Loading...
HomeMy WebLinkAboutWEST HIGH SCHOOL-425 E RIDGEWAY AVE 0F W A pF INVOICE DATE DUE DATE INVOICE# TOTAL DUE ''0 09/17/2026 10/22/2026 2027-00000143 $610.00 U ,ii4�l.•. I* O • • I I II III II•III • Customer#: 3597 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WEST HIGH SCHOOL 715 Mulberry St 425 E RIDGEWAY AV WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-425 E RIDGEWAY AVE- FOR BILLING INQUIRY: (319)291-4323 09/08/26 Description Total Price INSPECTION 100,000 $600.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 3597 09/17/2026 10/22/2026 2027-00000143 $610.00 Less Prepayment $0.00 Total Due—> $610.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue •,•�s Inspection Report 425 E.3rd Street ,.a 3, West High School-425 E Ridgeway AVE,BLDG 425 E Ridgeway Ave,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 09/08/2026 Biennial Inspection(2yrs) ' 7— 43(e/0 15445 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors JEREMIAH VANDYKE,BROCK WELIVER SUMMARY OF INSPECTION 0 61 U 15 ® 5 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN brad.baldwin@waterloo-ia.org,3192914319 10/09/2026 GENERAL NOTES BRAD BALDWIN-09108/2026 @ 14:41 •$610 annual inspection fee BRAD BALDWIN-09/08/2026 @ 14:41 •Commercial Fire Inspector—brad.baldwin@waterloo-ia.org—Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-0910812026 @ 14:41 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday—Friday,9:00 a.m.—4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-09/08/2026 @ 14:42 Kitchen hood suppression inspection and report to be uploaded to Compliance Engine with deficiencies corrected due 9/18/26 BRAD BALDWIN-09108/2026 @ 15:15 Clothes dryer vent cleanings completed on 3/18126 by Harris Cleaning. BRAD BALDWIN-09/09/2026 @ 07:39 Christmas and like lighting noted in multiple spaces throughout building approved for temporary lighting(90 days).Lighting shall be removed after 90 days of usage has expired. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Zach Kelly-Maintenance Director Date: BRAD BALDWIN 09/10/2026 GENERATED ON 9/10/26, 8:30 AM 1 OF 6 CHECKLISTS Means of Egress Status Code Description Fail 1032.2-Reliability. ORequired exit accesses,exits and exit discharges shall be Location:Rooms 0201 to 0203 continuously maintained free from obstructions or Comments:Remove obstruction(storage)not allowing door to fully impediments to full instant use in the case of lire or other open.Also,remove filing cabinet in exit path,maintain clear path of emergency where the building area served by the means of exit at all times. egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Additional Codes Status Code Description Fail 313.1-General. OFueled equipment including,but not limited to,motorcycles, Location:Room 0200 mopeds,lawn-care equipment,portable generators and Comments:Remove gas powered mower from building. portable cooking equipment,shall not be stored,operated or repaired within a building.Exceptions:(Buildings or rooms constructed for such use in accordance with the International Building Code.2.Where allowed by Section 314.3.Storage of equipment utilized for maintenance purposes is allowed in approved locations where the aggregate fuel capacity of the stored equipment does not exceed 10 gallons(38 L)and the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Room 4130 code or the International Building Code shall be installed, Comments:Remove microwave and fridge plugged to multi-plug used and maintained in accordance with NFPA 70 and adapter.Appliances including heat producing elements and motors Sections 603.2 through 603.10. shall plug directly to a permanent outlet. Fail 807.1-General. The following requirements shall apply to all occupancies: Location:Stage curtains (Furnishings or decorative materials of an explosive or Comments:Provide documentation of fire retardant treatment applied highly flammable character shall not be used.2.Fire-retardant to curtains.Last recorded treatment in 2020.Email document to coatings in existing buildings shall be maintained so as to inspector. retain the effectiveness of the treatment under service conditions encountered in actual use.3.Furnishings or other objects shall not be placed to obstruct exits,access thereto, egress therefrom or visibility thereof.4.The permissible amount of noncombustible decorative materials shall not be limited. Emergency Equipment Status Code Description Fail 1203.2.6-Exit signs. OEmergency power shall be provided for exit signs as required Location:Athletic meeting room in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign currently hanging by wires. the required load for a duration of not less than 90 minutes. Fail 1203.4.3-Records. Records of the inspection,testing and maintenance of Location:Entire building emergency and standby power systems shall include the date Comments:Provide documentation of testing all exit signs and of service,name of the servicing technician,a summary of emergency egress lighting including repairs completed if needed. conditions noted and a detailed description of any conditions Email to inspector. requiring correction and what corrective action was taken. Such records shall be maintained. OF 6 GENERATED vu s/le/Os, 6:30 Ni Documentation Status Code Description Fail 403.4.1 - First emergency evacuation drill. OThe first emergency evacuation drill of each school year shall Location: Fire drill be conducted within 10 days of the beginning of classes. Comments: Provide documentation of date of first Fire Drill, email to inspector. Fire Service Features Status Code Description Fail 506.2 - Key box maintenance. O The operator of the building shall immediately notify the fire Location: Room #342B code official and provide the new key where a lock is changed Comments: Contact Waterloo Fire Department at 319-291-4460 to or rekeyed. The key to such lock shall be secured in the key provide copy of key in Knox Box. box. Electrical Safety Status Code Description Fail 603.2 -Abatement of unsafe conditions and electrical 0 hazards. Location: Basement - Wrestling Room Identified electrical hazards shall be abated. Identified Comments: Outlet and conduit not anchored to wall shall be repaired. hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.5.2 -Application and usePower supply. ORelocatable power taps and current taps shall be directly Location: Christine Erie's desk connected to a permanently installed receptacle. Exceptions: Comments: Remove power strips daisychained (plugged p (p gged from one to 1. Where approved for use in a Group A occupancy or in a another). Each power strip shall plug directly to a permanent outlet. meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Fail 603.5.2 -Application and usePower supply. 0 Relocatable power taps and current taps shall be directly Location: Joanie Spencer's desk connected to a permanently installed receptacle. Exceptions: Comments: Remove power strips daisy chained (plugged from one to 1. Where approved for use in a Group A occupancy or in a another). Each power strip shall plug directly to a permanent outlet. meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. GENERATED ON 9/10/26, 8:30 AM 3 OF 6 Fire Resistant Construction Maintenance 5 d;u_, Sc k Description Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Athletic foyer materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Room#205 materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERATED ON 9/18/26, 8:30 AM 4 OF 6 Fad 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Room#300 materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floorlceiling assemblies and roof or rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.S.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 705.2.4-Door operation. xl Swinging fire doors shall close from the full-open position Location:Tunnel-door by hallway stairs and latch automatically. Comments:Repair or replace fire rated door that fails to self shut and latch.Also,remove device holding door open. GENERATED ON 9/18/26, 8:30 AM 5 OF 6 Flo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $610.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/18/26, 8:38 AM 6 OF 6