Loading...
HomeMy WebLinkAboutGREENHOUSE KITCHEN-1730 W RIDGEWAY AVE OF W A P INVOICE DATE DUE DATE INVOICE# TOTAL DUE 09/17/2026 10/22/2026 2027-00000127 $100.00 / o • •111 1 11 III 1 11 • 6�S71d17�� Customer#: 23829 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable GREENHOUSE KITCHEN 715 Mulberry St PO BOX 708 WATERLOO, IA 50703 CEDAR FALLS,IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1730 W RIDGEWAY AVE- FOR BILLING INQUIRY: (319)291-4323 09/16/26 Description Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23829 09/17/2026 10/22/2026 2027-00000127 $100.00 Less Prepayment $0.00 Total Due—> $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street Greenhouse Kitchen-1730 W Ridgeway AVE,BLDG 1730 W Ridgeway Ave-STE 500,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type n� Inspection Number 0911612026 Annual Inspection(1Yr) i REINSPECTION) 53S j, 7865-R2 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 0 6 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 10/1612026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09/16/2026 @ 13:58 $100 re-inspection fee due to lack of progress or completion of corrections on 9/16/26.Complete corrections to avoid fees at following inspections. BRAD BALDWIN-08/18/2026 @ 12:01 •680 annual inspection fee BRAD BALDWIN-08118/2026 @ 12:01 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(45)-Cell:319-230-1224 BRAD BALDWIN-08118/2026 @ 12:01 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m..".Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-0811812026 @ 12:01 Manager on-site stated the restaurant does not create grease,therefor no grease containment is needed.Creating grease in the future will require purchasing and using a listed grease container with self-closing lid. BRAD BALDWIN-0811812026 @ 12:01 Withholding re-inspection fee on 8/18/26 due to progress,complete corrections to avoid fees at following inspections. SIGNATURES Contact signature Inspector signature No signature inspection Report completed post Riley Luppen Date: BRAD BALDWIN 09116/2026 GENERATED ON 9/16/20, 2:03 PM t OF 0 CHECKLISTS GENERATED ON 9/16/2G, 2:03 PM 2 OF 4 Reinspection Status Code nescripfion Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Above door to bathroom hallway Illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights on exit sign that failed to illuminate during test. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Dining area illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights(2)on exit sign that failed to illuminate during test. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Men's bathroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights on exit sign that failed to illuminate during test.Was not able to access woinen's bathroom during 7114126 inspection,lights shall be tested and repaired if not functioning properly Additional comments:Women's restroom egress-OK.Men's bathroom egress light still tailed on 9116126. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Bathroom hallway illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights on exit sign that failed to illuminate during test. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not he a substitute Location:Menu TVs for permanent wiring and shall be listed and labeled in Comments:Extension cord shall be removed from plugged to TVs. accordance with UL 817.Extension cords and flexible Would approve the use of a properly mounted power strip with cordsshall not be affixed to structures,extended through manual reset for low wattage electronics only. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide annual service to all extinguishers,currently Exceptions:1.The distance of travel to reach an extinguisher past due for service since Oct 2025. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3,1n Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 6/16/26, 2:03 PM 3 OF 4 0 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/16/26, 2:03 PM 4 OF 4