Loading...
HomeMy WebLinkAboutNEIGHBORHOOD MART-2100-2102 LAFAYETTE ST OF W A . INVOICE DATE DUE DATE` INVOICE# TOTAL DUE 4 11( 09/17/2026 10/22/2026 2027-00000136 $80.00 U /�I►; 0 • •II lllltli II I • > T-=T 0 A 4S 7vilN Customer#: 13067 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable NEIGHBORHOOD MART 715 Mulberry St 2100 LAFAYETTE ST WATERLOO, IA 50703 WATERLOO,IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-2100-2102 LAFAYETTE ST- FOR BILLING INQUIRY: (319)291-4323 09/11/26 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 13067 09/17/2026 10/22/2026 2027-00000136 $80.00 Less Prepayment $0.00 Total Due —> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue 4* Inspection Report 425 E.3rd Street N- ,;* Neighborhood Mart-2100-2102 Lafayette AVE,BLDG 2100-2102 Lafayette Ave, Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0911112026 Annual Inspection(1Yr) i c. '7- 20540 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION 0 40 0 15 ® 29 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 10/0712026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09111/2026 @ 13:14 •$80 annual inspection fee BRAD BALDWIN-0911112026 @ 13:14 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-0911112026 @ 13:14 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-0911112026 @ 13:15 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-0911112026 @ 13:15 Kitchen hood cleaning and suppression system inspections due on 9130126.Contractors reports shall be uploaded to Compliance Engine including deficiencies corrected. BRAD BALDWIN-09111/2026 @ 13:16 Fire extinguishers due annually serviced in September 2026 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection 1 OF 10 GENERATED ON 9/15/26, 8:16 AM Muhammad"John"Sarwar Date: BRAD BALDWIN 0911512028 CHECKLISTS GENERATED ON 9/15/28, 8:18 AN 2 OF 10 Additional Codes Status Code Description Fail 1010.2.4-Locks and latches. Locks and latches shall be permitted to prevent operation of Location:Front exit door doors where any of the following exist:1.Places of detention Comments:Provide permanent approved signage indicating'THIS or restraint.2.In Group 1-1,Condition 2 and Group 1-2 DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS"or other occupancies where the clinical needs of persons receiving approved wording on interior of door.Paper or laminated paper will care require containment or where persons receiving care not be accepted. pose a security threat,provided that all clinical staff can readily unlock doors at all times,and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups B,F,M and S, and in places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3.3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.8.Other than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key- operated locking device.8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9.Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space. 3 OF 10 GENERATED ON 9/15/2t, 8:16 AN Fail 102.4•Application of building code. The design and construction of new structures shall comply Location:Back storage area with the International Building Code,and any alterations, Comments:Licensed plumbing contractor shall obtain permit and additions,changes In use or changes in structures required inspection for water heater installed without permit.Manufacture date by this code,which are within the scope of the International of Oct.2025 Building Code,shall be made in accordance therewith. if 0‘.\\,,._ ____ -, . ,,-.0.- r t r / t rt''' 11n Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Kitchen with the International Building Code,and any alterations, Comments:Licensed plumbing contractor shall obtain permit and additions,changes in use or changes in structures required by this code,which are within the scope of the International inspection for water heater(50 Gallon)installed without permit. Building Code,shall be made in accordance therewith. Manufacture date of July 2025 Fail 1020.3-Width and capacity. The required capacity of corridors shall be determined as Location:Back office specified in Section 1005.1,but the minimum width shall be Comments:A clear unobstructed(24 inches in width minimum)path not less than that specified in Table 1020.3.Exception:In Group 1-2 occupancies,corridors are not required to have a to electric panels shall be maintained. clear width of 96 inches(2438 mm)in areas where there will not be stretcher or bed movement for access to care or as part of the defend-in-place strategy. GENERATED ON 9/15/28, 8:18 AM 4 OF 10 Fail 6303,5.3-Securing compressed gas containers,cylinders is Location:Kitchen ; and tanks. Compressed gas containers,cylinders and tanks shall be Comments:Secure all compressed gas cylinders with chain to avoid secured to prevent falling caused by contact,vibration or tip over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Fail 603.1.1-Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, Location:Kitchen-Black&Decker"toaster" wiring,devices and appliances shall be tested;and listed by Comments:Verify appliance is commercially listed.If approved, an approved agency and labeled;and installed,used and appliances including heat producing elements or motors shall plug maintained in accordance with NFPA 70 and all instructions directly to a permanent outlet.Remove appliance from building if included as part of such listing. found to be listed for"residential use only" Fail 603.1.1-Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, Location:Kitchen-Fryer wiring,devices and appliances shall be tested;and listed by Comments:Residential listed deep fryer shall be removed from use an approved agency and labeled;and installed,used and in kitchen.Equipment shall be used per its approved listing. maintained in accordance with NFPA 70 and all instructions included as part of such listing. GENERATED ON 9/15/26, 8:16 AM 5 OF 10 Electrical Safety - =`, Cone Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Lunchables cooler Identified electrical hazards shall be abated.Identified Comments:Provide listed cord protector to avoid possible damage to hazardous electrical conditions in permanent wiring shall be cord over walkway. brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. a r- a, ..r w..: ft ii. ./ rhWgRNi�"Z 0. fc0ntai Produc ns t Nic ��c 'tla'ct;,e 0he erne. ,,,,k,, it ----:.„! • -' -- N. iiiiiiv i m:.,�t A o, . . ,,,,,„..,,,,,, GENERATED ON 9/15/28, 8:16 AM 6 OF 10 Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Exterior neon lighting Identified electrical hazards shall he abated.Identified Comments:Exposed neon lighting shall be properly disconnected or hazardous electrical conditions in permanent wiring shall be repaired brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Back office-ceiling prohibited.Approved covers shall be provided for all switch Comments:Electrical connections shall be properly capped and box and electrical outlet boxes. cover installed. "' ' / OF 10 GENERATE.) ON 9/15/2G, £S:IC AM Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open Junction boxes and open-wiring splices shall be Location:Front of building•Exterior prohibited.Approved covers shall be provided for all switch Comments:Licensed electrical contractor shall properly cap wires in and electrical outlet boxes. box with cover.Obtain copy of Invoice from contractor to provide for inspector. • • Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Back office equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or Comments:Remove storage within 36 inches of electric panels. less,and Section 110.33 of NFPA 70 for electrical equipment Maintain proper clearances at all times. rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Fail 603.4.1-Labeling. E) Doors into electrical control panel rooms shall be marked Location:Back office-door with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide permanent approved signage on door indicating ROOM"or similar approved wording.The disconnecting "ELECTRIC ROOM"or other approved wording.Laminated paper will means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably not be accepted. marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. GENERATED ON 8/15/28,8:18 AN e OF 10 Fail 603.5• Relocatable power taps and current taps.Multiplug Oadapters. Location: Kitchen Multiplug adapters, such as cube adapters, unfused plug Comments: Multi-plug adapters (see photo attached) are prohibited. strips or any other device not complying with NFPA 70 shall Approved to replace with properly mounted power strip with manual be prohibited. The construction and use of current taps and reset for low wattage electronics only. Appliances with heating relocatable taps shall be in accordance with NFPA 70 and this elements or motors shall plug directly to wall outlet code. 4.6 44141110404, Cif I 3 e .r wi3 a" ; ruur ® t. ,i Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute Location: Behind register counter - Above "Jack Daniels" shelving for permanent wiring and shall be listed and labeled in Comments: Black flexible supply cord extending above ceiling shall accordance with UL 817. Extension cords and flexible be removed from above ceiling. Flexible supply cords shall not pass cordsshall not be affixed to structures, extended through through concealed spaces. walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 9 OF 10 GENERATED ON 9/1.5/20, 6:10 AM Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/15/26, 8:16 AN 10 OF 10