Loading...
HomeMy WebLinkAboutTHE SLIPPERY PICKLE-341 FLETCHER AVE OF W A . INVOICE DATE DUE DATE INVOICE# TOTAL DUE ,� t® 09/17/2026 10/22/2026 2027-00000141 $80.00 . , : / O • •II IIU II • > ' O °S 1 v 11�� Customer#: 24571 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable THE SLIPPERY PICKLE 715 Mulberry St 341 FLETCHER AVE WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-341 FLETCHER AVE-09/15/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24571 09/17/2026 10/22/2026 2027-00000141 $80.00 Less Prepayment $0.00 Total Due—* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. �•,G�,G Waterloo Fire Rescue t N.4 Inspection Report 425 E.3rd Street """• The Slippery Pickle-341 Fletcher AVE,BLDG 341 Fletcher Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 09115/2026 Annual Inspection(1Yr) a(1. -J 19406 Lead Inspector Shift Station Unit BRAD BALDWIN N/A N/A NIA Other Inspectors N/A SUMMARY OF INSPECTION ® 41 08 027 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 1010712026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09/16/2026 @ 08:28 •$80 annual inspection fee BRAD BALDWIN-0911612026 @ 08:28 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-09116/2026 @ 08:28 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-0911612026 @ 08:28 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completedeelpost stinspection Karla Date:_ BRAD BALDWIN 09/1612026 CHECKLISTS GENERATED ON 9/16/26, 6:31 AM 1 OF 6 Emergency Equipment Status Code Description Fail 1203.2.15-Means of egress Illumination, Emergency power shall be provided for means of egress Location:Back exit near bar illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light on exit sign that failed to illuminate.Breaker to exit sign was found off during inspection GENERATED ON 9/16/28, 8:31 AM 2 OF 6 Electrical Safety Status Code Description Fall 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Small electric panel near walk-In freezer equipment shall be provided In accordance with Section Comments:Remove storage within 36"of panel and maintain clear 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or path of access for fire fighters less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Billiards tables(3) for permanent wiring and shall be listed and labeled in Comments:Extension cords plugged to lights above tables shall be accordance with UL 817.Extension cords and flexible removed.Would approve to replace with properly supported power cordsshall not be affixed to structures,extended through strip with manual reset for low wattage electronics only.Power strip walls,ceilings or floors,or under doors or floor coverings, shall plug directly to a permanent outlet. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Kitchen-POS system for permanent wiring and shall be listed and labeled in Comments:Remove power strip plugged to extension cord that accordance with UL 817.Extension cords and flexible extends above drop ceiling.Flexible supply cords shall not extend cordsshall not be affixed to structures,extended through through concealed spaces and power strips shall plug directly to a walls,ceilings or floors,or under doors or floor coverings, permanent outlet. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Security camera room for permanent wiring and shall be listed and labeled in Comments:Remove multiple extension cords to cameras.Would accordance with UL 817.Extension cords and flexible approve to replace with properly supported power strip with manual cordsshall not be affixed to structures,extended through reset for low wattage electronics only.Power strip shall plug directly walls,ceilings or floors,or under doors or floor coverings, to a permanent outlet. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 9/16/26, 8:31. AP 3 OF 6 Fail 603.6•Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Walk-in cooler-behind bar for permanent wiring and shall be listed and labeled in Comments:Flexible supply cord extending through wall of cooler accordance with UL 817.Extension cords and flexible shall be removed from through wall.Also,all wiring connections cordsshall not be affixed to structures,extended through shall be made properly per NFPA 70.Owner stated that blower in walls,ceilings or floors,or under doors or floor coverings, cooler is not functional and will be removed, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. r ,l fFt1 i4+ li, 1 , , /, , . Commercial Cooking Hood Suppression System Status Code Description Fail 606.3.3.1-Inspection. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust appurtenances shall be inspected at intervals specified in Comments:Contractor(AKA Hood Cleaning)indicated a hinge kit Table 606.3.3.1 or as approved by the fire code official. needs installed for access on roof.Owners stated,Beals Sheet Metal Inspections shall be completed by qualified individuals. has installed hinge kit,AKA Hood Cleaning scheduled for visit prior to re-inspection and shall clear deficiency if repaired. GENERATED ON R/16/24, 8:37. AM 4 OF 6 Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Entire building maintained in accordance with this section and NFPA 10. Comments:Provide annual service to all extinguishers,currently due Exceptions:i.The distance of travel to reach an extinguisher for service this month of September 2026. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. 5 OF 6 GENERATED ON 9/16/26, 9:31 AM '® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/18/28, 8:31 AM 6 OF 6