Loading...
HomeMy WebLinkAboutscan-17RL RL RS RS CONDENSING UNIT �-- EX ROOF ►+ RAILS NOTES: 1. INSULATE REFRIGERANT SUCTION & GAS LINES W/3/4" ARMAFLEX PIPE INSULATION. USE RIGID ARMAFLEX AT ALL PIPE HANGER LOCATIONS. 2. REFRIGERANT LINES SHALL BE SIZED BY THE EQUIPMENT MANUFACTURER. 3. ON SMALL SIZED DX SYSTEM, EQUIPMENT. SHOWN ON LIQUID LINE MAY BE FURNISHED WITH UNIT. MECHANICAL CONTRACTOR TO VERIFY. ---EX ROOF OPENING - FILTER DRYER (TYR) --LIQUID LINE SIGHT GLASS & MOIST. INDICATOR (TYP.) ---SOLENOID VALVE WIRED BY MECHANICAL (TYP.) -OIL TRAP CONSIST. OF STREET ELBOW (TYP.) DUAL -CIRCUIT -CONDENSING UNIT HIGH DETAIL 3- No Scale - - -THERMAL EXPANSION VALVE W/REMOTE SENSING BULB - -- AIR FLOW CONDENSATE DRAIN PAN - CD -I ---CONDENSATE DRAIN LINE TO FLOOR DRAIN EX MAIN SWITCHGEAR 2500A, 480V/277V, 30, 4VV -^ 90A-3P 0/3 Anus 3 nE T � 20A-3P �1 r �3 Anu o r.v iv 25A-3P 25/3 ACCU-3A 25A-3P �ACC 25/37 EX 2500A-3P ELECTRICAL RISER DIAGRAM 5 %o Scam NOTE: REFER TO SPECIFICATIONS FOR 360 DEGREE INSERT INFORMATION. SPECIFIED INSULATION • CORNERS ARE CLIPPED PIPE HANGER (SEE SPECS) PIPE SADDLE WITH FLARED - EDGES NOTCHED TO FIT PIPE HANGER, TO SPAN 180° �J FLARED _/ SPECIFIED EDGES LENGTH = 12" INSULATION ALL INSULATION 360 DEGREE SHALL PASS UNBROKEN -- INSERT (SEE SPEC) - THROUGH HANGER 2 INSULATED PIPE HANGER DETAIL No Scale GENERAL NOTES: A. MAINTAIN ALL SERVICE CLEAti=NCE_ REQUIRED BY THE UTILITY. B. UTILITY CONTACT: MID AMEF-rAN C. INSTALL ALL CONDUCTORS = MA'.--ACTURER'S RECOMMENDATIONS, CONDUCTOR AND CONDUIT SIZING CHART CONDUCTORS(T-,IN-_ CONDUIT PARALLEL PHASE NEUTR-_ :;ROUND EMT RMC RUNS 20/3 ;3) #12 AWG - =:? AWG 1/2" 3/4" 1 25/3 (3)#10 AWG _3 AWG 1/2" 3/4" 1 90/3 (3) #3 AWG AWG 1-1/4" 1-1/4" 1 AHU-3 MODULES O1. AIR MIXING SECTION O2. ACCESS SECTION 30. ELECTRIC HEAT SECTION O4. COOLING COIL SECTION O5. ACCESS SECTION O6. SUPPLY FAN SECTION BEAD OF 3M FIRI BARRIER CP 25N/S CAULI RIER 'STRIP 2" MAX. GLASS FIBER PIPE INSULATION "•TE, F-t ADDITIONAL FIRE PROOFING "ETHODS AND MATERIALS CONTACT A -M FIRE PROTECTION DISTRIBUTOR. EL 1 OR 2 HR. FIRE RATED WALLBOARD A 1 HOUR INSULATED PIPE/DUCT AND 2 HOUR INSULATED PIPE DETAIL No Scale - - - - -- - - - - EX--'x20'EA Y EX 12"x36" OA 0 RS/RL -AHU-3 5 SIZED BY 6 -MANUR O ��� O O H O5 O E' :ONCRETE PADS '-NEW CONCRETE PAD 4 AHU-3 MODULES - .14'=1 - - AIR HANDLING UNIT SCHEDULE T SUPPLY FAN ._ _ _ELECTRIC HEAT -_- _ -__.. - COOLING COIL - ELECTRICAL DIMENSIONS '� WEIGHT AIRFLOW TSP (IN. ESP (IN. MOTOR MOTOR EAT/LAT OUTPUT FACE VELOCITY FACE AREA APD (IN.! TOTAL CAPACITY SENSIBLE CAPACITY EADBIWlITADB/wB FACEVELOCITY FACE AR� FIN SPACING FIN HEAT HEAT FAN FAN VOLTAGE/ UNIT _ MANUFACTURER MODEL (W"xL"xH') (LBS) (CFM) - _ H2O) H2O) BHP HP (°F) (kW) (FPM) _(SQ. FT.) H2O) STAGES - (MBH) (MBOH)- (°F) (°F) (FPM)_ _ (SQ. FT.) '.. STAGESTI, (PER FOOT) MATERIAL FILTERS MCA M_OCP MCA MOCP PHASE AHU 3 -RA\E CSAA014 '�. 7L0"x144 6 x4L5" ! 2,053 6.400 2.61 ..00 3.69 5.0 45.E 78.0 56.8 - 11.7 0._ 4 229 3 1 77.0/6S.0 54.1/52.9 476 13. 114 ALUMINUM 2 MERV 8 84.07 j 90 6.83 15 460V/30 NU I t: 1. PRO VIDE UNDER A-D ALTER'ATES #8 AND #9. 2. U^::T SHALL HA • E' ;N. SCCR RATING OF 65,000 A. EXHAUST FAN SCHEDULE AIRFLOW S.P.-FAN VOLTAGE/ UNIT !MANUFACTURER MODEL (CFM) (IN.) RPM i BHP HP SONES MCA MOCP PHASE EF = GREEN-- -e I G-143-• -- ! 2,220 0.25 1,296 1 0.44 0.75 13.0 8.25 15 208V'10 NOTE- 1. F]VIDE UNDEF=U ALTERNATE =9 ONLY. 2. FR=VIDE FAN V+T- GRAVITY TYFE _'ACKDRAFT DAM=ER. 3. PF= 1IDE UNIT V, T-- SHAFT GROU'•= ING KIT OR IN'• r-RTER DUTY MOTOR FOR USE WITH VFD. AIR-COOLED CONDENSING UNIT SCHEDULE UNIT MANUFAC_TUR_ER MODEL TTA120 TTA120 . CAPACITY (TON--S>�-----------������TAGES 1D _0 _REFRIGERANT CIRCUITS _ R 4' = 1 ! R 41-= 1 WEIGHT (LBS) T MCA MOCP VOLTAGE/PHASE ACCU-3A TRANE 416.5 416.5 20 20 25 25 460V/30 460V/30 ACCU-3B TRANE No I t]: 1. PROVIDE UNDER BASE-D AND ADD ALTERNATES. 2. UNITS SHALL HAVE MI'• SCCR RATINGS OF 65,000 A. COOLING COIL SCHEDULE COIL PERFORMANCE COIL FINS AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY EADB/WB LADB/WB FACE VELOCITY APD (IN. DIMENSIONS SPACING FACE AREA UNIT MANUFACTURER MODE (CFM) 6,400 _ (MBH) _ (M_BH) (°F) (°F) _ (FPM) 236.4 168 - 77.0/65 0-3.0/52.6 457 H2O) -.73 (H"xL") (FINS/IN.) (SQ. FT.) ROWS MATERIAL 1 31.5"x64.0" 12 14.0 1 4 ALUMINUM CC-3 PRECISION COILS DMSSr4S12 NOTES', 1. PROVIDE UNDER BASE BID ONLY, NOTE: ALL MECHANICAL EQAPMENT FEED COMPONENT SH(c.- CIRCUIT CURRENT RATINGS SCCR) SHALL MEET CR EXCEED -HE MA\IMUM AIC RATING OF THE ELECTRICAL PANEL IN VMICH IT IS SER, ED. REFER TO ELECTRICAL PANE_ SCHEDULES FOR REQUIRED PA',EL AIC RATINGS. AL RNATIV ELY, THE CONTRACTOR MAY PROVIDE THE NECESSARY CALCULATIO'.S TO PROVE THE MECHANICAL EQ_:�MENT SCCR RATING PROVIDE) EXCEEDS THE SHOR- CIRCUIT CURREG' AVAILABLE AT THE EQUIPME"•-. NOTE: VERIFY BUILDING DIMENSIONS FOR ROUGH -IN' WORK WITH ARCHITECTS DRAWINGS. INVISION 11N.INc IA•Rcr;rEcruRE I iNreRioas 501 Sycamore Street Suite 101 Waterloo, IA 50703 's 319.233.8419 319-233.9772 Fax www.invisionarch.com CONSULTANT: mvuuzno WATERLOODES MOINES IOWA CITY REVISIONS: Description Date No. OWNER SIGN -OFF: DATE NAME U_ o Z 0 Q ry = U-i U w 3 I F- (/) Z Q Z LLJ W V) Q Z 0 Z ::D (� U � O N PROJECT NO: 19053 DATE: 2019.08.06 SHEET SET: BID DOCUMENTS SHEET NAME: DETAILS & SCHEDULES SHEET: ME5.00 19-068 YOUNG ARENA MECHANICAL UPGRADES