Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
IOWA LIQUIDATION DEALS - 101 FLETCHER AVENUE23669
OF WA�. INVOICE DATE DUE DATE INVOICE# TOTAL DUE 08/31/2026 10/05/2026 2027-00000097 $80.00 u aia•�.• ` /A O • • II II II III • T T O Customer#: 23669 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable IOWA LIQUIDATION DEALS 715 Mulberry St 2840 UNIVERSITY AVE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 101 FLETCHER AVE-08/24/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23669 08/31/2026 10/05/2026 2027-00000097 $80.00 Less Prepayment $0.00 Total Due —* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue , Inspection Report 425 E.3rd Street 48 )' Iowa Liquidation Deals-101 Fletcher AVE,BLDG 101 Fletcher Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 08/24/2026 Biennial Inspection(2yrs) CZ' 80 786 Lead Inspector Station Unit JEREMIAH VANDYKE NIA NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION 03 012 G60 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date JEREMIAH VANDYKE 09/23/2026 jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE-08/24/2026 @ 15:51 PERMIT INFO:•Any construction,electrical,plumbing,life safety,and HVAC requires proper permit and inspections.•All electrical work and repair must be completed by a licensed electrical contractor with permits and inspections. JEREMIAH VANDYKE-08/24/2026©15:51 Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-08/24/2026 @ 15:51 Lt.J.D.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-1615 JEREMIAH VANDYKE-08/2412026 @ 15:52 Inspection Fee=$80.00(To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Nicole Floss Date: JEREMIAH VANDYKE 08124/2026 CHECKLISTS GENERATED ON 8/24/26, 4:24 PM 1 OF S Means of Egress Status Code Description Fall 1010.1.3-Door opening force Forces to unlatch and open doors. Location:Old service department door on south side. The force for pushing or pulling open Interior swinging Comments:Door needs to be adjusted to open properly. egress doors,other than fire doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(87 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Fail 1010.2.5-Bolt locks. Manually operated flush bolts or surface bolts are not Location:3 doors with 2 action locks.Both exits doors in the storage permitted.Exceptions:1.On doors not required for egress in area.Exit door in hallway old service department door. individual dwelling units or sleeping units.2.Where a pair of Comments:Discussed keeping the dead bolt only and removing doors serves a storage or equipment room,manually handles.Or keeping handles with lock and removing dead bolt. operated edge-or surface-mounted bolts are permitted on the inactive leaf.3.Where a pair of doors serves an occupant load of less than 50 persons in a Group B,For S occupancy, manually operated edge-or surface-mounted bolts are permitted on the inactive leaf.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware. 4.Where a pair of doors serves a Group B,For S occupancy, manually operated edge-or surface-mounted bolts are permitted on the inactive leaf provided that such inactive leaf is not needed to meet egress capacity requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware.5.Where a pair of doors serves patient care rooms in Group 1-2 occupancies,self-latching edge-or surface- mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress capacity requirements and the inactive leaf shall not contain doorknobs,panic bars or similar operating hardware. Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Hallway area is a marked exit. continuously maintained free from obstructions or Comments:No storage allowed in marked exit path. impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. GENERATED ON 0/24/26, 4:24 Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be Location: East storage area exit door. continuously maintained free from obstructions or Comments: Need to remove sheetrock and keep exit path clear. impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Fail 1032.3 -Obstructions. 0 A means of egress shall be free from obstructions that would Location: Steps leading to 2nd floor. prevent its use, including the accumulation of snow and ice. Comments: Need to clear steps for access to and from 2nd floor. Emergency Equipment Status Code Description Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress Location: Entire building. illumination in accordance with Sections 1008.3 and 1104.5.1. Comments: All Egress lights need to be repaired or replaced. Fail 1203.2.6 - Exit signs. Ox Emergency power shall be provided for exit signs as required Location: Entire buiding. in Section 1013.6.3. The system shall be capable of powering Comments: Multiple exit/egress lighting needs to repaired or the required load for a duration of not less than 90 minutes. replaced throughout building. Electrical Safety Status Code Description Fail 603.2 - Abatement of unsafe conditions and electrical 0 hazards. Location: Outside near main front door, Identified electrical hazards shall be abated. Identified Comments: Yellow electrical wiring is open. Needs to remove black hazardous electrical conditions in permanent wiring shall be electrical tape, be capped correctly, and wiring either removed or brought to the attention of the responsible code official. capped closed. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Location: Old Service desk in showroom on west wall under the desk Identified electrical hazards shall be abated. Identified area. hazardous electrical conditions in permanent wiring shall be Comments: Need to remove the make shift electrical boxes, wiring, brought to the attention of the responsible code official. and conduit or get licensed electrician to install correctly. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. XU Open junction boxes and open-wiring splices shall be Location: 2 open boxes on wall on storage side that leads from prohibited. Approved covers shall be provided for all switch showroom to storage. and electrical outlet boxes. Comments: Plate open electrical boxes X2. Fire Resistant Construction Maintenance Status Code Description Fail 705.2.4- Door operation. QSwinging fire doors shall close from the full-open position Location: 2 marked fire doors need to be adjusted and close properly. and latch automatically. Comments: 2 marked fire doors need to be adjusted and close properly. GENERATED ON 8/24/28, 4:24 PM 3 OF 5 Portable Fire Extingusihers Status Code Description Fail 906.1-Where required. Portable fire extinguishers shall be installed in all of the Location:5 fire extinguishers need to serviced and mounted.4 on 1st following locations:1.In new and existing Group A,B,E,F,H, floor and 1 on 2nd floor. I,M,R-1,R-2,R-4 and S occupancies.Exceptions:i,in Group Comments:5 fire extinguishers need to serviced and mounted.4 on R-2 occupancies,portable fire extinguishers shall be required 1st floor and 1 on 2nd floor. only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use.3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4. Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1;1-2,Condition 1;and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed.4.0n each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. GENERATED ON 8/24/26, 4:24 PM 4 OF 5 Ea Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/24/28, 4:24 RN 5 OF 5