Loading...
HomeMy WebLinkAboutLOWEST HOME IMPROVEMENT-400 E. TOWER PARK DRIVE OF W 4 . INVOICE DATE DUE DATE INVOICE# TOTAL DUE ...A.A411111111V( is 08/31/2026 10/05/2026 2027-00000099 $100.00 • •ut ■ 111111 III II • > T -T O Customer#: 12176 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LOWES HOME IMPROVEMENT 715 Mulberry St 400 E TOWER PARK WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 400 E TOWER PARK DR- FOR BILLING INQUIRY: (319)291-4323 08/31/26 Description Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12176 08/31/2026 10/05/2026 2027-00000099 $100.00 Less Prepayment $0.00 Total Due --> $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 4,* Waterloo Fire Rescue t W Inspection Report 425 E.3rd Street •""* Lowes-400 E tower park DR,BLDG 400 E Tower Park Dr,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 08/31/2026 Annual Inspection(1Yr) J REINSPECTION) + , 1 J(1�,p.'' 17421-R2 Lead Inspector Shift Station vv Unit BRAD BALDWIN NIA N/A N/A Other Inspectors N/A SUMMARY OF INSPECTION 00 03 013 Passed codes Resolved violations Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN brad.baldwin@waterloo-ia.org,3192914319 09/30/2026 GENERAL NOTES BRAD BALDWIN-08/31/2026 @ 15:48 $100 re-inspection fee for failure to complete corrections on scheduled 8/31/26 inspection.Complete corrections to avoid fees at following inspections. BRAD BALDWIN-08/03/2026 @ 08:24 •$610 annual inspection fee BRAD BALDWIN-08103/2026 @ 08:24 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-08103/2026 @ 08:24 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-08/03/2026 @ 08:24 Withholding re-inspection fee on 7/31/26 due to progress made.Complete corrections to avoid fees at following inspections. SIGNATURES Contact signature Inspector signature No signature Report completededpost stinspection Scott June Date: BRAD BALDWIN 08131/2026 CHECKLISTS GENERATED ON 8/31/2G, 3:49 PM 1 OF 6 Reinspection Status Code Description Fall 1010.1.3-Door opening force Forces to unlatch and open doors. Location:Lawn&garden-Gate 495 The force for pushing or pulling open Interior swinging Comments:Lett exit door shall be repaired or replaced to allow door egress doors,other than fire doors,shall not exceed 5 to open with less than 15lbs of force.Door failed to open easily today. pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:All of building illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Provide documentation of testing all emergency egress lighting in the building including repairs made to maintain working properly,documentation shall include address,signature and date of responsible person. Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:All of building in Section 1013.6.3.The system shall be capable of powering Comments:Provide documentation of testing all exit signs in the the required load for a duration of not less than 90 minutes. building including repairs made to maintain working properly, documentation shall include address,signature and date of responsible person. Fail 5.2.1-Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed Location:Sprinkler system contractor Comments:Provide annual inspection and contractors report including all deficiencies corrected to be uploaded to Compliance Engine.Currently 48 days past due for inspection. Additional comments:Deficiencies still remains on Compliance Engine ®m Fail 5.2.1.1.5-Missing escutcheons Escutcheons and coverplates for recessed,flush,and Location:Break room concealed sprinklers shall be replaced if found missing Comments:Replace missing escutcheon near exit door. during the inspection. Additional comments:No progress on 8131126 OF e GENERATED ON 8/31/3e, 3:49 PP! Fall 507.5.2 - Inspection, testing and maintenance. 0 Fire hydrant systems shall be subject to periodic tests as Location: Private fire hydrants required by the fire code official. Fire hydrant systems shall Comments: Provide annual inspection and contractors report be maintained in an operative condition at all times and shall including all deficiencies corrected to be uploaded to Compliance be repaired where defective. Additions, repairs, alterations Engine. Currently 48 days past due for inspection. and servicing shall comply with approved standards. Records of tests and required maintenance shall be maintained. Additional comments: Deficiency still remains on Compliance Engine .-..emu- •LYOttYt�+w. ws -MI Fail 509.1 - Identification. 0 Fire protection equipment shall be identified in an approved Location: Aisle 53, bay 19 - near ladders manner. Rooms containing controls for air-conditioning Comments: "HOSE CONNECTION" signage hidden up in ceiling systems, sprinkler risers and valves, or other fire detection, trusses. Signage shall be in place indicating location of sprinkler suppression or control elements fire protection systems shall hose connection at all times. be identified for the use of the fire department. Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Fail 509.1 - Identification. Fire protection equipment shall be identified in an approved Location: Aisle 39, bay 17 - near tile tools manner. Rooms containing controls for air-conditioning Comments: "HOSE CONNECTION" signage hidden up in ceiling systems, sprinkler risers and valves, or other fire detection, trusses. Signage shall be in place indicating location of sprinkler suppression or control elements fire protection systems shall hose connection at all times. be identified for the use of the fire department. Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Fail 509.1 - Identification. OX Fire protection equipment shall be identified in an approved Location: Aisle 45, bay 20 - near vanitys manner. Rooms containing controls for air-conditioning Comments: "HOSE CONNECTION" signage hidden u pin ceiling systems, sprinkler risers and valves, or other fire detection, trusses. Signage shall be in place indicating location of sprinkler suppression or control elements fire protection systems shall hose connection at all times. be identified for the use of the fire department. Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Fail 603.1 - General. 0 Electrical equipment, wiring and systems required by this Location: Break room code or the International Building Code shall be installed, Comments: Remove toaster plugged to power strip. Appliances with used and maintained in accordance with NFPA 70 and motors or heat producing elements shall plug directly to a permanent Sections 603.2 through 603.10. outlet Additional comments: New outlet installed requires licensed electrical contractor to obtain permit and inspection. GENERATED ON 8/31/20, 3:49 PM 3 OF 6 Fail 6107.3-Clearance to combustibles. Weeds,grass,brush,trash and other combustible materials Location:South exterior of building shall be kept not less than 10 feet(3048 mm)from LP-gas Comments:Remove all combustible material(pallets)within 10ft of tanks or containers, propane cabinet. i 1 �iii.r 1 r• i UMW f��� A -- ;, • N Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Seasonal area obstructions that will delay activation or obstruct the water Comments:Gazebo shall be removed due to obstruction of sprinkler distribution pattern and shall be in accordance with the head coverage or sprinkler head added below ceiling. applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. ' . 116-3 q8‘.* ii al ri 3 r t' h1 -1 �. l r 1 Oil - _ 4 OF 6 GENERATED ON 8/31/26, 2:46 PM Fail Chapter 14-Inspection,testing,and maintenance Fire alarm system tested at least annually by licensed Location:Fire alarm contractor Comments:Provide annual inspection and contractors report including all deficiencies corrected to be uploaded to Compliance Engine.Currently due for inspection on 7115126,"battery trouble" alarm noted during 6129126 inspection. Additional comments:No report in Compliance Engine as of 8/31126 t SO • GENERATED ON 8/31/26, 3:49 PM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA 60F 6 GENERATED ON 8/31/28, 3:49 PM