HomeMy WebLinkAboutTHE SLIPPERY PICKLE-341 FLETCHER AVE OF W A . INVOICE DATE DUE DATE INVOICE# TOTAL DUE
,� t® 09/17/2026 10/22/2026 2027-00000141 $80.00 .
, : / O
• •II IIU II •
> ' O
°S 1 v 11��
Customer#: 24571 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
THE SLIPPERY PICKLE 715 Mulberry St
341 FLETCHER AVE WATERLOO, IA 50703
WATERLOO,IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION-341 FLETCHER AVE-09/15/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24571 09/17/2026 10/22/2026 2027-00000141 $80.00
Less Prepayment $0.00
Total Due—* $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
�•,G�,G Waterloo Fire Rescue
t N.4 Inspection Report 425 E.3rd Street
"""• The Slippery Pickle-341 Fletcher AVE,BLDG 341 Fletcher Ave,Waterloo IA 50701
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
09115/2026 Annual Inspection(1Yr) a(1. -J 19406
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A N/A NIA
Other Inspectors
N/A
SUMMARY OF INSPECTION
® 41 08 027
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN 1010712026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-09/16/2026 @ 08:28
•$80 annual inspection fee
BRAD BALDWIN-0911612026 @ 08:28
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224
BRAD BALDWIN-09116/2026 @ 08:28
•Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-0911612026 @ 08:28
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completedeelpost stinspection
Karla Date:_ BRAD BALDWIN 09/1612026
CHECKLISTS
GENERATED ON 9/16/26, 6:31 AM 1 OF 6
Emergency Equipment
Status Code Description
Fail 1203.2.15-Means of egress Illumination,
Emergency power shall be provided for means of egress Location:Back exit near bar
illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light on exit sign that failed to
illuminate.Breaker to exit sign was found off during inspection
GENERATED ON 9/16/28, 8:31 AM 2 OF 6
Electrical Safety
Status Code Description
Fall 603.4-Working space and clearancesclearance.
A working space of not Working space around electrical Location:Small electric panel near walk-In freezer
equipment shall be provided In accordance with Section Comments:Remove storage within 36"of panel and maintain clear
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or path of access for fire fighters
less,and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts.The minimum required working space
shall be not less than 30 inches(762 mm)in width,36 inches
(914 mm)in depth and 78 inches(1981 mm)in height shall be
providedin front of electrical service equipment.Where the
electrical service equipment is wider than 30 inches(762
mm),the minimum working space shall be not less than the
width of the equipment.Storage of materials shall not be
located within the designated working space.Exceptions:1.
Where other dimensions are required or allowed by NFPA 70.
2.Access openings into attics or under-floor areas that
provide a minimum clear opening of 22 inches(559 mm)by 30
inches(762 mm).
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Billiards tables(3)
for permanent wiring and shall be listed and labeled in Comments:Extension cords plugged to lights above tables shall be
accordance with UL 817.Extension cords and flexible removed.Would approve to replace with properly supported power
cordsshall not be affixed to structures,extended through strip with manual reset for low wattage electronics only.Power strip
walls,ceilings or floors,or under doors or floor coverings, shall plug directly to a permanent outlet.
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Kitchen-POS system
for permanent wiring and shall be listed and labeled in Comments:Remove power strip plugged to extension cord that
accordance with UL 817.Extension cords and flexible extends above drop ceiling.Flexible supply cords shall not extend
cordsshall not be affixed to structures,extended through through concealed spaces and power strips shall plug directly to a
walls,ceilings or floors,or under doors or floor coverings, permanent outlet.
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Security camera room
for permanent wiring and shall be listed and labeled in Comments:Remove multiple extension cords to cameras.Would
accordance with UL 817.Extension cords and flexible approve to replace with properly supported power strip with manual
cordsshall not be affixed to structures,extended through reset for low wattage electronics only.Power strip shall plug directly
walls,ceilings or floors,or under doors or floor coverings, to a permanent outlet.
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
GENERATED ON 9/16/26, 8:31. AP 3 OF 6
Fail 603.6•Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Walk-in cooler-behind bar
for permanent wiring and shall be listed and labeled in Comments:Flexible supply cord extending through wall of cooler
accordance with UL 817.Extension cords and flexible shall be removed from through wall.Also,all wiring connections
cordsshall not be affixed to structures,extended through shall be made properly per NFPA 70.Owner stated that blower in
walls,ceilings or floors,or under doors or floor coverings, cooler is not functional and will be removed,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
r
,l fFt1 i4+
li, 1 , ,
/, ,
.
Commercial Cooking Hood Suppression System
Status Code Description
Fail 606.3.3.1-Inspection.
Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust
appurtenances shall be inspected at intervals specified in Comments:Contractor(AKA Hood Cleaning)indicated a hinge kit
Table 606.3.3.1 or as approved by the fire code official. needs installed for access on roof.Owners stated,Beals Sheet Metal
Inspections shall be completed by qualified individuals. has installed hinge kit,AKA Hood Cleaning scheduled for visit prior
to re-inspection and shall clear deficiency if repaired.
GENERATED ON R/16/24, 8:37. AM 4 OF 6
Portable Fire Extingusihers
Status Code Description
Fail 906.2-General requirements.
Portable fire extinguishers shall be selected,installed and Location:Entire building
maintained in accordance with this section and NFPA 10. Comments:Provide annual service to all extinguishers,currently due
Exceptions:i.The distance of travel to reach an extinguisher for service this month of September 2026.
shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device,provided that all of the
following conditions are met:2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal.2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10.3.In Group 1-3,portable fire
extinguishers shall be permitted to be located at staff
locations.
5 OF 6
GENERATED ON 9/16/26, 9:31 AM
'® Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $80.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 9/18/28, 8:31 AM 6 OF 6