Loading...
HomeMy WebLinkAboutALDI, INC. - 1918 SCHUKEI RD OF W q TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE A , Pe 10/02/2026 11/06/2026 2027-00000145 $100.00 • •II ■Il nun u1 • > t T O 4S 7 v 17N� Customer#: 7728 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ALDI'S INC 715 Mulberry St 4201 BAGLEY AV N WATERLOO, IA 50703 FAIRBAULT, MN 55021 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION -1918 SCHUKEI RD-09/17/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 7728 10/02/2026 11/06/2026 2027-00000145 $100.00 • Less Prepayment $0.00 Total Due-* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue OS Inspection Report 425 E.3rd Street 4420 Aidi Inc-1918 Schukei RD,BLDG 1918 Schukei Rd,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 09/17/2026 Annual Inspection(1Yr) '7?as 4 I 1 18666 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION � 45 07 C23 Passed codes Failed codes NIA Codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 10I0912026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09/17/2026 @ 14:27 Fire extinguishers due annually serviced in July 2027 BRAD BALDWIN-0911712026 @ 14:27 •If all corrections are made before the scheduled re-inspection date,you can call to setup an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m....**Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at 5100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-09117/2026 @ 14:27 •Provide corrections to avoid progressive re-inspection fees beginning at 5100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-0 9/1712 0 2 6 @ 14:27 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(N0)-Cell:319-230-1224 BRAD BALDWIN-09117/2026 @ 14:26 •$100 annual inspection fee SIGNATURES Contact signature Inspector signature No signature post inspection Report completed post Curtis Dunlap DM 2026 Date: BRAD BALDWIN 09/18/2026 CHECKLISTS GENERATED ON 9/IE/2O, 8,46 AH 1 OF Means of Egress Status Code Description Fail 1010.1.3-Door opening force Forces to unlatch and open doors. Location:Alarmed exit doors(3) The force for pushing or pulling open interior swinging Comments:Unable to test doors due to on-site staff did not have egress doors,other than fire doors,shall not exceed 5 access to alarm keys.Provide keys so Inspector can test door pounds(22 N).These forces do not apply to the force operation required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set • in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Emergency Equipment St Description Fail 1203.4.3-Records. Records of the inspection,testing and maintenance of Location:Entire building emergency and standby power systems shall include the date Comments:Provide documentation of all egress lighting and exit of service,name of the servicing technician,a summary of sign test and repaired if necessary to maintain working properly. conditions noted and a detailed description of any conditions Email documentation to inspector including signed and dated. requiring correction and what corrective action was taken. Such records shall be maintained. GENERATED ON S/18/2i, 8:.46 AM 2 OF 7 Electrical Safety Status Code Description Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Location: Southwest parking lot Identified electrical hazards shall be abated. Identified Comments: Replace missing light post shroud exposing wires. hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. ERA cr- 01b. r4 4 a ' - y T 'xa • • GENERATED ON 9/18/28, 8:4G AM 3 OF 7 , Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Back room near break room maintained in accordance with this section and NFPA 10. Comments:Fire extinguisher requires annual inspection-Contractor Exceptions:1.The distance of travel to reach an extinguisher failed to punch date of inspection on tag needs corrected. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. / y., r GENERATED ON 9/18/26, 8:46 AM 4 OF 7 Fail 906.6-Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or Location:Back room-Near walk in freezer obscured from view.In rooms or areas in which visual Comments:Obstructions to access fire extinguisher shall be obstruction cannot be completely avoided,means shall be removed.Maintain clear access at all times. provided to indicate the locations of extinguishers. T r .11151'- ill 61 Fail 906.6-Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or Location:Back room near dock door obscured from view.In rooms or areas in which visual Comments:Obstructions to access fire extinguisher shall be obstruction cannot be completely avoided,means shall be removed.Maintain clear access at all times.Relocate coat hook to provided to indicate the locations of extinguishers. avoid blocking view of extinguisher GENERATED ON W118/26, 8;46 AM 5 OF 7 Additional Codes Slants Code Description Fail 907.8.4-Inspection,testing and maintenance. The building owner shall be responsible to maintain the fire Location:Near main exit and life safety systems in an operable condition at all times. Comments:Fire alarm annunciator panel double sided tape has Service personnel shall meet the qualification requirements become loose from wall.Panel shall be mounted properly to avoid of NFPA 72 for inspection,testing and maintenance of such hanging by wires systems.Records of inspection,testing and maintenance shall be maintained. 1 \ V\ a / • i I i / GENERATED ON 9/18/26, 8:46 AM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/18/28, 8:48 Al 7 OF 7