HomeMy WebLinkAboutCALIBER MANAGEMENT - 1508 FRANKLIN STREET O F W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE
0 09/01/2026 10/05/2026 2027-00000047 $50.00
• I. ■nmu u •
) ♦- ♦ 0
_ _ 7)
3s 7d10%�
Customer#: 24620 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
CALIBER MANAGEMENT 715 Mulberry St
622 PROGRESS AVE WATERLOO, IA 50703
STE B
WATERLOO, IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL PROP INSPECTION - 1508 FRANKLIN ST-08/20/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24620 09/01/2026 10/05/2026 2027-00000047 $50.00
Less Prepayment $0.00
Total Due -* $50.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
?-1Cf 1141 -'
Waterloo Fire Rescue (d')(
I Inspection Report "7 425 E.3rd Street
BLDG 1508 FRANKLIN ST-1508 Franklin ST,Waterloo IA 50703-4046 � S1 OLD P
INSPECTION DETAILS Cz..vV om. JE- 647
Inspection Date Inspection Type 6 -1� s Inspection Number
08120/2026 2015 IPMC Rental Inspection REINSPECTION 22046-R1
Lead Inspector Shift Station Unit
MIKE HEERKES N/A NIA N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
00 018
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
MIKE HEERKES
09121/2026
mike.heerkes@waterloo-ia.org,3192914319
GENERAL NOTES
MIKE HEERKES-08/20/2026 @ 11:06
$50.00 Re-Inspection fee has been issued due to lack of progress on noted deficiencies from initial inspection.
MIKE HEERKES-05/04/2026 @ 14:28
All structural repairs,water heater replacement,furnace replacement and major electrical repairs require appropriate permits and inspections.
MIKE HEERKES-05/04/2026 @ 14:28
Re-inspection date is as posted on the inspection report.The rental unit's responsible person/s shall contact prior to inspection date to set up time of re
inspection,If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to
occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep
the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150,
and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections.
MIKE HEERKES-05/04/2026 @ 14:28
Iowa Administrative Code 661-210.3(7)d.After June 30,2021,a battery-powered smoke alarm listed in accordance with UL 217 that is newly installed or
replaces an existing battery-powered smoke alarm must be powered by a nonremovable,non-replaceable battery that powers the alarm for at least ten
years.The battery requirements of this subrule do not apply to a fire alarm,smoke detector,smoke alarm,or ancillary component that is electronically
connected as a part of a centrally monitored or supervised alarm system;that uses a low-power,radio frequency wireless communication signal.
SIGNATURES
Contact signature Inspector signature
No signature
Report completedeel post inspection
nspection
Caliber Group Prop Mgmt Date: MIKE HEERKES 08/20/2026
CHECKLISTS
GENERATED ON 8/20/26, 1:38 PM 1 OF 7
A
Reinspection
Status Code Description
Fail 2015 IPMC 302.3-Sidewalks and driveways
Sidewalks,walkways,stairs,driveways,parking spaces and Location:Front steps
similar areas shall be kept in a proper state of repair,and Comments:Concrete extremely deteriorated causing trip and fall
maintained free from hazardous conditions. hazard.
plp
F
• fa.,r
; ye.
r e
. b .1
( Y
Fail 2015 IPMC 302.7-Accessory structures
Accessory structures,including detached garages,fences Location:Detached Garage
and walls,shall be maintained structurally sound and in good Comments:Front wall damaged causing structure to lean.Obtain
repair. proper permits and inspections for repairs.
Fail 2015 IPMC 304.13-Window,skylight and door frames
Every window,skylight,door and frame shall be kept in Location:Bedroom#3 and front porch
sound condition,good repair and weather tight. Comments:Window with broken glass
Additional comments:Front porch-Glass was removed and replaced
with screen Unable to access bedrooms to inspect.
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Front and rear entrances
provided,and hardware shall be maintained in good Comments:Doors are not properly fitting in frames and latching
condition.Locks at all entrances to dwelling units and areas in frame are deteriorated.
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3.
Fail 2015 IPMC 304.3-Premises identification
Buildings shall have approved address numbers placed in a Comments:Address is not visible due to tree obstruction and one of
position to be plainly legible and visible from the street or the numbers is broken.
road fronting the property.These numbers shall contrast with
their background.Address numbers shall be Arabic numerals
or alphabet letters.Numbers shall be not less than 4 inches
(102 mm)in height with a minimum stroke width of 0.5 inch
(12.7 mm).
GENERATED ON 8/20/26, 1:38 PM 2 OF 7
Fail 2015 IPMC 304.6-Exterior walls
Exterior walls shall be free from holes,breaks,and loose or Comments:Bottom siding panel not properly secured and hole in
rotting materials;and maintained weatherproof and properly wall that needs to be sealed.
surface coated where required to prevent deterioration.
,r,.,,, 1, :•:, 7
:7'1';''''''' ,. ,,, ;.. , ; : ,,,..,.:2.-i;i4:::.‘. ,t„."-,-;,,," t
. dijw. -.. ,
'„,, ..i, !1,' ,e fitA VIP' - ''' '411
.
1 # Will
Fail 2015 IPMC 304.7-Roofs and drainage
The roof and flashing shall be sound,tight and not have Comments:Multiple downspouts without proper extensions to divert
defects that admit rain.Roof drainage shall be adequate to water away from foundation.
prevent dampness or deterioration in the walls or interior
portion of the structure.Roof drains,gutters and downspouts
shall be maintained in good repair and free from obstructions.
Roof water shall not be discharged in a manner that creates a
public nuisance.
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Kitchen
maintained in good,clean and sanitary condition.Peeling, Comments:Water staining on ceiling tiles.Confirm no active leaking
chipping,flaking or abraded paint shall be repaired,removed from pipes above and replace tiles that are damaged.
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected. Additional comments:At time of re-inspection,ceiling tiles sagging
in two separate areas.
Fail 2015 IPMC 305.6-Interior doors
Every interior door shall fit reasonably well within its frame Location:Bedroom#1
and shall be capable of being opened and closed by being Comments:Door not able to be latched due to disrepair of frame
properly and securely attached to jambs,headers or tracks as around latch plate.
intended by the manufacturer of the attachment hardware.
Additional comments:Unable to access bedrooms to inspect.
GENERATED ON 8/20/26, 1:38 PM 3 OF 7
Fail 2015 IPMC 307.1-General-Handrails&Guards
Every exterior and interior flight of stairs having more than Location:Front entrance
four risers shall have a handrail on one side of the stair and Comments:Handrail not properly secured and decking missing.
every open portion of a stair,landing,balcony,porch,deck,
ramp or other walking surface that is more than 30 inches
(762 mm)above the floor or grade below shall have guards.
Handrails shall be not less than 30 inches(762 mm)in height
or more than 42 inches(1067 mm)in height measured
vertically above the nosing of the tread or above the finished
floor of the landing or walking surfaces.Guards shall be not
less than 30 inches(762 mm)in height above the floor of the
landing,balcony,porch,deck,or ramp or other walking
surface.
't'
tf * w
ii�Tss �.Yi:� �;5:
M.
s,.
phi .
4�f,. y ,
Sit"
A,:fig t,,,.,,,, i r1., 1ii..t. d r. `, .,� ,,:,.-,*.
Fail 2015 IPMC 309.1-Infestation
Structures shall be kept free from insect and rodent Comments:Evidence of rodent activity throughout residence.
infestation.Structures in which insects or rodents are found
shall be promptly exterminated by approved processes that
will not be injurious to human health.After pest elimination,
proper precautions shall be taken to prevent reinfestation.
Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture
Requirements Location:Basement
Plumbing fixtures shall be properly installed and maintained Comments:Shower facility not properly installed and is not currently
in working order,and shall be kept free from obstructions, useable.Remove shower or repair with proper permits and
leaks and defects and be capable of performing the function inspections.
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
GENERATED ON 8/20/26, 1:38 PM 4 OF 7
Fail 2015 IPMC 603.1-Mechanical appliances
Mechanical appliances,fireplaces,solid fuel-burning Location:Basement
appliances,cooking appliances and water heating appliances Comments:Ductwork above furnace has endcap partially unattached.
shall be properly installed and maintained in a safe working
condition,and shall be capable of performing the intended Additional comments:Furnace and AIC replaced.No permit on file
function. and no inspection of installation.Furnace requires installation by
licensed HVAC contractor with proper permits and inspections.At
time of re-inspection fan was not able to be shut off.
Etag
'F
j
T
a ♦ t
1
#
i
� ,
f,�1f4111044
Fail 2015 IPMC 605.3-Luminaires
Every public hall,interior stairway,toilet room,kitchen, Location:Stairway to 2nd floor and 2nd floor hallway
bathroom,laundry room,boiler room and furnace room shall Comments:Wall light fixtures without appropriate globes/covers.
contain not less than one electric luminaire.Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 702.4-Emergency escape openings
Required emergency escape openings shall be maintained in Location:Basement
accordance with the code in effect at the time of construction, Comments:Egress window has broken window pane
and the following.Required emergency escape and rescue
openings shall be operational from the inside of the room
without the use of keys or tools.Bars,grilles,grates or
similar devices are permitted to be placed over emergency
escape and rescue openings provided the minimum net clear
opening size complies with the code that was in effect at the
time of construction and such devices shall be releasable or
removable from the inside without the use of a key,tool or
force greater than that which is required for normal operation
of the escape and rescue opening.
GENERATED ON 8/20/26, 1:38 PM 5 OF 7
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location:Bedroom#1,#2
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Required smoke detectors missing.
occupant load at all of the following locations:1.On the
ceiling or wall outside of each separate sleeping area in the Additional comments:Unable to access bedrooms to inspect.
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 603.2-Abatement of unsafe conditions and electrical
hazards. Location:Basement
Identified electrical hazards shall be abated.Identified Comments:Electrical service panel has breaker opening that needs
hazardous electrical conditions in permanent wiring shall be to be properly secured.
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Fail 603.2-Abatement of unsafe conditions and electrical
hazards. Location:Garage
Identified electrical hazards shall be abated.Identified Comments:Both exterior lights missing proper globes/covers.
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
GENERATED ON 8/20/26, 1:38 PM 6 OF 7
EStatement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $50.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 8/28/26, 1:38 PM 7 OF 7