Loading...
HomeMy WebLinkAboutMASSAGE STUDIO-351 FLETCHER AVE OF W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 1 09/17/2026 10/22/2026 2027-00000135 $80.00 u.,riiir�+•." /A O • •111 111 1 1 11 11 • T-= 0 'Ss 7v11‘ Customer#: 23344 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MASSAGE STUDIO 715 Mulberry St 351 FLETCHER AVE WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-351 FLETCHER AVE-09/15/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23344 09/17/2026 10/22/2026 2027-00000135 $80.00 Less Prepayment $0.00 Total Due—+ $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street "`"• Massage Studio-351 Fletcher AVE, BLDG 351 Fletcher Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0911512026 Annual Inspection(1Yr) ✓ 3848 Lead Inspector Shift Station Unit BRAD BALDWIN NIA N/A NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 30 0 17 @ 38 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 10/1612026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09/17/2026 @ 12:35 •$80 annual inspection fee BRAD BALDWIN-09/17/2026 @ 12:36 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-09117/2026 @ 12:36 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Suchen-2026 Date: BRAD BALDWIN 09/17/2026 CHECKLISTS GENERATED ON 9/17/28, 12:40 PM 1 OF 11 Means of Egress Status Code Desonoon Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Basement-West exit continuously maintained free from obstructions or Comments:Remove board from base of exit door,maintain impediments to full instant use in the case of fire or other unobstructed egress path through exit at all times. emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. , EIT ,,r�, rI iti 4 / A., - _, _ _ , f.4 E `.:cY r GENERATED ON 9/17/26, 12:48 PM 2 OF 11 Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Basement•North exit continuously maintained free from obstructions or Comments:Required exit doors shall be maintained free from impediments to full instant use in the case of fire or other obstructed at all times.Current occupancy does not require this emergency where the building area served by the means of second exit,options are as follows:(1)Remove cable lock from door egress is occupied.An exit or exit passageway shall not be and maintain exit free of obstructions(2)Remove exit sign above used for any purpose that interferes with a means of egress. basement door leading to this exit including capping electrical wires of exit sign and containing in box with cover,other exit sign in basement to remain.Cable lock remaining on door will require approved permanent signage installed on exterior of door indicating "THIS DOOR BLOCKED" iI 0101 11112 I ill I II GENERATED ON 9/17/26, 12:40 PM s of i. Additional Codes Status Code Description Fail 102.3-Change of use or occupancy. A change of occupancy shall not be made unless the use or Location:Basement occupancy is made to comply with the requirements of this Comments:Remove bed from building immediately,sleeping not an code and the International Existing Building Code. approved use in commercial space. Exception:Where approved by the fire code official,a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code,provided that the new or proposed use or occupancy is less hazardous,based on life and fire risk,than the existing use or occupancy. Oti Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Air Conditioner with the International Building Code,and any alterations, Comments:Contractor(Bergen Plumbing,Heating&Cooling)shall additions,changes in use or changes in structures required obtain inspection of AIC installed.Record of Bergen obtaining permit by this code,which are within the scope of the International but failed to obtain inspection. Building Code,shall be made in accordance therewith. GENERATED ON 9/17/26, 12:46 PM 4 OF 11 Fail 1032.6-Finishes,furnishings and decorations. Means of egress doors shall be maintained in such a manner Location:Basement as to be distinguishable from the adjacent construction and Comments:Remove curtain from exit door,required exit doors may finishes such that the doors are easily recognizable as doors. not be disguised. Furnishings,decorations or other objects shall not be placed so as to obstruct exits,access thereto,egress therefrom,or visibility thereof.Hangings and draperies shall not be placed over exit doors or otherwise be located to conceal or obstruct an exit.Mirrors shall not be placed on exit doors.Mirrors shall not be placed in or adjacent to any exit in such a manner as to confuse the direction of egress. ............ ... .I am «ALI 101 . l wi Fail 308.1.7.1-Aisles and exits. Candles shall be prohibited in areas where occupants stand, Location:Large massage room or in an aisle or exit. Comments:Candle shall be re-located away from wall and away from walk path to avoid potential of tip-over. t i 5 OF 11 GENERATED ON G/17/20, 12:40 PM Fail 310.1-General. The smoking or carrying of a lighted pipe,cigar,cigarette or Location:North end stairs to basement any other type of smoking paraphernalia or material is Comments:Smoking is strictly prohibited inside the building.Staff prohibited in the areas indicated in Sections 310.2 through on-site during 9115126 inspection admitted to smoking in stairwell on 310.8. continuous basis.Also noted,walls show obvious sign of smoking and jar of used cigarettes found. Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Small massage room code or the International Building Code shall be installed, Comments:Remove microwave used and maintained in accordance with NFPA 70 and plugged rssh to power strip.Appliances Sections 603.2 through 603.10. including heating elements or motors shall plug directly to a permanent outlet. Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Small massage room code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Comments:Heat pad shall be removed from plugged to power strip. Sections 603.2 through actor 603.10. Appliances including heating elements or motors shall plug directly to a permanent outlet. ,x GENERATED ON 0/17/26, 12:40 PM 6 OF 11 Fail 807.3-Acceptance criteria and reports. (";-'r Where required to exhibit improved fire performance, Location:Entire building curtains,draperies,fabric hangings and other similar Comments:Provide documentation of all curtains and draperies combustible decorative materials suspended from walls or throughout building have been tested and meet required Flame ceilings shall be tested by an approved agency and meet the Spread criteria.Curtains and draperies that do not meet required flame propagation performance criteria of Test Method 1 or criteria shall be removed. Test Method 2,as appropriate,of NFPA 701 or exhibit a maximum rate of heat release of 100 kW when tested in accordance with NFPA 289,using the 20 kW ignition source. Reports of test results shall be prepared in accordance with the test method used and furnished to the fire code official upon request. 4' „ Fail 907.10-Smoke alarm maintenance. Smoke alarms shall be tested and maintained in accordance Location:Large massage room with the manufacturer's instructions.Smoke alarms shall be Comments:Replace smoke detector more than 10 years old replaced when they fail to respond to operability tests,or when they exceed 10 years from the date of manufacture, unless an earlier replacement is specified in the manufacturer's published instructions. 7 OF 11 GENERATE6 ON 5i/17/26, 12:40 PM Electrical Safety Stat.i_. Code Description Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Basement-mechanical room equipment shall be provided in accordance with Section Comments:Relocated laundry appliance obstructing clear path of 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or access to electric panel.Maintain clear,unobstructed path to utilities less,and Section 110.33 of NFPA 70 for electrical equipment at all times. rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). ; iI lfbf • , ....16 : to? Iii. ili .. ,.:, A , ., , _ _17 , j . --.1...fiad".*. 'V... I-'I/ 1 fi'l',. 0 . • ' . Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Basement-Mechanical Room with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide permanent signage on door indicating ROOM"or similar approved wording.The disconnecting "ELECTRICAL PANEL INSDE"or other approved wording.Laminated means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably paper will not be accepted. marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. GENERATED ON 9/17/26, 12:40 PM 8 OF 11 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Couch near front desk for permanent wiring and shall be listed and labeled in Comments:Remove mini fridge plugged to extension cord.Appliance accordance with UL 817.Extension cords and flexible shall plug directly to outlet. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Stairs from main exit for permanent wiring and shall be listed and labeled in Comments:Remove extension cord. accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. 4" i a • Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Stairs from main exit for permanent wiring and shall be listed and labeled in Comments:Remove power strip next to stairs plugged to extension accordance with UL 817.Extension cords and flexible cord,power strip shall plug directly to a wall outlet.Currently power cordsshall not be affixed to structures,extended through strip is also hanging by wires. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 0/17/28, 12:40 PM 9 OF 11 Portable Fire Extingusihers Stat.n; Cod, Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,Installed and Comments:Annually serviced 2A-10BC fire extinguisher shall be maintained in accordance with this section and NFPA 10. properly located in upper and lower level of massage business.Last Exceptions:1.The distance of travel to reach an extinguisher recorded service in April 2025. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 9/17/26, 12:40 PM 10 OF 11 '® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/17/28, 12:40 PM 11 OF 11