HomeMy WebLinkAboutscan-2GENERAL NOTES A. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER THESE STANDARD STRUCTURAL NOTES. TYPICAL DETAILS SHALL BE USED WHENEVER APPLICABLE. B. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING WORK; AND THE ENGINEER SHALL BE IMMEDIATELY NOTIFIED, IN WRITING, OF ANY DISCREPANCIES. C. IN NO CASE SHALL DIMENSIONS BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THE STRUCTURAL DRAWINGS. D. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF UTILITY SERVICES IN THE AREA TO BE EXCAVATED BEFORE BEGINNING EXCAVATION. E. NO PIPES, DUCTS, SLEEVES, CHASES, ETC., SHALL BE PLACED IN SLABS OR WALLS, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC. F. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL TEMPORARY SHORING AND BRACING OF EXISTING STRUCTURAL ELEMENTS DURING CONSTRUCTION. ALL SHORING SHALL BE ADEQUATE TO SUPPORT ALL STRUCTURAL LOADS DURING THE REMOVAL OF THE EXISTING STRUCTURE. TEMPORARY SHORING MUST REMAIN IN PLACE UNTIL ALL NEW STRUCTURAL ELEMENTS ARE SECURED INTO PLACE PER CONSTRUCTION DOCUMENTS. G. REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR REQUIREMENTS, DIMENSIONS AND EXACT LOCATIONS OF FLOOR DRAINS, TRENCHES, DRAIN TILE, PUMPS AND EQUIPMENT INCLUDING ANCHORING SYSTEMS AND HOUSEKEEPING PADS. GENERAL CONTRACTOR TO COORDINATE ALL OF THESE ITEMS WITH ALL DISCIPLINES INVOLVED, H. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE FOLLOWING CODES AND MANUALS (LATEST ADOPTED EDITION): 1. STATE BUILDING CODE, WHEN APPLICABLE. 2. INTERNATIONAL BUILDING CODE (IBC). 3. AMERICAN CONCRETE INSTITUTE (ACI). 4. CONCRETE REINFORCING STEEL INSTITUTE (CRSI) MANUAL OF STANDARD PRACTICE (FOR PLACING AND DETAILING OF ALL REINFORCING). 5. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). 6. AMERICAN WELDING SOCIETY (AWS) STANDARDS FOR WELDING AS MODIFIED BY AISC SPECIFICATION. 7. MASONRY STANDARDS JOINT COMMITTEE (MSJC) 8. AMERICAN FOREST & PAPER ASSOCIATION NATIONAL DESIGN SPECIFICATION (AF & PA NDS) DESIGN LOADS CRITERIA A. CODES USED: 1. 2015 INTERNATIONAL BUILDING CODE 2. 2010 AMERICAN SOCIETY OF CIVIL ENGINEERS STANDARD 7 (ASCE 7-10) B. RISK CATEGORY: II C. WIND LOAD CRITERIA: 1. ULTIMATE WIND SPEED. V = 115 MPH (3 SECOND GUST) 2. NOMINAL WIND SPEED, V = 90 MPH (3 SECOND GUST) 3. WIND LOAD EXPOSURE: C 4. INTERNAL PRESSURE COEFFICIENT: +/- 0.18 (ENCLOSED BUILDING) 5. WIND TOPOGRAPHIC FACTOR: KzT = 1.0 6. C & C WIND WALL PRESSURE: REFER TO COMPONENT AND CLADDING WIND PRESSURE TABLE 7. WIND NET UPLIFT: 15 PSF (NOMINAL) D. SNOW LOAD CRITERIA: 1. GROUND SNOW LOAD, PG = 50 PSF 2. FLAT -ROOF SNOW LOAD (BALANCED), PF = 35 PSF 3. SNOW LOAD IMPORTANCE FACTOR, Is = 1.0 4. SLOPE FACTOR, Cs = 1.0 5. THERMAL FACTOR, CT = 1.0 6. SNOW EXPOSURE FACTOR, CE = 1.0 7. UNBALANCED SNOW LOAD: ON PLAN IF APPLICABLE E. LIVE LOADS 1. ROOF: 20 PSF 2. FLOOR: 50 PSF 3. STAIR ASSEMBLIES: 100 PSF 4. RAILING: 200 LBS AT ANY POINT OR 50 PLF, WHICHEVER PRODUCES MAXIMUM LOAD EFFECT 5. PARTITIONS: 15 PSF 6. LOBBIES AND FIRST FLOOR CORRIDORS: 100 PSF 7. BALCONIES: 75 PSF 8. RESIDENTIAL AREAS EXCEPT BALCONIES: 40 PSF F. DEAD LOADS 1. ROOF: 15 PSF 2. FRAMING: ACTUAL 3. MISCELLANEOUS CEILING: 6 PSF 4. MECHANICAL: SEE PLAN SHOP DRAWINGS A. SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL, SIGNED AND SEALED BY A PROFESSIONAL ENGINEER RESPONSIBLE FOR ITS PREPARATION, WHO IS REGISTERED IN THE STATE WHICH THE PROJECT IS LOCATED. B. PRIOR TO SUBMITTAL, THE CONTRACTOR SHALL REVIEW THE SHOP DRAWINGS AND MAKE ANY CORRECTIONS REQUIRED. THE CONTRACTOR SHALL STAMP AND SIGN THE SHOP DRAWINGS PRIOR TO SUBMITTAL TO THE ENGINEER. C. THE ENGINEER'S REVIEW OF SHOP DRAWINGS IS FOR GENERAL CONFORMANCE OF THE DESIGN CONCEPT. CONTRACTOR SHALL SUBMIT A SCHEDULE OF SHOP DRAWING SUBMITTALS THAT IS ACCEPTABLE TO BOTH CONTRACTOR AND ENGINEER. AFTER THE CONTRACTOR HAS REVIEWED THE SHOP DRAWINGS, PROMPT REVIEW BY THE ENGINEER WILL BE MADE OF ALL SUBMITTALS. D. FOR LARGE SUBMITTALS, REASONABLE REVIEW TIME SHALL BE ALLOWED AND MAY EXCEED TWO WEEKS, THE CONTRACTOR SHALL SUBMIT NECESSARY REQUEST FOR INFORMATION (RFI's) DURING THE DETAILING PROCESS TO AVOID SUBMITTALS THAT ARE INCOMPLETE OR NEED SIGNIFICANT VERIFICATIONS. THE CONCURRENT SUBMITTAL OF MULTIPLE SHOP DRAWINGS ("DUMPING") WILL FURTHER EXTEND THE REVIEW PROCESS AND TIME FRAME NECESSARY TO PROPERLY REVIEW EACH SUBMITTAL. E. UNLESS INDICATED OTHERWISE, THE GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF THE FOLLOWING ITEMS FOR STRUCTURAL REVIEW. REFER TO SPECIFIC SECTION OF STRUCTURAL NOTES FOR ANY ADDITIONAL CRITERIA: 1. CONCRETE MIX DESIGNS 2. PRESTRESSED CONCRETE 3. STRUCTURAL STEEL 4. OPEN -WEB BAR JOISTS 5. STEEL ROOF DECK 6. PRE-ENGINEERED METAL BUILDING DESIGN 7. PRE -FABRICATED WOOD TRUSSES 8. PRE-ENGINEERED POST -FRAME BUILDING 9. ADDITIONAL STRUCTURAL SHOP DRAWINGS REQUESTED IN THE SPECIFICATIONS F. A COPY OF ALL SHOP DRAWINGS SHALL BE MAINTAINED ON SITE AT ALL TIMES. G. SHOP DRAWINGS SHALL INCLUDE COMPLETE DETAIL SCHEDULES, PROCEDURES, AND DIAGRAMS FOR FABRICATION AND ASSEMBLY OF STRUCTURAL MEMBERS AND SUBMIT PRIOR TO FABRICATION. H. ERECTION PLANS ARE THE RESPONSIBILITY OF THE FABRICATOR. SPECIAL INSPECTIONS A. SPECIAL INSPECTIONS SHALL BE PROVIDED IN ACCORDANCE WITH IBC SECTION 1704 AND 1705. THE SPECIAL INSPECTOR SHALL BE EMPLOYED BY THE OWNER, SHALL BE THOROUGHLY KNOWLEDGEABLE OF IBC SPECIAL INSPECTION REQUIREMENTS AND SHALL DEMONSTRATE COMPETENCE TO THE SATISFACTION OF THE BUILDING OFFICIAL. THE CONTRACTOR SHALL CONTACT THE SPECIAL INSPECTOR DURING APPROPRIATE PHASES OF CONSTRUCTION SO THAT INSPECTIONS CAN BE MADE IN A TIMELY MANNER. THE SPECIAL INSPECTOR SHALL SUBMIT WRITTEN INSPECTION REPORTS TO THE ENGINEER OF RECORD'S OFFICE, WITHIN 3 WORKING DAYS OF EACH INSPECTION. ANY PROBLEMS SHOULD BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR. THE FOLLOWING ITEMS WILL REQUIRE SPECIAL INSPECTION: 1. STEEL a. SPECIAL INSPECTIONS ARE NOT REQUIRED FOR WORK DONE IN AN APPROVED FABRICATING SHOP. THE STEEL FABRICATOR MUST BE REGISTERED AND APPROVED BY THE BUILDING OFFICIAL TO PERFORM THE WORK WITHOUT SPECIAL INSPECTIONS. (IBC 1704.2.5.2). b. HIGH STRENGTH BOLTING: CONTINUOUS INSPECTIONS ARE REQUIRED FOR SLIP -CRITICAL CONNECTIONS. PERIODIC INSPECTIONS ARE REQUIRED FOR BEARING-TYP. CONNECTIONS. c. FIELD WELDING: CONTINUOUS INSPECTIONS ARE REQUIRED FOR COMPLETE AND PARTIAL PENETRATION GROOVE WELDS, MULTI -PASS FILLET WELDS AND SINGLE -PASS FILLET WELDS GREATER THAN 5/16". PERIODIC INSPECTIONS ARE REQUIRED FOR FLOOR AND ROOF DECK WELDS AND SINGLE -PASS FILLET WELDS SMALLER THAN OR EQUAL TO 5/16". CORRECT WELD FILLER MATERIAL SHALL BE VERIFIED IN ALL CASES. d. STEEL ERECTION: PERIODIC INSPECTIONS SHALL BE MADE TO VERIFY COMPLIANCE WITH THE DESIGN DRAWINGS. e. MATERIALS: THE STEEL MANUFACTURERS CERTIFIED MILL TEST REPORTS SHALL BE SUBMITTED TO THE SPECIAL INSPECTOR OR TO THE ENGINEER OF RECORD. 2. CONCRETE REINFORCEMENT: REINFORCING STEEL SHALL BE INSPECTED ON A PERIODIC BASIS. WELDING OF REINFORCEMENT SHALL BE CONTINUOUSLY INSPECTED. ONLY ASTM A706 REINFORCEMENT MAY BE WELDED. b. SAMPLING AND TESTING: CONTINUOUS INSPECTIONS SHALL BE PROVIDED DURING SLUMP TESTS AND WHEN DETERMINING THE TEMPERATURE OF FRESH CONCRETE AT THE TIME OF MAKING SPECIMENS FOR STRENGTH TESTS. c. CONCRETE PLACEMENT: CONTINUOUS INSPECTION REQUIRED. c. COLD AND HOT WEATHER CONCRETING: PERIODIC INSPECTION OF COMPLIANCE IS REQUIRED. 3. MASONRY - LEVEL B QUALITY ASSURANCE a. BEGINNING OF CONSTRUCTION: PERIODIC INSPECTION SHALL BE MADE OF MORTAR PROPORTIONS, CONSTRUCTION OF MORTAR JOINTS AND REINFORCEMENT LOCATION AND CONNECTORS. b. ONGOING CONSTRUCTION: PERIODIC INSPECTION SHALL BE PROVIDED TO VERIFY SIZE AND LOCATION OF STRUCTURAL ELEMENTS, SIZE AND LOCATION OF ANCHORS, SIZE AND TYPE OF REINFORCEMENT AND COMPLIANCE WITH HOT OR COLD WEATHER REQUIREMENTS. c. GROUTING: PERIODIC INSPECTION SHALL BE PROVIDED TO VERIFY THAT THE GROUT SPACE IS PROPERLY POSITIONED AND SITE PREPARED GROUT IS PROPERLY PROPORTIONED. CONTINUOUS INSPECTION IS REQUIRED OF GROUT PLACEMENT. d. TEST SPECIMENS: CONTINUOUS INSPECTION SHALL BE MADE DURING PREPARATION OF GROUT SPECIMENS, MORTAR SPECIMENS AND PRISMS. 4. SOILS a. THE SPECIAL INSPECTOR SHALL DETERMINE COMPLIANCE WITH THE SOIL REPORT FOR SITE PREPARATION, FILL PLACEMENT AND DENSITY TESTS. TESTING REQUIREMENTS 1. CONCRETE: a. SAMPLE FOR STRENGTH TESTS OF EACH CLASS OF CONCRETE PLACED EACH DAY SHALL BE TAKEN NOT LESS THAN ONCE A DAY, NOR LESS THAN ONCE FOR EACH 150 CUBIC YARDS OF CONCRETE, NOR LESS THAN ONCE FOR EACH 5,000 SQUARE FEET OF SURFACE AREA FOR SLABS OR WALLS. A MINIMUM OF FIVE STRENGTH TESTS SHOULD BE MADE FOR A GIVEN PROJECT. 2. MASONRY -UNIT STRENGTH METHOD: a. MASONRY UNITS SHALL BE SAMPLED AND TESTED ACCORDING TO ASTM C140. b. GROUT SHALL BE SAMPLED AND TESTED ACCORDING TO ASTM C1019. CONCRETE - CONCRETE SHALL BE STANDARD WEIGHT MIX UNLESS NOTED OTHERWISE AND MEET THE FOLLOWING CRI-ERIA: LOCATIONS f'c @ 28 DAYS AIR ENTRAINMENT MAX. WATER/CEMENT RATIO F__ DTIN'GS / FOUNDATIONS 3000 PSI 0.55 F_DORS ON GRADE 3500 PSI 0.55 C ='_UMNS 4000 PSI 0.55 E 1 _ERIOR SLABS ON GRADE 4500 PSI 6% ± 1.5% 0.45 E, DOSED EXTERIOR WALLS 4500 PSI B. C=MENT SHALL CONFORM TO ASTM C150, TYPE I / II. C. READY -MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C94. D. CONCRETE VcORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301 (LATEST EDITION) SPECIFICATIO'vS FOR STRUCTURAL CONCRETE FOR BUILDINGS", EXCEPT AS MODIFIED BY THESE DTES. E. ---MIXTURES MA'S BE USED WITH PRIOR APPROVAL OF THE ENGINEER. ADMIXTURES SHALL COMPLY TH ASTM C494 AND BE OF A TYPE THAT INCREASES THE WORKABILITY OF THE CONCRETE, BUT S-ALL NOT BE CONSIDERED TO REDUCE THE SPECIFIED MINIMUM CEMENT CONTENT (CALCIUM C-_ORIDE SHALL NOT BE USED). F. C DNTRACTOR SHALL SUBMIT MIX DESIGNS FOR APPROVAL 10 DAYS PRIOR TO FABRICATION AND STALLATION. ALL CONCRETE MIXES SHALL BE DESIGNED AND CERTIFIED BY A MATERIALS TESTING -DMPANY. G. =POJECTING CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC. SHALL BE FORMED WITH A 3/41, -HAMFER UNLESS DETAILED OR NOTED OTHERWISE. H. --LACE VAPOR RETARDER OR VAPOR BARRIER DIRECTLY BELOW FLOOR SLAB. I. -ONCRETE FLOOR SHALL BE CURED IN ACCORDANCE WITH ASTM C309. CONCRETE FLOOR SHALL BE PROTECTED FROM MOISTURE LOSS FOR A MINIMUM OF 14 DAYS, USING AN APPROVED SHEET .1EMBRANE IN ACCORDANCE WITH C171. J. =L OOR FLATNESS AND LEVELNESS TOLERANCES: UNLESS NOTED OTHERWISE, FLOORS SHALL CONFORM TO THE FOLLOWING SURFACE PROFILE TOLERANCES: a. FLOOR FLATNESS NUMBER (FF) SPECIFIED OVERALL VALUE = 20 • MINIMUM LOCAL VALUE = 15 b. FLOOR LEVELNESS NUMBER (FL) SPECIFIED OVERALL VALUE = 20 • MINIMUM LOCAL VALUE = 15 2 FLOOR TOLERANCE (FF AND FL) MEASUREMENTS SHALL BE TESTED IN ACCORDANCE WITH ASTM E 1155. ACTUAL OVERALL F-NUMBERS SHALL BE CALCULATED USING THE INFERIOR / SUPERIOR AREA METHOD. 3. CORRECT DEFECTIVE SLABS BY GRINDING OR REMOVING AND REPLACING DEFECTIVE WORK. RE - MEASURE CORRECTED AREAS BY THE SAME PROCESS. ANCHOR BOLTS A ALL ANCHOR RODS SHALL BE SUPPLIED AND INSTALLED BY THE CONCRETE CONTRACTOR, UNLESS NOTED OTHERWISE. B ALL ANCHOR RODS SHALL BE ASTM F1554 GRADE 36 HEX -HEAD, UNLESS NOTED OTHERWISE. NUTS SHALL BE ASTM A563 GRADE A HEAVY HEX. OVER -SIZED PLATE WASHERS SHALL BE ASTM A36. C ALL ANCHOR RODS SHALL BE SET WITH TEMPLATES. POST -INSTALLED ANCHORS SHALL BE ADHESIVE ANCHORING SYSTEM PROVIDED AND INSTALLED BY FRAMING CONTRACTOR. ADHESIVE ANCHORS SHALL BE "HILTI HIT-HY 200 ADHESIVE ANCHOR SYSTEM" OR APPROVED ALTERNATE. ANCHORS SHALL BE "HILTI HAS-E" THREADED ROD CONFORMING TO ISO 898-1 CLASS 5.8 OR SHALL BE MADE FROM ALL -THREADED ROD CONFORMING TO ASTM A572 GRADE 60, OR APPROVED ALTERNATE, UNLESS NOTED OTHERWISE. REINFORCING STEEL A. BAR REINFORCEMENT SHALL BE ASTM A615, GRADE 60. B. MINIMUM DEVE_OPMENT LENGTH OF REINFORCING BARS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE. MINIMUM LENGTH FOR STANDARD UN -COATED BARS IN NORMAL WEIGHT CONCRETE CONCRETE STRENGTH DE. ELOPMENT LENGTH (Ld) FOR STRAIGHT BARS (MIN. OF 12 INCHES) FOR 90 DEGREE HOOKED BARS, -ENSION CLASS A B COMPRESSION f'c IN PSI 3000 3500 =6AND S'�IALLER 44 Db 41 Db #7TO#11 55 Db 51 Db fTENfSIONLASS #6 57 Db 53 Db #7 TO #11 71 Db 66 Db #18, #14, & #11 AND SMALLER 30 Db 30 Db HOOK DEVELOPMENT LENGTH 22 Db 20 Db 4000 3_8 Db 47 Db 49 Db 62 Db 30 Db 19 Db 4500 36 Db 45 Db 42 Db 47 Db 44 Db Ld = DEVELOPMENT 58 Db 55 Db LENGTH 30 Db 30 Db 18 Db 5000 NOTE: Db = DIAME-ER 34 Db 0= REINFORCEMENT. 17 Db C. TYPICAL SPLICES: C_ASS B AS DEFINED IN ACI 318, UNLESS NOTED OTHERWISE D. ADJUSTMENT =-CTORS FOR STRAIGHT BARS IN TENSION 1. LIGHTWEIG-i CONCRETE = 1.3. 2. EPDXY CO,-"ED = 1.2. 3. EPDXY CO:--ED .%fITH COVER LESS THAN 3DB OR CLEAR SPACING LESS THAN 6 DB = 1.5. 4. HORIZONT-- "TOP" BARS WITH 12" OF CONCRETE CAST BELOW = 1.3 5. EPDXY CO-"ED i'ORIZONTAL "TOP" BARS WITH 12" OF CONCRETE CAST BELOW = NOT GREATER THAN 1.7. E. ADJUSTMENT =-CTORS FOR STRAIGHT HOOKS IN TENSION 1. LIGHTWEIG-T CONCRETE = 1.3. 2. EPDXY CO-"ED = 1.2. F. REINFORC{NC ;-EE_ SHALL BE PROVIDED WITH THE FOLLOWING AMOUNTS OF COVER FOR CAST -IN - PLACE CONC,- E`E NLESS NOTED OTHERWISE: Ml',1MUM CLEAR CONCRETE COVER FOR REIN=ORCING STEEL CONCRETE ON SC - (D,RECT CONTACT) 3„ SLAB ON GRADE CENTERED WALLS, STRUCTL= iL S-ABS EXPOSED TO SOIL OR WEATHER #6 TO #18 ==BAR 2" #5 AND SR,'--LER REBAR 1 1/2" WALLS, STRUCTL=,L S_ABS NOT EXPOSED TO EARTH OR WEATHER #11 AND S','ALLER REBAR 3/4" COLUMNS AND P ==.S (COVER TO STIRRUPS AND TIES) 1 1/2" G. ALL REINFORC ',G S-EEL, ANCHOR BOLTS, DOWELS, AND INSERTS SHALL BE SECURED IN POSITION WITH WIRE PC S Ti0',ERS, OR EQUAL, BEFORE PLACING CONCRETE OR GROUT. H. DOWELS BET,'. ::EN =OOTINGS AND WALLS SHALL BE THE SAME GRADE, SIZE, AND SPACING AS VERTICAL WA__ RE ',=ORCING. I. CONTRACTOR S-IA__ SUBMIT REINFORCING STEEL SHOP DRAWINGS FOR APPROVAL A MINIMUM OF 10 DAYS PRIOR -0=ABRICATION AND INSTALLATION. J. BARS TO BE V, E-DE_ SHALL BE ASTM A706, GRADE 60. WELDING OF REINFORCING BARS SHALL CONFORM TO -,VS 1.4. CONCRETE MASONRY A. FURNISH AND -DNS-RUCT MASONRY IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS AND SPECIFIC-"IC',S FOR MASONRY STRUCTURES AND COMMENTARY AS REPORTED BY MSJC (TMS 402 & 602 AC 530 & 530.1 / ASCE 5 & 6). MASONRY MATERIAL STRENGTHS LOCaTI: %S TYPE MINIMUM STRENGTH HOLLOW CONCRETE M__7ONRY MASONRY CORE -',D E _ ND BEAMS EXTERIOR AND LC -,D-E=RING WALLS, WALLS EXPOSED -O E;- =TH BELOW GRADE LOAD -BEARING Vl ALLS ,,,BOVE GRADE NORMAL WEIGHT ASTM C90 GRADE N f'c = 2,150 PSI CONCRETE FILL, ASTM C476 f'g = 2.0 0 PSI TYPE M MORTAR, ASTM C270 fm = 2,500 PSI TYPE S MORTAR, ASTM C270 fm = 1,800 PSI INTERIOR NON-LCAD-E_ARING WALLS STEEL DEFORMED RE_NFORCEMENT TYPE N MORTAR, ASTM C270 fm = 750 PSI ASTM A615, GRADE 60 Fy = 60,000 PSI STEEL DEFORMED REIN=ORCEMENT FOR WELDING ASTM A706 LADDER TYPE, HOT -DIPPED GALVANIZED, ASTM A951/A153 W1.7 (9 GAGE), HOT -DIPPED GALVANIZED, ASTM A82/A153 Fy = 60,000 PSI Fy = 70,000 PSI F�-=7 �OP JOINT REINFORCE R,'EN' WIRE REINFORCEP,'EN- =0R CMU b. UUNUNL I L M- SJI.RY WALLS SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF fm = 2,000 PSI. C. SEE PLANS FCR LC -ATION OF REINFORCED WALLS. D. MINIMUM VER- CA_ REINFORCEMENT SHALL CONSIST OF (1) #4 BAR PROVIDED AT CORNERS, WITHIN 16" OF EACH S DE C = OPENINGS, WITHIN 8" OF EACH SIDE OF MOVEMENT JOINTS, WITHIN 8" OF THE ENDS OF WAL A',D AT A MAXIMUM SPACING OF 48" ON -CENTER, UNLESS NOTED OTHERWISE. E. MINIMUM HOP DON--,L REINFORCEMENT SHALL BE (2) #4 BARS PROVIDED IN BOND BEAM SPACED NOT MORE THAN 4- ON -ENTER, UNLESS NOTED OTHERWISE. F. HORIZONTAL � EINF _ RCEMENT SHALL ALSO BE PROVIDED AT THE BOTTOM AND TOP OF WALL OPENINGS AN- SHr __ EXTEND NOT LESS THAN 48 BAR DIAMETERS PAST THE OPENINGS, CONTINUOUS_ AT STRUCTURALLY CONNECTED ROOF AND FLOOR LEVELS, AND WITHIN 16" OF THE TOP OF WALLS G. CLEAR DISTA%_E BE-WEEN PARALLEL REINFORCEMENT SHALL NOT BE LESS THAN 2.5 x BAR DIAMETER. H. CONNECTION -_= IN' RSECTING WALLS SHALL CONSIST OF REINFORCED BOND BEAMS WITH (2) #4 HORIZONTAL REiNF RCEMENT AT 48" ON -CENTER MAXIMUM, AND (1) #4 VERTICAL REINFORCEMENT WITHIN 12" OF ',TEESECTING WALLS, UNLESS NOTED OTHERWISE. I. VERTICAL STEE_ SI--_L BE CONTINUOUS WITH 24" LAP AT SPLICES, UNLESS NOTED OTHERWISE. J. IN COLUMNS. = ERS ,ND PILASTERS, THE CLEAR DISTANCE BETWEEN VERTICAL BARS SHALL NOT BE LESS THAN 3 EAR D-',lETERS, NOR LESS THAN 1 1/2". K. HORIZONTAL J- iNT=EINFORCEMENT SHALL BE CONTINUOUS WITH 8" LAP SLICES, WHERE USED. L. CONCRETE BL C CK 1', ALL LINTELS: 1. EXTEND A_- LINTELS A MINIMUM OF 8" BEYOND EACH EDGE OF OPENING. WHERE LINTEL BEARS ON CONCRETE E_OCK, FILL TWO COURSES OF BLOCK MINIMUM WITH CONCRETE. 2. IF THE OPENING CCURS NEXT TO CONCRETE WALL OR COLUMN, BOLT ANGLE TO COLUMN AND REST LINTE- ON-,NGLE. OBTAIN ANGLE SIZE AND BOLT REQUIREMENTS FROM ENGINEER. 3. IF OPENING OCC_ RS NEXT TO STEEL COLUMN, WELD ANGLE TO COLUMN AND REST LINTEL ON ANGLE. OE TAIN -.%GLE SIZE AND WELD REQUIREMENTS FROM ENGINEER. M. WALL CONST= JCTIC', SHALL NOT EXCEED HEIGHTS OF 4'-8" BEFORE PLACEMENT OF CORE GROUT UNLESS CLEA,, DUT - `LES ARE PROVIDED AT THE BOTTOM OF EACH GROUT LIFT, THEN A MAXIMUM HEIGHT OF 8'-0' 3EF-_RE PLACEMENT OF CORE GROUT. N. SEE PLANS FOR SIZE AND LOCATION OF CONDUITS, PIPES, AND SLEEVES THROUGH MASONRY WALLS. 0. FOLLOW COLD .VEA--ER CONSTRUCTION WHEN AMBIENT AIR TEMPERATURE IS BELOW 40' F. P. FOLLOW HOT V.EAT!-ER CONSTRUCTION PROCEDURES WHEN AMBIENT AIR TEMPERATURE EXCEEDS 90' F WITH WIND VEL-CITY GREATER THAN 8 MPH, Q. ALL VISIBLE, NC �-VIS E-E, ABOVE -GRADE AND BELOW -GRADE JOINTS SHALL BE TOOLED IN A CONCAVE CON'!GUR--ION UNLESS SPECIFIED OTHERWISE BY ARCHITECT. STRUCTURALSTEEL A. SPECIFICATIONS: 1. DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE "STEEL CONSTRUCTION M.-NUAL", 14TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, UNLESS NOTE OTHERWISE. 2. STEEL MATERIALS SHALL MEET -HE REQUIREMENTS OF THE FOLLOWING SPECIFICATIONS, UNLESS NOTED OTHERWISE: STRUCTURAL TYPE/SHAPE ASTM DESIGNATION MATERIAL STRENGTH ANCHOR BOLTS F1554 GRADE 36 Fy = 36 KSI W SHAPE A992 Fy = 50 KSI M, S, C, MC, AND L-SHAPES, PLATES AN 3ARS A36 Fy = 36 KSI STAIR STEEL PLATE A283 GRADE C Fy = 30 KSI STAIR SHEET STEEL A653 GRADE C Fy = 36 KSI HP -SHAPE A572 GRADE 50 Fy = 50 KSI PIPES A53 GRADE B Fy = 35 KSI HSS RECTANGULAR A500 GRADE B Fy = 46 KSI HSS ROUND A500 GRADE B Fy = 42 KSI FASTENERS A325N Fnv = 48 KSI, Fnt = 90 KSI A325X Fnv = 60 KSI, Fnt = 90 KSI A490N Fnv = 60 KSI, Fnt = 113 KSI CONNECTION NUTS A490X Fnv = 75 KSI, Fnt = 113 KSI A563 WASHERS F436 WELDS E70XX ELECTRODES A233 COLD ROLLED E60XX ELECTRODES A233 FU = 70 KSI STUD ANCHORS A108 FU = 60 KSI FU = 65 KSI 1). 1 VVU UUriES Ur CERTIFIED h' __ TEST REPORTS ON ALL ASTM MATERIALS USED IN THIS WORK SHALL BE FURNISHED TO THE ENGINEER. 4. ALL STAINLESS STEEL SHALL E= TYPE S30400/S30403 DUAL CERTIFIED OR S30403 (S304L), UNLESS NOTED OTHERWISE. 5. ALL ASTM A325 BOLTS EXPOS TO EXTERIOR CONDITIONS SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM Al__ ASTM 490 BOLTS SHALL NOT BE GALVANIZED. 6. CLEAN ALL EXTERIOR FIELD 1', E_DS AND MEMBERS PER SSPC-SPG AND PRIME PAINT WITH GRAY INORGANIC ZINC TO A 3-5 MIL--ICKNESS. B. DESIGN STRESS: 1. MINIMUM BEAM CONNECTIONS SHALL NOT BE SMALLER THAN THOSE LISTED IN PART 10 OF THE AISC MANUAL. 2. UNLESS DETAILED OTHERWISE MAKE CONNECTIONS WITH E70XX ELECTRODES OR BOLTED WITH 3/4" A325 BOLTS IN BEARING - :)E CONNECTIONS WITH THREADS IN THE SHEAR PLANE (A325N). C. WELDING: 1. ALL WELDING SHALL CONFOF'•' TO THE REQUIREMENTS OF AWS D1.1 STRUCTURAL WELDING CODE. 2. WELDER CERTIFICATION PRC= EDURES SHALL BE AS FOLLOWS: a. ALL WELDERS SHALL BE C _ RRENTLY CERTIFIED AND REGISTERED BY THE LOCAL OFFICIALS AND/OR THE AMERICAN V E-DING SOCIETY AND, IF REQUIRED, ALL WELDERS SHALL HAVE THEIR CERTIFICATION AV.- -ABLE TO THE ENGINEER. 3. ALL WELD FILLER METAL SHA__ BE AWS E70XX WITH A MINIMUM CHARPY V-NOTCH (CVN TOUGHNESS OF 20FT-LB AT C -EG F, AS DETERMINED BY THE APPROPRIATE AWS A5 CLASSIFICATION TEST METHC- OR MANUFACTURER CERTIFICATION, UNLESS NOTED OTHERWISE. 4. WELDS DESIGNATED AS DEM-''.D CRITICAL (DC) SHALL BE MADE WITH A FILLER METAL CAPABLE OF PROVIDING A MINIMUM CV', -OUGHNESS OF 20 FT -LB AT -20 DEG F AND 40 FT -LB AT A TEMPERATURE OF 70DEG F AS DETERMINED BY THE MANUFACTURER'S CERTIFICATION, AISC 341-05 APPENDIX X, OR OTHE= ;PPROVED METHOD. WELD FILLER METALS SHALL NOT BE USED FROM PACKAGING THAT HAS E EEN PUNCTURED OR TORN, OR IF THE MANUFACTURER'S RECOMMENDATIONS FOR EX:: SURE TIME OR DRYING PROCEDURES HAVE NOT BEEN FOLLOWED. 5. ALL BUTT WELDS SHALL BE C-'.1PLETE JOINT PENETRATION (CJP) WELDS, UNLESS NOTED OTHERWISE. 6. ALL GROOVE WELDS SHALL EE COMPLETE JOINT PENETRATION (CJP) WELDS, UNLESS NOTED OTHERWISE, 7. WELDING PROCEDURE AND SE)UENCES SHALL BE PLANNED TO MINIMIZE WELD SHRINKAGE THAT COULD RESULT IN LAMELLAF -FARING. 8. FIELD WELDING WILL BE ALL- .','ED ONLY WHERE SHOWN ON THE DRAWINGS. 9. EXISTING AND NEW STEEL S_ ==ACES TO BE WELDED SHALL BE CLEANED OR PAINT, GREASE, SCALE, OR OTHER FOREIGN '•'-TERIAL REMOVED. 10. ALL FIELD WELDS SHALL BE'.'. RE BRUSHED AND CLEANED, THEN TOUCHED -UP PAINTED. D. MISCELLANEOUS METAL 1. WORK INCLUDES LGvTELS SIMRS, PANS, HANDRAILS, GUARDRAILS, POSTS, ETC. 2. FABRICATION: a. FABRICATE STAIRS YVITH CLOSED RISERS AND TREADS OF METAL PAN CONSTRUCTION READY TO RECEIVE CONCRETE, JNLESS NOTED OR DETAILED OTHERWISE IN THE CONSTRUCTION DOCUMENTS. b. FORM LANDINGS WITH S-EET STEEL STOCK. c. FORM STRINGERS WITH STEEL PLATE OR CHANNELS. d. FIT AND SHOP ASSEMBLE HANDRAIL COMPONENTS WHERE POSSIBLE. GRIND EXPOSED JOINTS FLUSH AND SMOG-H. e. SHOP PRIME WITH TWO CDATS. E. STRUCTURAL STEEL SHOP DRA',', iNGS SHALL INCLUDE CALCULATIONS THAT SUMMARIZE ANY CONNECTION REVISIONS, THIS DOCUMENT IS THE PROPERTY OF I & S GROUP, INC. AND MAY NOT BE USED, COPIED OR DUPLICATED WITHOUT PRIOR WRITTEN CONSENT. PROJECT 5 SULLIVAN BROTHERS CONVENTION CENTER LINTEL REPLACEMENT WATERLOO IOWA REVISION SCHEDULE ' DATE DESCRIPTION gY PROJECT NO. 19-23187 FILE NAME 19-23185-5 Sullivan Bros Project Arch 20 DRAWN BY RRB DESIGNED BY JEH REVIEWED BY JEH, ORIGINAL ISSUE DATE 09/18/19 CLIENT PROJECT NO TITLE STRUCTURAL SHEET NOTES 10/4/2019 9:47:34 AM 2S1-00