Loading...
HomeMy WebLinkAboutCOUNTRY INN & SUITES-4025 HAMMOMD AVE OF W A 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 o 10/02/2026 11/06/2026 2027-00000148 $100.00 • •IA III II • Customer#: 7011 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable COUNTRY INN & SUITES 715 Mulberry St 4025 HAMMOND AVE WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION -4025 HAMMOND AVE-09/21/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 7011 10/02/2026 11/06/2026 2027-00000148 $100.00 Less Prepayment $0.00 Total Due—* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street Country Inn&Suites-4025 Hammond AVE,BLDG 4025 Hammond Ave,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 09/2112026 Annual Inspection(1Yr) .()' I U 1���JJJ���1"' cyo 22961 Lead Inspector Shift //! Station Unit BRAD BALDWIN N/A NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION C 43 39 ® 19 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 10/15/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09/2212026 @ 14:07 Annual fire alarm inspection and report to be uploaded to Compliance Engine due 1113126. BRAD BALDWIN-0912212026 @ 13:18 House laundry dryer vent annual cleaning-Done by Harris cleaning November 2025 BRAD BALDWIN-0912212026 @ 08:26 Fire extinguishers due annually serviced January 2027 BRAD BALDWIN-09/2212026 @ 08:26 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-09122/2026 @ 08:26 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-09122/2026 @ 08:25 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-09122/2026 @ 08:25 •$100 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 9/22/26, 2:10 PM 1 OF 14 Jay Patel-2028 Date: CHECKLISTS BRAD BALDWIN 09122/2026 GENERATED ON 9/22/28, 2:10 PM 2 OF 14 Additional Codes an, Code Description Fail 1028.3•Exit discharge width or capacity. The minimum width or required capacity of the exit discharge Location:NW exit shall be not less than the minimum width or required capacity Comments:Trim bushes to avoid obstructing full width of exit of the exits being served. discharge. Fall 610.1.2-Maintenance. OThe lint trap,mechanical and heating components,and the Location:Guest laundry dryer vent exhaust duct system of a clothes dryer shall be maintained in Comments:Provide documentation of dryer vent cleaned from the accordance with the manufacturer&#039;s operating appliance to the exterior of the building. instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Fail 704.2-Repair of joints and voids. >C9 Where damaged,materials used to protect joints and voids Location:Room 202 shall be replaced or restored with materials or systems that Comments:Missing escutcheons or improper escutcheons shall be meet or exceed the code requirements applicable at the time replaced. when the assembly was constructed,remodeled or altered. Fail 901.6-Inspection,testing and maintenance. Fire detection and alarm systems,emergency alarm systems, Location:Sprinkler system gas detection systems,fire-extinguishing systems, Comments:Licensed contractor shall make repairs to deficiencies mechanical smoke exhaust systems and smoke and heat (see attached)noted in Black Hawk Sprinkler inspection report vents protection and life safety systems shall be maintained #10143710.Repair report shall then be uploaded to Compliance in an operative condition at all times,and shall be replaced or Engine. repaired where defective.Nonrequired fire protection and life safety systems and equipment shall be inspected,tested and maintained or removed in accordance with Section 901.8. en o Fail 907.2.11.1-Group R-1. Single-or multiple-station smoke alarms shall be installed in Location:All sleeping rooms all of the following locations in Group R-1:1.In sleeping Comments:Provide documentation of smoke detectors in all rooms areas.2.In every room in the path of the means of egress are present,have been tested and are working properly.Document from the sleeping area to the door leading from the sleeping shall be emailed to inspector. unit.3.In each story within the sleeping unit,including basements.For sleeping units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. GENERATED ON 9/22/28, 2:10 PM 3 OF 14 Fail 907.8.4-Inspection,testing and maintenance. The building owner shall be responsible to maintain the fire Location:Pool room storage and life safety systems in an operable condition at all times. Comments:Fire alarm device shall be corrected to avoid hanging by Service personnel shall meet the qualification requirements wires. of NFPA 72 for inspection,testing and maintenance of such systems.Records of inspection,testing and maintenance shall be maintained. .5 h - r . • Emergency Equipment Status lode Description Fail 1203.2.15-Means of egress illumination. Ox Emergency power shall be provided for means of egress Location:Pool-Above hot tub illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light that failed to illuminate during test GENERATED ON 9/22/28, 2:10 PM 4 OF 14 Fire Sprinkler System 5[ cc, Description Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Near main front doors obstructions that will delay activation or obstruct the water Comments:Licensed contractor shall replace plugged sprinkler distribution pattern and shall be in accordance with the head applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Q� P GENERATED ON 0/22/20, 2:10 PM 5 OF 14 Fire Service Features Status Gorse Description Fail 505.1•Address identification. New and existing buildings shall be provided with approved Location:Front of building(facing Hammond Ave) address Identification.The address identification shall be Comments:Install permanent address identification numbers in legible and placed in a position that is visible from the street contrast with the building,easily visible from the road(minimum 4"in or road fronting the property.Address identification height) characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 112 inch(12.7 mm).Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. Fail 506.2-Key box maintenance. The operator of the building shall immediately notify the fire Location:Knox Box code official and provide the new key where a lock is changed Comments:Contact Waterloo Fire Department at 319-291-4460 and or rekeyed.The key to such lock shall be secured in the key provide copy of all master keys for Knox Box box. Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:3rd floor-Dry Sprinkler Riser Room protection system equipment to permit immediate safe Comments:Remove storage within 36"of sprinkler equipment and operation and maintenance of such equipment.Storage,trash maintain clear ready access at all times. and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:1st floor-Sprinkler Riser Room protection system equipment to permit immediate safe Comments:Remove storage(ladder,softener salt and snow blower) operation and maintenance of such equipment.Storage,trash within 36"of sprinkler equipment and maintain clear ready access to and other materials or objects shall not be placed or kept in equipment at all times. such a manner that would prevent such equipment from being readily accessible. GENERATED ON 9/22/26, 2:10 PM 6 OF 14 Electrical Safety States Cone Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Pool equipment room prohibited.Approved covers shall be provided for all switch Comments:Blower electrical installation shall be contained as and electrical outlet boxes. manufactured to avoid exposed wire connection. .rt tor- qk : . t a Fail 603.5.2-Application and usePower supply. ORelocatable power taps and current taps shall be directly Location:Office-1st floor connected to a permanently installed receptacle.Exceptions: Comments:Remove power strip plugged to another power strip 1.Where approved for use in a Group A occupancy or in a behind computer,must plug directly to a wall outlet meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. GENERATED ON 9/22/20, 2:10 PM 7 OF 14 Fire Resistant Construction Maintenance Status Code Description Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:2nd floor electric room-near vending materials and systems used to protect joints and voids in the Comments:Pipe penetration through ceiling and floor shall be sealed following locations shall be maintained.The materials and to maintain proper fire rating. systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or rooflceiling assemblies.2.3oints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer&#039;s installation instructions. Y 1 �< M1I f tt 1 ` r - d t .i`r !. 4 i' e -. r r tit ' 4 .� 6 t� t;t / c r:f C -.ti y' 1 ,.5(ti' .,.r 1. a; � a ' I Y GENERATED ON 9/22/26, 2:10 PM 8 OF 14 Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Pool equipment room materials and systems used to protect joints and voids in the Comments:Hole in ceiling needs repaired to maintain proper fire following locations shall be maintained.The materials and rating.A building systems shall be securely attached to or bonded to the permit and inspection will be required If repair is larger than 1 Sq Ft in size due to hole in fire wall. adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floorlceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer&#039;s installation instructions. j 411�r 4, 1�3i� • 4,7 0' 4, I- S e • • iv `Y §.k. ; :*fit .#:xk.• e GENERATED ON 9/22/2G, 2:10 PM 9 OF 14 Fall 704.1-Maintaining protection. 0 Where required when the building was originally constructed, Location:Pool mechanical room materials and systems used to protect joints and voids In the Comments:Pipe penetration through walls shall he sealed to following locations shall be maintained.The materials and maintain proper fire rating. systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints In or between lire-resistance-rated walls,floors or floor/ceiling assemblies and roof or rooffceiling assemblies.2.Jolnts in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Volds at the Intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfiire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonf ire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer&#039;s installation instructions. Fail 705.2-Inspection and maintenance. OOpening protectives in fire-resistance-rated assemblies shall Location:3rd floor elevator fire drop doors be inspected and maintained in accordance with NFPA 80. Opening Comments:Carefully remove paint covering frame fire rating labels. p g protectives in smoke barriers shall be inspected and Removal of label of information on label requires re-certification or maintained in accordance with NFPA 80 and NFPA 105. replacement. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105.Fire doors and smoke and draft control doors shall not be blocked, obstructed,or otherwise made inoperable.Fusible links shall be replaced promptly whenever fused or damaged.Opening protectives and smoke and draft control doors shall not be modified. Fail 705.2-Inspection and maintenance. OOpening protectives in fire-resistance-rated assemblies shall Location:All required fire rated door frames in building. be inspected and maintained in accordance with NFPA 80. Comments:Frames missing properly rated smoke seals shall be Opening protectives in smoke barriers shall be inspected and installed.Retain documents of smoke seals to provide to inspector. maintained in accordance with NFPA 80 and NFPA 105. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105.Fire doors and smoke and draft control doors shall not be blocked, obstructed,or otherwise made inoperable.Fusible links shall be replaced promptly whenever fused or damaged.Opening protectives and smoke and draft control doors shall not be modified. Fail 705.2-Inspection and maintenance. OOpening protectives in fire-resistance-rated assemblies shall Location:New key reader door hardware for all sleeping rooms be inspected and maintained in accordance with NFPA 80. Comments:Provide documentation of hardware includes proper fire Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105. rating,email documents to inspector. Openings in smoke partitions shall be inspected and maintained In accordance with NFPA 105.Fire doors and smoke and draft control doors shall not be blocked, obstructed,or otherwise made inoperable.Fusible links shall be replaced promptly whenever fused or damaged.Opening protectives and smoke and draft control doors shall not be modified. uesenaTED ON g/22/26, 2:10 PM 10 OF 14 � 4 Fail 705.2.4• Door operation. O Swinging fire doors shall close from the full-open position Location: 3rd floor elevator drop doors and latch automatically, Comments: Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4- Door operation. OSwinging fire doors shall close from the full-open position Location: Room 320 and latch automatically. Comments: Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4 - Door operation. Ox Swinging fire doors shall close from the full-open position Location: Room 310 and latch automatically. Comments: Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4 - Door operation. OSwinging fire doors shall close from the full-open position Location: Room 301 and latch automatically. Comments: Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4 - Door operation. 0 V Swinging fire doors shall close from the full-open position Location: 3rd floor stairwell door - near room #391 and latch automatically. Comments: Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4 - Door operation. 0 Swinging fire doors shall close from the full-open position Location: 2nd floor stairwell door - near room #203 and latch automatically. Comments: Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4 - Door operation. Ux Swinging fire doors shall close from the full-open position Location: 2nd floor electric room - near vending machines and latch automatically. Comments: Remove door hold-open device, required fire rated doors shall self-close and latch. Fail 705.2.4 - Door operation. Swinging fire doors shall close from the full-open position Location: 2nd floor elevator fire drop doors and latch automatically. Comments: Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4 - Door operation. 0 Swinging fire doors shall close from the full-open position Location: 1st floor stairwell door - near room #129 and latch automatically. Comments: Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4- Door operation. Swinging fire doors shall close from the full-open position Location: 1st floor closet near room #129 and latch automatically. Comments: Repair or replace fire doors that failed to self-close and latch. Door missing closure, closure and all door hardware shall include proper fire rating. Fail 705.2.4 - Door operation. Swinging fire doors shall close from the full-open position Location: Room 119 and latch automatically. Comments: Repair or replace fire doors that failed to self-close and latch. GENERATED ON 9/22/2G, 2:1A PM 11 OF 14 Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:Room 116 and latch automatically. Comments:Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:1st floor laundry and latch automatically. Comments:Remove door hold-open device,required fire rated doors shall self-close and latch Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:1st floor stairwell door-near pool entry and latch automatically. Comments:Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4-Door operation. () Swinging fire doors shall close from the full-open position Location:2nd floor electric room-near vending machine and latch automatically. Comments:Remove door hold-open device,required fire doors shall self-close and latch. Fail 705.2.4-Door operation. OSwinging fire doors shall close from the full-open position Location:1st floor-Sprinkler Riser Room and latch automatically. Comments:Repair or replace fire doors that failed to self-close and latch. Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:Guest laundry room and latch automatically. Comments:Repair or replace fire doors that failed to self-close and latch,door missing latch GENERATED ON 9/22/28, 2:10 PM 12 OF 14 Portable Fire Extingusihers orI, Description Fail 906.1-Where required. Portable fire extinguishers shall be installed in all of the Location:Front desk following locations:1.In new and existing Group A,B,E,F,H, Comments:Remove residential listed extinguisher.Current required I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group extinguishers are in place as needed. R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use.3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4. Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1;1-2,Condition 1;and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Fail 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets, Location:Pool mechanical room shall be installed on the hangers or brackets supplied. Comments:Fire extinguisher on shelf shall be mounted on wall Hangers or brackets shall be securely anchored to the bracket 4"above floor and maximum 5'from floor in height mounting surface in accordance with the manufacturer's installation instructions. GENERATED ON 9/22/26, 2:10 PM 13 OF 14 Fo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number N/A N/A NIA GENERATED ON 9/22/26, 2:10 PM 14 OF 14