Loading...
HomeMy WebLinkAboutCALIBER MANAGEMENT - 1508 FRANKLIN STREET O F W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 09/01/2026 10/05/2026 2027-00000047 $50.00 • I. ■nmu u • ) ♦- ♦ 0 _ _ 7) 3s 7d10%� Customer#: 24620 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CALIBER MANAGEMENT 715 Mulberry St 622 PROGRESS AVE WATERLOO, IA 50703 STE B WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL PROP INSPECTION - 1508 FRANKLIN ST-08/20/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 1ST $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24620 09/01/2026 10/05/2026 2027-00000047 $50.00 Less Prepayment $0.00 Total Due -* $50.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. ?-1Cf 1141 -' Waterloo Fire Rescue (d')( I Inspection Report "7 425 E.3rd Street BLDG 1508 FRANKLIN ST-1508 Franklin ST,Waterloo IA 50703-4046 � S1 OLD P INSPECTION DETAILS Cz..vV om. JE- 647 Inspection Date Inspection Type 6 -1� s Inspection Number 08120/2026 2015 IPMC Rental Inspection REINSPECTION 22046-R1 Lead Inspector Shift Station Unit MIKE HEERKES N/A NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 00 018 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date MIKE HEERKES 09121/2026 mike.heerkes@waterloo-ia.org,3192914319 GENERAL NOTES MIKE HEERKES-08/20/2026 @ 11:06 $50.00 Re-Inspection fee has been issued due to lack of progress on noted deficiencies from initial inspection. MIKE HEERKES-05/04/2026 @ 14:28 All structural repairs,water heater replacement,furnace replacement and major electrical repairs require appropriate permits and inspections. MIKE HEERKES-05/04/2026 @ 14:28 Re-inspection date is as posted on the inspection report.The rental unit's responsible person/s shall contact prior to inspection date to set up time of re inspection,If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150, and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections. MIKE HEERKES-05/04/2026 @ 14:28 Iowa Administrative Code 661-210.3(7)d.After June 30,2021,a battery-powered smoke alarm listed in accordance with UL 217 that is newly installed or replaces an existing battery-powered smoke alarm must be powered by a nonremovable,non-replaceable battery that powers the alarm for at least ten years.The battery requirements of this subrule do not apply to a fire alarm,smoke detector,smoke alarm,or ancillary component that is electronically connected as a part of a centrally monitored or supervised alarm system;that uses a low-power,radio frequency wireless communication signal. SIGNATURES Contact signature Inspector signature No signature Report completedeel post inspection nspection Caliber Group Prop Mgmt Date: MIKE HEERKES 08/20/2026 CHECKLISTS GENERATED ON 8/20/26, 1:38 PM 1 OF 7 A Reinspection Status Code Description Fail 2015 IPMC 302.3-Sidewalks and driveways Sidewalks,walkways,stairs,driveways,parking spaces and Location:Front steps similar areas shall be kept in a proper state of repair,and Comments:Concrete extremely deteriorated causing trip and fall maintained free from hazardous conditions. hazard. plp F • fa.,r ; ye. r e . b .1 ( Y Fail 2015 IPMC 302.7-Accessory structures Accessory structures,including detached garages,fences Location:Detached Garage and walls,shall be maintained structurally sound and in good Comments:Front wall damaged causing structure to lean.Obtain repair. proper permits and inspections for repairs. Fail 2015 IPMC 304.13-Window,skylight and door frames Every window,skylight,door and frame shall be kept in Location:Bedroom#3 and front porch sound condition,good repair and weather tight. Comments:Window with broken glass Additional comments:Front porch-Glass was removed and replaced with screen Unable to access bedrooms to inspect. Fail 2015 IPMC 304.15-Doors Exterior doors,door assemblies,operator systems if Location:Front and rear entrances provided,and hardware shall be maintained in good Comments:Doors are not properly fitting in frames and latching condition.Locks at all entrances to dwelling units and areas in frame are deteriorated. sleeping units shall tightly secure the door.Locks on means of egress doors shall be in accordance with Section 702.3. Fail 2015 IPMC 304.3-Premises identification Buildings shall have approved address numbers placed in a Comments:Address is not visible due to tree obstruction and one of position to be plainly legible and visible from the street or the numbers is broken. road fronting the property.These numbers shall contrast with their background.Address numbers shall be Arabic numerals or alphabet letters.Numbers shall be not less than 4 inches (102 mm)in height with a minimum stroke width of 0.5 inch (12.7 mm). GENERATED ON 8/20/26, 1:38 PM 2 OF 7 Fail 2015 IPMC 304.6-Exterior walls Exterior walls shall be free from holes,breaks,and loose or Comments:Bottom siding panel not properly secured and hole in rotting materials;and maintained weatherproof and properly wall that needs to be sealed. surface coated where required to prevent deterioration. ,r,.,,, 1, :•:, 7 :7'1';''''''' ,. ,,, ;.. , ; : ,,,..,.:2.-i;i4:::.‘. ,t„."-,-;,,," t . dijw. -.. , '„,, ..i, !1,' ,e fitA VIP' - ''' '411 . 1 # Will Fail 2015 IPMC 304.7-Roofs and drainage The roof and flashing shall be sound,tight and not have Comments:Multiple downspouts without proper extensions to divert defects that admit rain.Roof drainage shall be adequate to water away from foundation. prevent dampness or deterioration in the walls or interior portion of the structure.Roof drains,gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Kitchen maintained in good,clean and sanitary condition.Peeling, Comments:Water staining on ceiling tiles.Confirm no active leaking chipping,flaking or abraded paint shall be repaired,removed from pipes above and replace tiles that are damaged. or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. Additional comments:At time of re-inspection,ceiling tiles sagging in two separate areas. Fail 2015 IPMC 305.6-Interior doors Every interior door shall fit reasonably well within its frame Location:Bedroom#1 and shall be capable of being opened and closed by being Comments:Door not able to be latched due to disrepair of frame properly and securely attached to jambs,headers or tracks as around latch plate. intended by the manufacturer of the attachment hardware. Additional comments:Unable to access bedrooms to inspect. GENERATED ON 8/20/26, 1:38 PM 3 OF 7 Fail 2015 IPMC 307.1-General-Handrails&Guards Every exterior and interior flight of stairs having more than Location:Front entrance four risers shall have a handrail on one side of the stair and Comments:Handrail not properly secured and decking missing. every open portion of a stair,landing,balcony,porch,deck, ramp or other walking surface that is more than 30 inches (762 mm)above the floor or grade below shall have guards. Handrails shall be not less than 30 inches(762 mm)in height or more than 42 inches(1067 mm)in height measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces.Guards shall be not less than 30 inches(762 mm)in height above the floor of the landing,balcony,porch,deck,or ramp or other walking surface. 't' tf * w ii�Tss �.Yi:� �;5: M. s,. phi . 4�f,. y , Sit" A,:fig t,,,.,,,, i r1., 1ii..t. d r. `, .,� ,,:,.-,*. Fail 2015 IPMC 309.1-Infestation Structures shall be kept free from insect and rodent Comments:Evidence of rodent activity throughout residence. infestation.Structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health.After pest elimination, proper precautions shall be taken to prevent reinfestation. Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture Requirements Location:Basement Plumbing fixtures shall be properly installed and maintained Comments:Shower facility not properly installed and is not currently in working order,and shall be kept free from obstructions, useable.Remove shower or repair with proper permits and leaks and defects and be capable of performing the function inspections. for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition GENERATED ON 8/20/26, 1:38 PM 4 OF 7 Fail 2015 IPMC 603.1-Mechanical appliances Mechanical appliances,fireplaces,solid fuel-burning Location:Basement appliances,cooking appliances and water heating appliances Comments:Ductwork above furnace has endcap partially unattached. shall be properly installed and maintained in a safe working condition,and shall be capable of performing the intended Additional comments:Furnace and AIC replaced.No permit on file function. and no inspection of installation.Furnace requires installation by licensed HVAC contractor with proper permits and inspections.At time of re-inspection fan was not able to be shut off. Etag 'F j T a ♦ t 1 # i � , f,�1f4111044 Fail 2015 IPMC 605.3-Luminaires Every public hall,interior stairway,toilet room,kitchen, Location:Stairway to 2nd floor and 2nd floor hallway bathroom,laundry room,boiler room and furnace room shall Comments:Wall light fixtures without appropriate globes/covers. contain not less than one electric luminaire.Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection. Fail 2015 IPMC 702.4-Emergency escape openings Required emergency escape openings shall be maintained in Location:Basement accordance with the code in effect at the time of construction, Comments:Egress window has broken window pane and the following.Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools.Bars,grilles,grates or similar devices are permitted to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the escape and rescue opening. GENERATED ON 8/20/26, 1:38 PM 5 OF 7 Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1 Single or multiple-station smoke alarms shall be installed and Location:Bedroom#1,#2 maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Required smoke detectors missing. occupant load at all of the following locations:1.On the ceiling or wall outside of each separate sleeping area in the Additional comments:Unable to access bedrooms to inspect. immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Basement Identified electrical hazards shall be abated.Identified Comments:Electrical service panel has breaker opening that needs hazardous electrical conditions in permanent wiring shall be to be properly secured. brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Garage Identified electrical hazards shall be abated.Identified Comments:Both exterior lights missing proper globes/covers. hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. GENERATED ON 8/20/26, 1:38 PM 6 OF 7 EStatement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $50.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/28/26, 1:38 PM 7 OF 7