Loading...
HomeMy WebLinkAboutSMOKE O'S VAPOR - 1509 FLAMMANG DRIVE OF W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 08/31/2026 10/05/2026 2027-00000106 $50.00 r o > o 4.4S 7d17`� Customer#: 24069 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SMOKE O'S VAPOR 715 Mulberry St 1509 FLAMMANG DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 1509 FLAMMANG DR-08/26/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 1 $40.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24069 08/31/2026 10/05/2026 2027-00000106 $50.00 Less Prepayment $0.00 Total Due —4 $50.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue 1.0114. Inspection Report 425 E.3rd Street Smoke O's Vapor•1509 Flammang DR,BLDG 1509 Flammang Dr,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 08/26/2026 Annual Inspection(1Yr) , go tQci r 10525 Lead Inspector Shift Station Unit BRAD BALDWIN NIA N/A NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 31 0 11 ® 33 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 09/25/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0812712026 @ 07:44 $50 annual inspection fee BRAD BALDWIN-08127/2026 @ 07:44 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-0812712026 @ 07:44 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature 1 Report completed post inspection Maggie Lies staff 2026 Date: BRAD BALDWIN 08127/2026 CHECKLISTS GENERATED ON 8/27/28, 7:48 AM 1 OF 9 Means of Egress States Code Description Fail 1010.1.3-Door opening force Forces to unlatch and open doors. Location:Back exit door The force for pushing or pulling open interior swinging Comments:Repair or replace exit door that failed to open with less egress doors,other than fire doors,shall not exceed 5 than 15Ibs of force.Replacing door requires commercial building pounds(22 N).These forces do not apply to the force permit and inspection. required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Back exit continuously maintained free from obstructions or Comments:Relocate storage(Boxes below extinguisher)obstructing impediments to full instant use in the case of fire or other clear path to exit.Clear path of egress to exit shall be maintained at emergency where the building area served by the means of all times. egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. : .� If r� �� 11110$', a .' 4 M t:.,,,itr41GENERATED ON 8/27/28, 7:48 AM 2 OF 9 Additional Codes Status Code Description Fail 102.3-Change of use or occupancy. A change of occupancy shall not be made unless the use or Location:Security Camera room occupancy is made to comply with the requirements of this Comments:Remove cot from building immediately.Sleeping is code and the International Existing Building Code. strictly prohibited in commercial space. Exception:Where approved by the fire code official,a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code,provided that the new or proposed use or occupancy is less hazardous,based on life and fire risk,than the existing use or occupancy. U., 4 w<. GENERATED ON 8/27/28, 7:48 AM 3 OF 9 Emergency Equipment St,at,is Code Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Back exit illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace emergency egress lights that failed to illuminate during test and one light bulb hanging by wires. Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Back exit in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign that failed to illuminate during the required load for a duration of not less than 90 minutes. test GENERATED ON 8/27/28, 7:48 AM 4 OF g Electrical Safety S,mus Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Near Hemp Papers prohibited.Approved covers shall be provided for all switch Comments:Provide missing outlet cover and electrical outlet boxes. 11 1BF�''. o Ma''R • GENERATED ON 8/27/28, 7:48 AM 5 OF 9 Fail 603.4-Working space and ciearancesclearance. A working space of not Working space around electrical Location:Back stock area equipment shall be provided in accordance with Section Comments:Remove storage within 36 inches of panel.Maintain 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or proper clearances and clear path of access at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). a r, ;:f I . i Ai e' t , _ fi ,, 1::-4,. 411—..--..— GENERATED ON 8/27/28, 7:48 AM 6 OF 9 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Behind cigar cabinet. for permanent wiring and shall be listed and labeled in Comments:Remove all extension cords behind cabinets.Extension accordance with UL 817.Extension cords and flexible cords shall not be used as permanent wiring. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. , l a . :\ Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Front wall corner behind display counter for permanent wiring and shall be listed and labeled in Comments:Extension cord extending above drop ceiling shall be accordance with UL 817.Extension cords and flexible removed.Extension cords shall not be used as permanent wiring and cordsshall not be affixed to structures,extended through flexible supply cords shall not pass through concealed spaces. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 6/27/26, 7:46 AM 7 OF 9 Fire Resistant Construction Maintenance 5[a:.is Code Description Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Security camera room materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tiles. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floorlceiling assemblies and roof or rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer&#039;s installation instructions. Portable Fire Extingusihers Sig ua COO Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Extinguishers(2) maintained in accordance with this section and NFPA 10. Comments:Provide required annual service to extinguishers,no Exceptions:1.The distance of travel to reach an extinguisher current contractor's tag or date reference to last service date.If shall not apply to the spectator seating portions of Group A-5 purchasing own extinguishers,tape receipt to bottom to use as occupancies.2.Thirty-day inspections shall not be required annual service date. and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 8/27/28, 7:48 AM 8 OF 9 ro Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $50.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/27/26, 7:48 AM 9 OF 9