HomeMy WebLinkAboutAMOS BARNING - 1422 SHADY LANE F W q r y� INVOICE DATE DUE DATE INVOICE # TOTAL DUE
fir t, 0 09/01/2026 10/05/2026 2027-00000045 $50.00
IA 0
• ' II III I I
4S7b► 1l‘3
Customer #: 25044 Please Make Check Payable and Remit To:
City of Waterloo
A TTN: City Clerk/Accounts Receivable
AMOS BARNING 715 Mulberry St
3949 Scenic Drive WATERLOO, IA 50703
WATERLOO, IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL PROP INSPECTION - 1422 SHADY LN-08/27/26 I FOR BILLING INQUIRY: (319)291-4323
1
Description Total Price
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE # CHARGES
25044 09/01/2026 10/05/2026 2027-00000045 $50.00
Less Prepayment $0.00
Total Due --* $50.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
010S -r1 , r1Q
Waterloo Fire Rescue
Inspection Report 3`74�1 5 ' 1
7 425 E.3rd Street
1422 Shady Lane-1422 Shady LN,Waterloo IA 50701-1912 L(ec Si) `U
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
08127/2026 2015 IPMC Rental Inspection REINSPECTION ] �/- �I a f 21909-R1
Lead Inspector Shift Station —�v Unit
Randy Girsch N/A N/A N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
0 0 0 4 0 4
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
Randy Girsch
09/29/2026
randy.girsch@waterloo-ia.org
GENERAL NOTES
Randy Girsch-08128/2026 @ 09:43
Property Safety Inspector Randy Girsch-319-961-1450 Re-inspection date is as posted on the inspection report given,the rental unit's responsible
person/s shall reach out prior to set time of that re-inspection.If all corrections are made before the scheduled inspection,you can call to set up an
earlier re-inspection.Please give the appropriate notices to occupants of the unit/s.Owner or owner's agent must be present during inspections.Failure
to schedule a time on the date given or failure to keep the inspection will result in a$100 fee.*****Re inspection fees may be assessed for reinspections.
Re-inspection fees start at S50,then$150,and$250 for all subsequent reinspections.All appropriate keys to gain entry to locked units shall be readily
available during re-inspection.
Randy Girsch-08128/2026 @ 10:10
Upon reinspection if this rental property I have found multiple corrections that have not been taken care of.This property was inspected by me on 04-16-
2026.This gave the owner of the property over 4 months to make the corrections.The owner has told me several times that he is too busy to get it done.I
have applied a$50.00 fee for not having corrections made prior to inspections.I have set the reinspection date for this address on Tuesday September
22nd 2026 at 9am.
SIGNATURES
Contact signature Inspector signature
No signature 'WA -)
Report completed post inspection
Amos Barning Date: Randy Girsch 08/28/2026
CHECKLISTS
GENERATED ON 8/28/28, 10:15 AM 1 OF 2
Reinspection
Status Code Description
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Basement in laundry room
maintained in good,clean and sanitary condition.Peeling, Comments:Flooring is breaking up and is a trip hazard.The linoleum
chipping,flaking or abraded paint shall be repaired,removed flooring needs to be replaced.
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
•
•
•
Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture
Location:Kitchen
Requirements
Plumbing fixtures shall be properly installed and maintained Comments:Sprayer head on sink not working.Needs to be replaced.
in working order,and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less Location:Living room
than two separate and remote receptacle outlets.Every Comments:All the receptacles I was able to test tested"Open
laundry area shall contain not less than one grounding-type Ground"All receptacles that test open ground need to be grounded,
receptacle or a receptacle with a ground fault circuit or have a two prong receptacle installed or a GFCI needs to be
interrupter.Every bathroom shall contain not less than one installed.
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less Location:Kitchen
than two separate and remote receptacle outlets.Every Comments:All the receptacles I was able to test tested"Open
laundry area shall contain not less than one grounding-type Ground"All receptacles that test open ground need to be grounded,
receptacle or a receptacle with a ground fault circuit or have a two prong receptacle installed or a GFCI needs to be
interrupter.Every bathroom shall contain not less than one installed.
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
2 OF 2
GENERATED ON 8/28/28, 18:15 AM