COMMERCIAL FIRE INSPECTION - 1517 FLAMMANG DR-08/28/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 1 $40.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE _ DUE DATE INVOICE# CHARGES
20689 08/31/2026 10/05/2026 2027-00000105 $50.00
Less Prepayment $0.00
Total Due--> $50.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
•
Waterloo Fire Rescue
* Inspection Report
425 E.3rd Street
Scratch Cupcakery•1517 Flammang DR,BLDG 1517 Flammang Dr,Waterloo IA
50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
08/28/2026 Annual Inspection(1Yr) ea0(CerA 10059
Lead Inspector Shift Station ���.../// Unit
BRAD BALDWIN NIA N/A NIA
Other Inspectors
N/A
SUMMARY OF INSPECTION
033 a4 ® 37
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN
09130/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-08/31/2026 @ 08:05
•$50 annual inspection fee
BRAD BALDWIN-08/31/2026 @ 08:05
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224
BRAD BALDWIN-08/31/2026 @ 08:05
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
BRAD BALDWIN-08131/2026 @ 08:06
Fire extinguishers due for required annual service in September 2026.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Abby McCurdy 2026 Date: BRAD BALDWIN 08/31/2026
CHECKLISTS
GENERATED ON t/91/2 , t:24 AM
1 OF 4
Additional Codes
Description
5',,is
Fail 1010.2.1-Unlatching.
The unlatching of any door or leaf for Location:Back exit door
egress shall require not require more than one operation Comments:Required exit doors shall not require more than a single
motion in a single linear or rotational direction to release all (1)motion to unlock and unlatch door,currently 2 motions exist with
latching and all locking devices.Exceptions:1.Places of lever handle and deadbolt lock.Door hardware shall be corrected to
detention or restraint.2.Where manually operated bolt locks comply with code.
are permitted by Section 1010,2.5.3.Doors with automatic
flush bolts as permitted by Section 1010.2.4,Item 3 4.4.Doors
from individual dwelling units and sleeping units of Group R
occupancies as permitted by Section 1010.2.4,Item 4 5.
Emergency Equipment
Description
Fail 1203.2.15-Means of egress illumination.
Emergency power shall be provided for means of egress Location:Front of house
illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Egress light very dull when tested,light shall be repaired
or replaced.
2 OF 4
GENERATED ON B/31/28, 8:24 AM
Electrical Safety
Code Description
Fail 603.4-Working space and clearancesclearance.
A working space of not Working space around electrical Location:Electric panel near back door
equipment shall be provided in accordance with Section
Comments:Storage shall be maintained 36 inches from electric panel
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or
less,and Section 110.33 of NFPA 70 for electrical equipment and clear path of access to panel at all times.
rated over 1,000 volts.The minimum required working space
shall be not less than 30 inches(762 min)in width,36 inches
(914 mm)in depth and 78 inches(1981 mm)in height shall be
providedin front of electrical service equipment,Where the
electrical service equipment is wider than 30 inches(762
mm),the minimum working space shall be not less than the
width of the equipment.Storage of materials shall not be
located within the designated working space.Exceptions:1.
Where other dimensions are required or allowed by NFPA 70.
2.Access openings into attics or under-floor areas that
provide a minimum clear opening of 22 inches(559 mm)by 30
inches(762 mm).
1
F iq
Ile
)' . / ,.. '\
.fir
f
•
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Cookie dough freezer
for permanent wiring and shall be listed and labeled in
accordance with UL 817.Extension cords and flexible Comments:Freezer shall be removed from plugged to extension
cord.Extension cords shall not be used as permanent wiring.If
cordsshall not be affixed to structures,extended through
adding a new outlet,licensed electrical contractor shall obtain permit
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or and inspection.
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.