COMMERCIAL FIRE INSPECTION- 1850 W RIDGEWAY AVE- FOR BILLING INQUIRY: (319)291-4323
09/02/26
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23310 09/17/2026 10/22/2026 2027-00000110 $80.00
Less Prepayment $0.00
Total Due—> $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
i j;.. k Inspection Report
425 E.3rd Street
1850 Patio Grill-1850 W Ridgeway AVE,BLDG 1850 W Ridgeway Ave-STE 5,
Waterloo IA 50701
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
09102J2026 Annual Inspection(1Yr) �0 �Q' 18991
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A N/A NIA
Other Inspectors
NIA
SUMMARY OF INSPECTION
054 � 7 ® 15
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN 10101/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-09104/2026 @ 07:42
•$80 annual inspection fee
BRAD BALDWIN-09104/2026 @ 07:42
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224
BRAD BALDWIN-09104/2026 @ 07:42
•Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-09/04/2026 @ 07:43
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
BRAD BALDWIN-09104/2026 @ 08:02
Kitchen hood suppression system:Required bi-annual inspection due 9/25/26 including uploaded report to Compliance Engine with all deficiencies
corrected.
BRAD BALDWIN-09/04/2026 @ 08:01
Extinguishers due annually serviced in April 2027
BRAD BALDWIN-09/04/2026 @ 08:03
Corrected during 9/2/26 inspection:(1)Removed obstruction to fire alarm pull station near back exit kitchen.
SIGNATURES
Contact signature Inspector signature
No signature
GENERATED ON 9/10/26, 6:22 AM 1 OF 5
Report completed post inspection
Gina Haan Date: -
CHECKLISTS
Fire Sprinkler System
St itus Cork Description
Fail 903.3.3-Obstructed locations.
Automatic sprinklers shall be installed with regard to Location:Walk-in freezer
obstructions that will delay activation or obstruct the water Comments:Remove storage(boxes)above freezer obstructing
distribution pattern and shall be in accordance with the sprinkler head coverage.
applicable automatic sprinkler system standard that is being
used.Automatic sprinklers shall be installed in or under
covered kiosks,displays,booths,concession stands or
equipment that exceeds 4 feet(1219 mm)in width.Not less
than a 3-foot(914 mm)clearance shall be maintained between
automatic sprinklers and the top of piles of combustible
fibers.Exception:Kitchen equipment under exhaust hoods
protected with a fire-extinguishing system in accordance with
Section 904.
GENERATED ON 9/10/26, 8:22 AN 2 OF 5
Additional Codes
Status Code Description
Fail 5303.5.3-Securing compressed gas containers,cylinders
and tanks. Location:Bar
Compressed gas containers,cylinders and tanks shall be Comments:Secure all compressed gas cylinders with chain to avoid
secured to prevent falling caused by contact,vibration or tip over.
seismic activity.Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers,cylinders and tanks to a fixed object
with one or more restraints.2.Securing containers,cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers,cylinders or tanks.
3.Nesting of compressed gas containers,cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public.Nesting shall be allowed
provided that the nested containers,cylinders or tanks,if
dislodged,do not obstruct the required means of egress.
4.Securing of compressed gas containers,cylinders and
tanks to or within a rack,framework,cabinet or similar
assembly designed for such use.Exception:Compressed gas
containers,cylinders and tanks in the process of
examination,filling,transport or servicing.
Fail 904.13-Commercial cooking systems.
The automatic fire-extinguishing system for commercial Location:Kitchen hood suppression system
cooking systems shall be of a type recognized for protection Comments:Suppression head covers(2)missing above 6-burner
of commercial cooking equipment and exhaust systems of range shall be installed to avoid the accumulation of grease on
the type and arrangement protected.Preengineered heads.
automatic dry-and wet-chemical extinguishing systems shall
be tested in accordance with UL 300 and listed and labeled
for the intended application.Other types of automatic fire-
extinguishing systems shall be listed and labeled for specific
use as protection for commercial cooking operations.The
system shall be installed in accordance with this code,NFPA
96,its listing and the manufacturer's installation instructions.
Automatic fire-extinguishing systems of the following types
shall be installed in accordance with the referenced standard
indicated,as follows:1.Carbon dioxide extinguishing
systems,NFPA 12.2.Automatic sprinkler systems,NFPA 13.
3.Automatic water mist systems,NFPA 750.4.Foam-water
sprinkler system or foam-water spray systems,NFPA 16.
5.Dry-chemical extinguishing systems,NFPA 17.6.Wet-
chemical extinguishing systems,NFPA 17A.Exception:
Factory-built commercial cooking recirculating systems that
are tested in accordance with UL 710B and listed,labeled and
installed in accordance with Section 304.1 of the International
Mechanical Code.
GENERATED ON 9/18/26, 8:22 AM 3 OF 5
Electrical Safety
Status Code Description
Fail 603.4.1-Labeling.
ODoors into electrical control panel rooms shall be marked Location:Kitchen-mechanical room
with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide permanent approved signage on door indicating
ROOM"or similar approved wording.The disconnecting "ELECTRICAL PANEL"or other approved wording.Paper or
means for each service,feeder or branch circuit originating laminated paper will not be accepted.
on a switchboard or panelboard shall be legibly and durably
marked to indicate its purpose unless such purpose is clearly
evident.Where buildings or structures are supplied by more
than one power source,markings shall be provided at each
service equipment location and at all interconnected electric
power production sources identifying all electric power
sources at the premises in accordance with NFPA 70.
Fail 603.5-Relocatable power taps and current taps.Multiplug
adapters. Location:Server area
Multiplug adapters,such as cube adapters,unfused plug Comments:Multi-plug adapter below"YUENGLING"neon sign shall
strips or any other device not complying with NFPA 70 shall be removed,would approved replacing with properly mounted power
be prohibited.The construction and use of current taps and strip with manual reset for low wattage electronics only.
relocatable taps shall be in accordance with NFPA 70 and this
code.
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Bar-near CO2 tanks
for permanent wiring and shall be listed and labeled in Comments:Flexible supply cords(2-white cords for under bar
accordance with UL 817.Extension cords and flexible lighting)extending through and into bar wall shall be corrected.
cordsshall not be affixed to structures,extended through Flexible wiring shall not pass through concealed spaces.
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Bar I Soda Fountain Machine
for permanent wiring and shall be listed and labeled in Comments:Flexible pump supply cord passing through wall shall be
accordance with UL 817.Extension cords and flexible corrected.Flexible wiring shall not pass through concealed spaces
cordsshall not be affixed to structures,extended through (walls,ceilings or floors).
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
GENERATED ON 9/16/26,8:22 All 4 OF 5