Loading...
HomeMy WebLinkAbout1850 PATIO GRILL - 1850 W RIDGEWAY AVE 4f WA r4% INVOICE DATE DUE DATE INVOICE# TOTAL DUE '` � o Pe I. 09/17/2026 10/22/2026 2027-00000110 $80.00 / /A o . 'n n le to II . > T--- T 0 4S 7vil‘ Customer#: 23310 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 1850 PATIO GRILL 715 Mulberry St 1850 W RIDGEWAY AVE WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1850 W RIDGEWAY AVE- FOR BILLING INQUIRY: (319)291-4323 09/02/26 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23310 09/17/2026 10/22/2026 2027-00000110 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue i j;.. k Inspection Report 425 E.3rd Street 1850 Patio Grill-1850 W Ridgeway AVE,BLDG 1850 W Ridgeway Ave-STE 5, Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 09102J2026 Annual Inspection(1Yr) �0 �Q' 18991 Lead Inspector Shift Station Unit BRAD BALDWIN N/A N/A NIA Other Inspectors NIA SUMMARY OF INSPECTION 054 � 7 ® 15 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 10101/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09104/2026 @ 07:42 •$80 annual inspection fee BRAD BALDWIN-09104/2026 @ 07:42 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-09104/2026 @ 07:42 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-09/04/2026 @ 07:43 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-09104/2026 @ 08:02 Kitchen hood suppression system:Required bi-annual inspection due 9/25/26 including uploaded report to Compliance Engine with all deficiencies corrected. BRAD BALDWIN-09/04/2026 @ 08:01 Extinguishers due annually serviced in April 2027 BRAD BALDWIN-09/04/2026 @ 08:03 Corrected during 9/2/26 inspection:(1)Removed obstruction to fire alarm pull station near back exit kitchen. SIGNATURES Contact signature Inspector signature No signature GENERATED ON 9/10/26, 6:22 AM 1 OF 5 Report completed post inspection Gina Haan Date: - CHECKLISTS Fire Sprinkler System St itus Cork Description Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Walk-in freezer obstructions that will delay activation or obstruct the water Comments:Remove storage(boxes)above freezer obstructing distribution pattern and shall be in accordance with the sprinkler head coverage. applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. GENERATED ON 9/10/26, 8:22 AN 2 OF 5 Additional Codes Status Code Description Fail 5303.5.3-Securing compressed gas containers,cylinders and tanks. Location:Bar Compressed gas containers,cylinders and tanks shall be Comments:Secure all compressed gas cylinders with chain to avoid secured to prevent falling caused by contact,vibration or tip over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Fail 904.13-Commercial cooking systems. The automatic fire-extinguishing system for commercial Location:Kitchen hood suppression system cooking systems shall be of a type recognized for protection Comments:Suppression head covers(2)missing above 6-burner of commercial cooking equipment and exhaust systems of range shall be installed to avoid the accumulation of grease on the type and arrangement protected.Preengineered heads. automatic dry-and wet-chemical extinguishing systems shall be tested in accordance with UL 300 and listed and labeled for the intended application.Other types of automatic fire- extinguishing systems shall be listed and labeled for specific use as protection for commercial cooking operations.The system shall be installed in accordance with this code,NFPA 96,its listing and the manufacturer's installation instructions. Automatic fire-extinguishing systems of the following types shall be installed in accordance with the referenced standard indicated,as follows:1.Carbon dioxide extinguishing systems,NFPA 12.2.Automatic sprinkler systems,NFPA 13. 3.Automatic water mist systems,NFPA 750.4.Foam-water sprinkler system or foam-water spray systems,NFPA 16. 5.Dry-chemical extinguishing systems,NFPA 17.6.Wet- chemical extinguishing systems,NFPA 17A.Exception: Factory-built commercial cooking recirculating systems that are tested in accordance with UL 710B and listed,labeled and installed in accordance with Section 304.1 of the International Mechanical Code. GENERATED ON 9/18/26, 8:22 AM 3 OF 5 Electrical Safety Status Code Description Fail 603.4.1-Labeling. ODoors into electrical control panel rooms shall be marked Location:Kitchen-mechanical room with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide permanent approved signage on door indicating ROOM"or similar approved wording.The disconnecting "ELECTRICAL PANEL"or other approved wording.Paper or means for each service,feeder or branch circuit originating laminated paper will not be accepted. on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.5-Relocatable power taps and current taps.Multiplug adapters. Location:Server area Multiplug adapters,such as cube adapters,unfused plug Comments:Multi-plug adapter below"YUENGLING"neon sign shall strips or any other device not complying with NFPA 70 shall be removed,would approved replacing with properly mounted power be prohibited.The construction and use of current taps and strip with manual reset for low wattage electronics only. relocatable taps shall be in accordance with NFPA 70 and this code. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Bar-near CO2 tanks for permanent wiring and shall be listed and labeled in Comments:Flexible supply cords(2-white cords for under bar accordance with UL 817.Extension cords and flexible lighting)extending through and into bar wall shall be corrected. cordsshall not be affixed to structures,extended through Flexible wiring shall not pass through concealed spaces. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Bar I Soda Fountain Machine for permanent wiring and shall be listed and labeled in Comments:Flexible pump supply cord passing through wall shall be accordance with UL 817.Extension cords and flexible corrected.Flexible wiring shall not pass through concealed spaces cordsshall not be affixed to structures,extended through (walls,ceilings or floors). walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 9/16/26,8:22 All 4 OF 5 5 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/18/26, 8:22 AM 5 OF 5