Loading...
HomeMy WebLinkAboutR SMOKES PLUS - 3821 UNIVERSITY AVENUE OF W A 7.4" INVOICE DATE DUE DATE INVOICE# TOTAL DUE ,,� 08/31/2026 10/05/2026 2027-00000104 $100.00 /%o U. ' 1 II�' •1•,1 • 7tl11N Customer#: 24657 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable R SMOKES PLUS 715 Mulberry St 3628 KIMBALL AVE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 3821 UNIVERSITY AVE- FOR BILLING INQUIRY: (319)291-4323 08/24/26 Description Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE _ INVOICE# CHARGES 24657 08/31/2026 10/05/2026 2027-00000104 $100.00 Less Prepayment $0.00 Total Due—* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 4,,., Waterloo Fire Rescue Inspection Report 425 E.3rd Street R Smokes Plus-3821 University AVE,BLDG 3821 University Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type ( Inspection Number 08/24/2026 Annual Inspection(lYr) REINSPECTION &5 -7- \co. 22882-R3 Lead Inspector Shift Station Unit BRAD BALDWIN N/A N/A N/A Other Inspectors N/A SUMMARY OF INSPECTION ' 0 1 8 Passed codes Resolved violations Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN brad.baldwin@waterloo-ia.org,3192914319 09/21/2026 GENERAL NOTES BRAD BALDWIN-08124/2026 @ 11:24 $100 re-inspection fee for failure to complete corrections on scheduled 8/24/26 inspection.Complete corrections to avoid fees at following inspections. Discussed remaining corrections with on-site staff today during 8/24/26 inspection. BRAD BALDWIN-07/27/2026 @ 08:12 •$80 annual inspection fee BRAD BALDWIN-07/27/2026 @ 08:12 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07/27/2026 @ 08:12 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-07127/2026 @ 08:12 Please note:Initial inspection(#22882)scheduled re-inspection date of 7115/26 will not be reset to 7/22/26 due to additional violations added per walk through with City Electrical Inspector. BRAD BALDWIN-07/27/2026 @ 08:12 Withholding re-inspection fee due to some progress on 7/22/26 inspection.Complete corrections to avoid fees at following inspections. SIGNATURES Contact signature Inspector signature No signature Report completededpost stinspection GENERATED ON 8/24/26, 11:25 AM 1 OF 6 Nabii•2026 Date: BRAD BALDWIN 0812412026 CHECKLISTS 2OF 6 GENERATED ON 8/24/28, 11:25 AM Reinspection Status Code Description Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Cigar room with the International Building Code,and any alterations, Comments:Building and electrical permits shall be obtained for additions,changes in use or changes in structures required by this code,which are within the scope of the International "Cigar Room"constructed without permits. Building Code,shall be made in accordance therewith. Additional comments:No permit in system on 8124/26 • =r 1 Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Electrical code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Comments:All electrical MC cable and wiring shall be installed in Sections 603.2 through actor 603.10. electrical code compliance,multiple issues noted by City Electrical Inspector during 6/24/26 walk-thru.Display case lighting shall be listed and used per its listing,provide documentation of case lighting to inspector.Licensed electrical contractor shall make all necessary repairs,obtain invoice to provide to inspector. Additional comments:No repairs made as of 8/24/26 GENERATED ON 8/24/28, 11:25 AM 3 OF 6 Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Cigar cutters display case Identified electrical hazards shall be abated.Identified Comments:Licensed electrical contractor shall make corrections to hazardous electrical conditions in permanent wiring shall be wiring unprotected entering box.Obtain invoice from electrician to brought to the attention of the responsible code official. show inspector Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that Additional comments:No progress made 8124126 constitute an electrical shock or fire hazard shall be abated not be used. N •�1 Fail 603.2-Abatement of unsafe conditions and electrical Location:Behind register counter hazards. Identified electrical hazards shall be abated.Identified Comments:Power strip cord shall be properly protected across hazardous electrical conditions in permanent wiring shall be walkway to avoid damage to cord hazard. brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment Additional comments:No progress,cord has become damaged and that is modified or damaged and constitutes Conditions that shall be replaced constitute an electrical shock or fire hazard shall be abated not be used. ler Ea aoFs GENERATED ON 8/24/28, 11:25 AM Fail 603.4.1-Labeling, 0 Doors into electrical control panel rooms shall be marked Location:Mechanical room with a plainly visible and legible sign stating"ELECTRICAL Comments:Ap proved permanent"Electric room"signage shall ROOM"or similar approved wording.The disconnecting installed on door,laminated paper will not be accepted. means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably Additional comments:no progress marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.5.3-Installation. ORelocatable power tap cords shall not extend through walls, Location:Mechanical room storage ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip hanging over green storage tote shall be to environmental or physical damage. mounted to avoid supported pported by wires. Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Cigar room for permanent wiring and shall be listed and labeled in Comments:Extension cord shall be removed.Also,cords shall not accordance with UL 817.Extension cords and flexible pass through doorways to avoid hazard of damaging cord. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, Additional comments:No progress made nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. • \ am. I Fail 603.6-Extension cords. Ox Extension cords and flexible cordsshall not be a substitute Location:TV above register counter for permanent wiring and shall be listed and labeled in Comments:Remove TV plugged to extension cord,would approve to accordance with UL 817.Extension cords and flexible replace with properly mounted power strip with manual reset for low cordsshall not be affixed to structures,extended through wattage usage only. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or Additional comments:No progress made physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 8/24/28, 11:25 AM 5 OF 6 '® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/24/28, 11:25 AN 6 OF 6