Loading...
HomeMy WebLinkAboutHY-VEE FAST & FRESH-3700 UNIVERSITY AVE W 4 y. INVOICE DATE DUE DATE INVOICE # TOTAL DUE , 09/17/2026 10/22/2026 2027-00000128 $80.00 /A 0 • • 1 11 11 1 111 • vir 0 o* 'I V I I, Customer #: 22164 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts. Receivable HY-VEE GAS 715 Mulberry St 3700 UNIVERSITY AVE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 3 700 UNIVERSITY AVE- FOR BILLING INQUIRY: (319)291-4323 09/01/26 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22164 09/17/2026 10/22/2026 2027-00000128 $80.00 Less Prepayment $0.00 Total Due - › $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street Hy-Vee Fast and Fresh•3700 University AVE,BLDG 3700 University Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date „ : Inspection Number 0910112026 Annual Inspection(1Yr) .221 4.. _-_ _ � 18791 Lead Inspector Sliih Station Unit BRAD BALDWIN NIA NIA NIA Otherinstectors NIA SUMMARY OF INSPECTION 042 8 ® 26 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0912312026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0910 212026 @ 08:07 •$80 annual inspection fee BRAD BALDWIN-0910212026 @ 08:07 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-0910212026 @ 08:07 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-0910212026 @ 08:07 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-09102/2026 @ 08:08 Fire extinguishers due annually serviced in August 2027 SIGNATURES Contact signature Inspector signature No signature Report completedetl post inspection nspection Corrine Winters Date: BRAD BALDWIN 09102/2026 CHECKLISTS GENERATED ON B/2/26,8:33 AN 1 or s Emergency Equipment Status Code Description Fail 1203.2.15 - Means of egress illumination. Ox Emergency power shall be provided for means of egress Location: Back storage - above thermostat illumination in accordance with Sections 1008.3 and 1104.5.1. Comments: Repair or replace emergency egress light that failed to illuminate during test. Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress Location: Women's Bathroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments: Repair or replace emergency egress light that failed to illuminate during test Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required Location: Main exit door near registers in Section 1013.6.3. The system shall be capable of powering Comments: Exit sign and egress lights combo very dull when tested. the required load for a duration of not less than 90 minutes. Additional Codes Status Code Description Fail 2303.2 - Emergency disconnect switches. 0 An approved emergency disconnect switch shall be provided Location: Interior gas Emergency Fuel Shutoff at an approved location to stop the transfer of fuel to the fuel Comments: Provide permanent signage indicating location of Fuel dispensers in the event of a fuel spill or other emergency. The Shutoff button in an approved location. Signage shall include white emergency disconnect switch for exterior fuel dispensers lettering with red background, laminated paper will not be accepted. shall be provided with ready access and shall be located within 100 feet (30 480 mm) of, but not less than 20 feet (6096 mm) from, the fuel dispensers. For interior fuel-dispensing operations, the emergency disconnect switch shall be provided with ready access and be installed at an approved location. Such devices shall be distinctly labeled as: "EMERGENCY FUEL SHUTOFF." Signs shall be provided in approved locations. Fail 6107.3 - Clearance to combustibles. Weeds, grass, brush, trash and other combustible materials Location: East exterior - LP tanks cabinet shall be kept not less than 10 feet (3048 mm) from LP-gas Comments: Pile of pallets and all combustible materials shall be tanks or containers. relocated from within 10 ft of LP tanks cabinet. GENERATED ON 8/2/26, 8:33 AM 2 OF 5 Electrical Safety Status Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Electric panels prohibited.Approved covers shall be provided for all switch Comments:Install missing gutter cover to avoid exposed wires. and electrical outlet boxes. T � Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Electric panels equipment shall be provided in accordance with Section Comments:Remove storage within 36"in front of panels,maintain 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or this area clear of storage at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). •: • •" • • GENERATED ON 0/2/26, 8:33 AM 3 OF 5 Portable Fire Extingusihers ' Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Back storage desk maintained in accordance with this section and NFPA 10. Comments:Spare extinguisher last serviced in 2013.All Exceptions:1.The distance of travel to reach an extinguisher extinguishers in building shall be serviced annually and mounted on shall not apply to the spectator seating portions of Group A-5 wall bracket at required locations or removed from building if not a occupancies.2.Thirty-day inspections shall not be required required extinguisher. and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 9/2/26, 8:33 AM 4 DF 5 Fo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/2/26, 8:33 AM 5 OF 5