COMMERCIAL FIRE INSPECTION -1918 SCHUKEI RD-09/17/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
7728 10/02/2026 11/06/2026 2027-00000145 $100.00
•
Less Prepayment $0.00
Total Due-* $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
OS Inspection Report 425 E.3rd Street
4420 Aidi Inc-1918 Schukei RD,BLDG 1918 Schukei Rd,Waterloo IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
09/17/2026 Annual Inspection(1Yr) '7?as 4 I 1 18666
Lead Inspector Shift Station Unit
BRAD BALDWIN NIA NIA N/A
Other Inspectors
NIA
SUMMARY OF INSPECTION
� 45 07 C23
Passed codes Failed codes NIA Codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN 10I0912026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-09/17/2026 @ 14:27
Fire extinguishers due annually serviced in July 2027
BRAD BALDWIN-0911712026 @ 14:27
•If all corrections are made before the scheduled re-inspection date,you can call to setup an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m....**Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at 5100,then$150,and$200 for all subsequent re-inspections.
BRAD BALDWIN-09117/2026 @ 14:27
•Provide corrections to avoid progressive re-inspection fees beginning at 5100.Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-0 9/1712 0 2 6 @ 14:27
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(N0)-Cell:319-230-1224
BRAD BALDWIN-09117/2026 @ 14:26
•$100 annual inspection fee
SIGNATURES
Contact signature Inspector signature
No signature post
inspection
Report completed post
Curtis Dunlap DM 2026 Date: BRAD BALDWIN 09/18/2026
CHECKLISTS
GENERATED ON 9/IE/2O, 8,46 AH 1 OF
Means of Egress
Status Code Description
Fail 1010.1.3-Door opening force Forces to unlatch and open
doors. Location:Alarmed exit doors(3)
The force for pushing or pulling open interior swinging Comments:Unable to test doors due to on-site staff did not have
egress doors,other than fire doors,shall not exceed 5 access to alarm keys.Provide keys so Inspector can test door
pounds(22 N).These forces do not apply to the force operation
required to retract latch bolts or disengage other devices that
hold the door in a closed position.For other swinging doors,
as well as sliding and folding doors,the door latch shall
release when subjected to a 15-pound(67 N)force.The door
shall be set in motion when subjected to a 30-pound(133 N)
force.The door shall swing to a full-open position when
subjected to a 15-pound(67 N)force.The forces to unlatch
doors shall comply with the following:1.Where door
hardware operates by push or pull,the operational force to
unlatch the door shall not exceed 15 pounds(66.7 N).2.Where
door hardware operates by rotation,the operational force to
unlatch the door shall not exceed 28 inch-pounds(315 N-cm).
The force to open doors shall comply with the following:
1.For interior swinging egress doors that are manually
operated,other than doors required to be fire rated,the force
for pushing or pulling open the door shall not exceed 5
pounds(22 N).2.For other swinging doors,sliding doors or
folding doors,and doors required to be fire rated,the door
shall require not more than a 30-pound(133 N)force to be set •
in motion and shall move to a full-open position when
subjected to not more than a 15-pound(67 N)force.
Emergency Equipment
St Description
Fail 1203.4.3-Records.
Records of the inspection,testing and maintenance of Location:Entire building
emergency and standby power systems shall include the date Comments:Provide documentation of all egress lighting and exit
of service,name of the servicing technician,a summary of sign test and repaired if necessary to maintain working properly.
conditions noted and a detailed description of any conditions Email documentation to inspector including signed and dated.
requiring correction and what corrective action was taken.
Such records shall be maintained.
GENERATED ON S/18/2i, 8:.46 AM 2 OF 7
Electrical Safety
Status Code Description
Fail 603.2 - Abatement of unsafe conditions and electrical
hazards. Location: Southwest parking lot
Identified electrical hazards shall be abated. Identified Comments: Replace missing light post shroud exposing wires.
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
ERA
cr-
01b.
r4 4 a '
- y
T 'xa
•
•
GENERATED ON 9/18/28, 8:4G AM 3 OF 7
,
Portable Fire Extingusihers
Status Code Description
Fail 906.2-General requirements.
Portable fire extinguishers shall be selected,installed and Location:Back room near break room
maintained in accordance with this section and NFPA 10. Comments:Fire extinguisher requires annual inspection-Contractor
Exceptions:1.The distance of travel to reach an extinguisher failed to punch date of inspection on tag needs corrected.
shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device,provided that all of the
following conditions are met:2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal.2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10.3.In Group 1-3,portable fire
extinguishers shall be permitted to be located at staff
locations.
/
y., r
GENERATED ON 9/18/26, 8:46 AM 4 OF 7
Fail 906.6-Unobstructed and unobscured.
Portable fire extinguishers shall not be obstructed or Location:Back room-Near walk in freezer
obscured from view.In rooms or areas in which visual Comments:Obstructions to access fire extinguisher shall be
obstruction cannot be completely avoided,means shall be removed.Maintain clear access at all times.
provided to indicate the locations of extinguishers.
T
r
.11151'-
ill 61
Fail 906.6-Unobstructed and unobscured.
Portable fire extinguishers shall not be obstructed or Location:Back room near dock door
obscured from view.In rooms or areas in which visual Comments:Obstructions to access fire extinguisher shall be
obstruction cannot be completely avoided,means shall be removed.Maintain clear access at all times.Relocate coat hook to
provided to indicate the locations of extinguishers. avoid blocking view of extinguisher
GENERATED ON W118/26, 8;46 AM 5 OF 7
Additional Codes
Slants Code Description
Fail 907.8.4-Inspection,testing and maintenance.
The building owner shall be responsible to maintain the fire Location:Near main exit
and life safety systems in an operable condition at all times. Comments:Fire alarm annunciator panel double sided tape has
Service personnel shall meet the qualification requirements become loose from wall.Panel shall be mounted properly to avoid
of NFPA 72 for inspection,testing and maintenance of such hanging by wires
systems.Records of inspection,testing and maintenance
shall be maintained.
1 \ V\
a
/ •
i I
i
/
GENERATED ON 9/18/26, 8:46 AM 6 OF 7
Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $100.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 9/18/28, 8:48 Al 7 OF 7