COMMERCIAL FIRE INSPECTION- 1604 LA PORTE RD-09/17/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
REINSPECTION 1 $100.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
14658 09/17/2026 10/22/2026 2027-00000117 $100.00
Less Prepayment $0.00
Total Due—* $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
425 E.3rd Street
,< a Casey's General Store#2880-1604 La Porte RD,BLDG 1604 La Porte Rd,Waterloo
IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
0911712026 Annual Inspection(1Yr) REINSPECTION, �co 17583-R2
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A NIA N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
0 O 0 3 0 6
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN 1010812026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-09117/2026 @ 14:07
S100 re-inspection fee for failure to complete all corrections on scheduled 9117/26 inspection.Complete corrections to avoid fees at following inspections.
BRAD BALDWIN-0812712026 @ 10:56
•$80 annual inspection fee
BRAD BALDWIN-0842712026 @ 10:56
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224
BRAD BALDWIN-0812712026 @ 10:56
•Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-0812712026 @ 10:56
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at S100,then$150,and$200 for all subsequent re-inspections.
BRAD BALDWIN-08127/2026 @ 10:56
Withholding re-inspection fee on 8127126,complete corrections to avoid fees at following inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Kraig Miller 2026-Sevice Dept Date: BRAD BALDWIN 09117/2026
GENERATED ON 9/17/20, 2:09 PM 1 OF 6
CHECKLISTS
GENERATED ON 9/17/26, 2:09 PM 2 OF 6
Reinspection
Sia1u code Description
Fail 1010.2.4•Locks and latches.
Locks and latches shall be permitted to prevent operation of Location:Front exit door
doors where any of the following exist:1.Places of detention Comments:Install signage compliant to code"THIS DOOR TO
or restraint.2.In Group I.1,Condition 2 and Group I-2 REMAIN UNLOCKED DURING BUSINESS HOURS"on interior of
occupancies where the clinical needs of persons receiving doors in approved location.
care require containment or where persons receiving care
pose a security threat,provided that all clinical staff can Additional comments:Management stated doors are to be replaced.
readily unlock doors at all times,and all such locks are keyed Replacement of required exit doors require permit and inspection
to keys carried by all clinical staff at all times or all clinical obtained.
staff have the codes or other means necessary to operate the
locks at all times.2.3.In buildings in occupancy Group A
having an occupant load of 300 or less,Groups B,F,M and S,
and in places of religious worship,the main door or doors are
permitted to be equipped with key-operated locking devices
from the egress side provided:2.1.3.1.The locking device is
readily distinguishable as locked.2.2.3.2.A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch
(25 mm)high on a contrasting background.2.3.3.3.The use
of the key-operated locking device is revocable by the fire
code official for due cause.3.4.Where egress doors are used
in pairs,approved automatic flush bolts shall be permitted to
be used,provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface-mounted
hardware.4.5.Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch,dead
bolt or security chain,provided such devices are openable
from the inside without the use of a key or tool.5.6.Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures.6.7.Doors serving roofs not intended to be
occupied shall be permitted to be locked,preventing entry to
the building from the roof.8.Other than egress courts,where
occupants must egress from an exterior space through the
building for means of egress,exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following:8.1.The maximum occupant load shall be posted
where required by Section 1004.9.Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways.8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side.8.3.The egress door locking
device is readily distinguishable as locked and shall be a key-
operated locking device.8.4.A clear window or glazed door
opening,not less than 5 square feet(0.46 m2)in area,shall
be provided at each exit access door to determine if there are
occupants using the outdoor area.8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating:"THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on
the sign shall be not less than 1 inch(25.4 mm)high on a
contrasting background.8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004.9.Locking devices are
permitted on doors to balconies,decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet(23.23
m2)or less,serving a private office space,
GENERATED OM 9/17/26, 2:09 PM 3 OF 6
Fail 102.4-Application of building code.
The design and construction of new structures shall comply Location:Water heater
with the International Building Code,and any alterations, Comments:Licensed contractor shall obtain permit and inspection
additions,changes in use or changes in structures required for water heater installed without permit.
by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith. Additional comments:No permit in system on 9117126
1 . •
off/
,l'�itecie
Fit
Fail 102.4-Application of building code.
The design and construction of new structures shall comply Location:Used cooking oil storage tank
with the International Building Code,and any alterations, Comments:Licensed electrical contractor shall obtain permit and
additions,changes in use or changes in structures required inspection for receptacle added without permit.
by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith. Additional comments:No permit in system on 9117126
Fail 304.3.1-Spontaneous ignition.
Materials susceptible to spontaneous ignition,such as oily Location:Kitchen
rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container with self closing lid for disposal
of such containers shall be removed and disposed of daily. of soiled rags.Rags and towels soiled with fats,oils or grease shall
not be disposed of in the trash.
0111111
•
• • r
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
Open junction boxes and open-wiring splices shall be Location:Exterior outlets(2)next to Ice Freezer
prohibited.Approved covers shall be provided for all switch Comments:Replacing missing weather rated outlet covers.
and electrical outlet boxes.
GENERATED ON 9/17/26, 2:09 PM 4 OF 6
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Ice cream freezer near front exit
for permanent wiring and shall be listed and labeled In Comments:Remove extension cord plugged to freezer.Appliance
accordance with UL 817.Extension cords and flexible shall plug directly to a permanent outlet,extension cords shall not be
cordsshall not be affixed to structures,extended through used as permanent wiring.
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.