisher, currently no tag
Exceptions: 1.The distance of travel to reach an extinguisher with date.
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required Additional comments: No progress on 8/31/26
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group 1-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
GENERATED ON S/31/26, 12:35 PM 3 OF 4
Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $100.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
4OF 4
GENERATED ON 8/31/28, 12:35 PM