Loading...
HomeMy WebLinkAboutWALMART-1334 FLAMMANG DR 0F W 4 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE eo 09/17/2026 10/22/2026 2027-00000142 $100.00 • •11 1 111/11 11 II • *- ' 41. 3S 7vtl‘' Customer#: 4747 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WALMART 715 Mulberry St 1334 FLAMMANG DR WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1334 FLAMMANG DR-09/17/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4747 09/17/2026 10/22/2026 2027-00000142 $100.00 Less Prepayment $0.00 Total Due-> $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. *,y Waterloo Fire Rescue •` Inspection Report 425 E.3rd Street � Walmart#1496-1334 Flammang DR,BLDG 1334 Flammang Dr,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0911712026 Annual Inspection(1Yr) REINSPECTION) 7l� R 18028-R2 Lead Inspector Shift 11! Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION D O 0 3 0 7 Passed codes Resolved violations Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 10/08/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0911712026 @ 13:59 S100 re-inspection fee for failure to complete corrections on 9117/26 inspection.Complete corrections to avoid fees at following inspections. BRAD BALDWIN-0812712026 @ 10:52 •$610 annual inspection fee BRAD BALDWIN-08127/2026 @ 10:52 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-08/27/2026 @ 10:52 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-08127/2026 @ 10:52 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-08127/2026 @ 10:52 Kitchen hood cleaning due 1016/26. BRAD BALDWIN-08127/2026 @ 10:52 Commercial remodel permit obtained but work has yet to start due to legal issues.All required inspections shall be obtained as work is completed if project does continue. BRAD BALDWIN-0812712026 @ 10:52 Fire drop door test-2026 GENERATED ON 9/17/26, 2:01 PM 1 OF 5 fi .55 100 n yl • .ir. lu1(,c, GN$ BRAD BALDWIN-08/27/2026 @ 10:52 8/27126 re-inspection scheduled for 9am,inspector shall be contacted if need to re-schedule. BRAD BALDWIN-08127/2026 @ 10:52 Egress lighting and exit sign testing BRAD BALDWIN-08/27/2026 @ 10:52 Withholding re-inspection fee on 8/27126 due to progress,complete corrections to avoid fees at following inspections.Next re-inspection scheduled for 9/17126 at 9am with Kevin. SIGNATURES Contact signature Inspector signature No signature Report completededpost stinspection Ryan Rand(2025) Date: BRAD BALDWIN 09/17/2026 CHECKLISTS GENERATED ON 0/17/20, 2:01 PM 2 OF 5 Reinspection `t tus Coo, Description Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Human resource TV monitor for permanent wiring and shall be listed and labeled in Comments:Monitor supply cord shall not pass through wall.Adding accordance with UL 817,Extension cords and flexible a new outlet to complete repair requires a licensed electrical cordsshall not be affixed to structures,extended through contractor to obtain a permit and inspection. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or Additional comments:Permit obtained by(Davenport Electric physical impact.Extension cords shall be used only with Contract Company).Contractor is required to request inspection. portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Theft detection office for permanent wiring and shall be listed and labeled in Comments:Mobile AC unit plugged to extension cord shall plug accordance with UL 817.Extension cords and flexible directly to a permanent outlet,currently plugged to extension cord cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, Additional comments:Permit obtained by(Davenport Electric nor shall such cords be subject to environmental damage or Contract Company).Contractor is required to request inspection. physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 606.3.3.1-Inspection. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood suppression system appurtenances shall be inspected at intervals specified in Comments:Provide required bi-annual inspection and report to be Table 606.3.3.1 or as approved by the fire code official. uploaded to Compliance Engine including all deficiencies corrected. Inspections shall be completed by qualified individuals. Past due since 3125126.Inspection by Averus INC in March 2026 rejected due to lack of proper license with the State Of Iowa. Additional comments:No progress on 9/17/26 Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Grocery back room materials and systems used to protect joints and voids in the Comments:Carefully remove paint from fire rating tags without following locations shall be maintained.The materials and altering or removing tag information on double doors. systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERATED ON 9/17/28, 2:01 PM 3 OF 5 Fall 903.3.3•Obstructed locations. Automatic sprinklers shall be Installed with regard to Location:Customer service•Above"CoinStar"machine obstructions that will delay activation or obstruct the water Comments:Remove dustltlebris from sprinkler heads(2) distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that Is being Additional comments:No progress on 9/17126 used.Automatic sprinklers shall be Installed In or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)In width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system In accordance with Section 904. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Above and near west"self-checkout"area. obstructions that will delay activation or obstruct the water Comments:Remove dustltlebris from several dirty sprinkler heads distribution pattern and shall be in accordance with the noted. applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under Additional comments:No progress on 9/17/26 covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fail 903.3.3-Obstructed locations. CAutomatic sprinklers shall be installed with regard to Location:Cart coral in west vestibule-Near hanging heater obstructions that will delay activation or obstruct the water Comments:Remove dust/debris from sprinkler head distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being Additional comments:No progress on 9/17126 used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. GENERATED ON e/17/20, 2:01 PM 4 OF 5 • Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA N/A NIA GENERATED ON 9/17/28, 2:01 PM 5 OF 5 '® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $610.00 Invoice Number Check Number Transaction Number NIA NIA NIA 6 OF 6 GENERATED ON 9/18/26, 8:38 AM Fail 704.1-Maintaining protection. OWhere required when the building was originally constructed, Location:Room 0300 materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floorlceiling assemblies and roof or rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer&1/039;s installation instructions. Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:Tunnel-door by hallway stairs and latch automatically. Comments:Repair or replace fire rated door that fails to self shut and latch.Also,remove device holding door open. GENERATED ON 0/18/26, 8:38 AM 5 OF fi Fire Resistant Construction Maintenance Status Code Description Fail 704.1 - Maintaining protection. 0 Where required when the building was originally constructed, Location: Athletic foyer materials and systems used to protect joints and voids in the Comments: Replace missing ceiling tile. following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls, floors or floor/ceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1 - Maintaining protection. 0 Where required when the building was originally constructed, Location: Room # 205 materials and systems used to protect joints and voids in the Comments: Replace missing ceiling tile following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls, floors or floorlceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 4 OF 6 GENERATED ON 9/18/26, 8:30 AM Documentation Stator- Cod(= Description Fail 403.4.1-First emergency evacuation drill. The first emergency evacuation drill of each school year shall Location:Fire drill be conducted within 10 days of the beginning of classes. Comments:Provide documentation of date of first Fire Drill,email to inspector. Fire Service Features Star"s Code Description Fail 506.2-Key box maintenance. The operator of the building shall immediately notify the fire Location:Room#342B code official and provide the new key where a lock is changed Comments:Contact Waterloo Fire Department at 319-291-4460 to or rekeyed.The key to such lock shall be secured in the key provide copy of key in Knox Box. box. Electrical Safety Status Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Basement-Wrestling Room Identified electrical hazards shall be abated.Identified Comments:Outlet and conduit not anchored to wall shall be repaired. hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.5.2-Application and usePower supply. ORelocatable power taps and current taps shall be directly Location:Christine Erie's desk connected to a permanently installed receptacle.Exceptions: 1.Where approved for use in a Group A occupancy or in a Comments:Remove power strips daisy chained(plugged from one to another).Each power strip shall plug directly to a permanent outlet. meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Fail 603.5.2-Application and usePower supply. Ox Relocatable power taps and current taps shall be directly Location:Joanie Spencers desk connected to a permanently installed receptacle.Exceptions: 1.Where approved for use in a Group A occupancy or in a Comments:Remove power strips daisy chained(plugged from one to another).Each power strip shall plug directly to a permanent outlet. meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. GENERATED ON 9/18/26, 8:30 AM 3 OF 6 CHECKLISTS Means of Egress Status Code Description Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Rooms#201 to#203 continuously maintained free from obstructions or Comments:Remove obstruction(storage)not allowing door to fully impediments to full instant use in the case of fire or other open.Also,remove filing cabinet in exit path,maintain clear path of emergency where the building area served by the means of exit at all times. egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Additional Codes Status Code Description Fail 313.1-General. OFueled equipment including,but not limited to,motorcycles, Location:Room#200 mopeds,lawn-care equipment,portable generators and Comments:Remove gas powered mower from building. portable cooking equipment,shall not be stored,operated or repaired within a building.Exceptions:1.euildings or rooms constructed for such use in accordance with the International Building Code.2.Where allowed by Section 314.3.Storage of equipment utilized for maintenance purposes is allowed in approved locations where the aggregate fuel capacity of the stored equipment does not exceed 10 gallons(38 L)and the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Room#130 code or the International Building Code shall be installed, Comments:Remove microwave and fridge plugged to multi-plug used and maintained in accordance with NFPA 70 and adapter.Appliances including heat producing elements and motors Sections 603.2 through 603.10. shall plug directly to a permanent outlet. Fail 807.1-General. The following requirements shall apply to all occupancies: Location:Stage curtains 1.Furnishings or decorative materials of an explosive or Comments:Provide documentation of fire retardant treatment applied highly flammable character shall not be used.2.Fire-retardant to curtains.Last recorded treatment in 2020.Email document to coatings in existing buildings shall be maintained so as to inspector. retain the effectiveness of the treatment under service conditions encountered in actual use.3.Furnishings or other objects shall not be placed to obstruct exits,access thereto, egress therefrom or visibility thereof.4.The permissible amount of noncombustible decorative materials shall not be limited. Emergency Equipment Status Code Description Fail 1203.2.6-Exit signs. OEmergency power shall be provided for exit signs as required Location:Athletic meeting room in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign currently hanging by wires. the required load for a duration of not less than 90 minutes. Fail 1203.4.3-Records. ORecords of the inspection,testing and maintenance of Location:Entire building emergency and standby power systems shall include the date Comments:Provide documentation of testing all exit signs and of service,name of the servicing technician,a summary of emergency egress lighting including repairs completed if needed. conditions noted and a detailed description of any conditions Email to inspector. requiring correction and what corrective action was taken. Such records shall be maintained. OF 6 GENERATED ON 9/19/26,n:30 An Waterloo Fire Rescue j Ik Inspection Report 425 E.3rd Street _,.3. West High School-425 E Ridgeway AVE,BLDG 425 E Ridgeway Ave,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 09108/2026 Biennial Inspection(2yrs) /"l0 15445 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA • N/A Other Inspectors JEREMIAH VANDYKE,BROCK WELIVER SUMMARY OF INSPECTION 0 61 (x 15 ® 5 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 10/09/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09/08/2026 @ 14:41 •5610 annual inspection fee BRAD BALDWIN-09/0812026 @ 14:41 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-09108/2026 @ 14:41 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-09/0812026 @ 14:42 Kitchen hood suppression inspection and report to be uploaded to Compliance Engine with deficiencies corrected due 9/18/26 BRAD BALDWIN-09108/2026 @ 15:15 Clothes dryer vent cleanings completed on 3118/26 by Harris Cleaning. BRAD BALDWIN-09/09/2026 @ 07:39 Christmas and like lighting noted in multiple spaces throughout building approved for temporary lighting(90 days).Lighting shall be removed after 90 days of usage has expired. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Zach Kelly-Maintenance Director Date: BRAD BALDWIN 09110/2026 GENEPATED ON 9/10/26, 8:30 AM 1 OF 6 O� WA ? INVOICE DATE DUE DATE INVOICE # TOTAL DUE 4,44 „pe 09/17/2026 10/22/2026 2027-00000143 $610.00 u ,lil�l���. / Q • ' r r rr r ' rr' rr s Customer #: 3597 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WEST HIGH SCHOOL 715 Mulberry St 425 E RIDGEWAY AV WA TERL 00, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 425 E RIDGEWAY AVE- FOR BILLING INQUIRY: (319)291-4323 09/08/26 Description Total Price INSPECTION 100,000 $600.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 3597 _ 09/17/2026 10/22/2026 2027-00000143 $610.00 Less Prepayment $0.00 Total Due $610.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.