COMMERCIAL FIRE INSPECTION -3729 UNIVERSITY AVE- FOR BILLING INQUIRY: (319)291-4323
09/28/26
IDescription
Total Price
INSPECTION 20,000 $90.00
OCCUPANCY FEE
$10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
25091 10/02/2026 11/06/2026 2027-00000156 $100.00
Less Prepayment $0.00
Total Due-* $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
W
Waterloo Fire Rescue �•{
til
) Inspection Report 425 E.3rd Street
Get Air-3729 University AVE,BLDG 3729 University Ave,Waterloo IA 50701
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
0912812026 Annual Inspection(1Yr) a r',It I 4 (x 935
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A N/A N/A
Other Inspectors
NIA
SUMMARY OF INSPECTION
036 029 ® 24
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN
31/04/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-09/28/2026 @ 15:21
Fire extinguishers due annually serviced October 2026.
BRAD BALDWIN-09/28/2026 @ 15:21
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
BRAD BALDWIN-09/28/2026 @ 15:21
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224
BRAD BALDWIN-09/28/2026 @ 15:21
•$100 annual inspection fee
SIGNATURES
Contact signature Inspector signature
No signature --1I(
Report completededpost ostinspection
Business Manager-2026 Date: BRAD BALDWIN 10/01/2026
CHECKLISTS
GENERATED ON 10/1/2e, 12:39 PM 1 OF 18
Means of Egress
Status Code Description
Fail 1032.2-Reliability.
Required exit accesses,exits and exit discharges shall be Location:Upstairs office
continuously maintained free from obstructions or Comments:Remove all obstructions on stairs and in exit path from
impediments to full instant use in the case of fire or other upper level space.
emergency where the building area served by the means of
egress is occupied.An exit or exit passageway shall not be
used for any purpose that interferes with a means of egress.
4i
se ' . Al
it ', '
.
GENERATED ON 10/1/26, 12:34 PM 2 OF 18
Additional Codes
Status Code Description
Fail 1013.1-Where required.
Exits and exit access doors shall be marked by an approved Location:Break room-upper level
exit sign readily visible from any direction of egress travel Comments:Remove storage from upper shelf obstructing view of exit
The path of egress travel to exits and within exits shall be sign and egress lights.Maintain no storage on upper shelf.
marked by readily visible exit signs to clearly indicate the
direction of egress travel in cases where the exit or the path
of egress travel is not immediately visible to the occupants.
Intervening means of egress doors within exits shall be
marked by exit signs.Exit sign placement shall be such that
any point in an exit access corridor or exit passageway is
within 100 feet(30 480 mm)or the listed viewing distance of
the sign,whichever is less,from the nearest visible exit sign.
Exceptions:1.Exit signs are not required in rooms or areas
that require only one exit or exit access.2.Main exterior exit
doors or gates that are obviously and clearly identifiable as
exits need not have exit signs where approved by the fire
code official.3.Exit signs are not required in occupancies in
Group U and individual sleeping units or dwelling units in
Group R-1,R-2 or R-3.4.Exit signs are not required in
dayrooms,sleeping rooms or dormitories in occupancies in
Group 1-3.5.In occupancies in Groups A-4 and A-5,exit signs
are not required on the seating side of vomitories or openings
into seating areas where exit signs are provided in the
concourse that are readily apparent from the vomitories.
Egress lighting is provided to identify each vomitory or
opening within the seating area in an emergency.
,J
I
Fail 603.1-General.
0 Electrical equipment,wiring and systems required by this Location:Tables&eating area
code or the International Building Code shall be installed, Comments:Food warmers(2)and mini fridges(2)shall be removed
used and maintained in accordance with NFPA 70 and from plugged to power strips.Appliances including motors or
Sections 603.2 through 603.10. heating elements shall plug directly to a permanent outlet.
GENERATED ON 10/1/20, 12:39 PM 3 OF 18
Fail 901.6-Inspection,testing and maintenance.
Fire detection and alarm systems,emergency alarm systems, Location:Above vertical trampolines
gas detection systems,fire-extinguishing systems, Comments:Replace missing sprinkler head protective cage
mechanical smoke exhaust systems and smoke and heat
vents protection and life safety systems shall be maintained
In an operative condition at all times,and shall be replaced or
repaired where defective.Nonrequired fire protection and life
safety systems and equipment shall be inspected,tested and
maintained or removed in accordance with Section 901.8.
Fail 907.8-Inspection,testing and maintenance.
The maintenance and testing schedules and procedures for Location:Break room-upper level
fire alarm and fire detection systems shall be in accordance Comments:Fire alarm device shall be mounted to wall to avoid
with Sections 907.8.1 through 907,8.4 and NFPA 72.Records hanging by wires.
of inspection,testing and maintenance shall be maintained.
GENERATED ON 1®/1/26, 12:39 PM 4 OF 18
Fail 907.8.4-Inspection,testing and maintenance.
The building owner shall be responsible to maintain the fire Location:Party Room#1
and life safety systems in an operable condition at all times. Comments:Missing fire alarm device shall be replaced by licensed
Service personnel shall meet the qualification requirements contractor.Provide contractors invoice to show inspector.
of NFPA 72 for Inspection,testing and maintenance of such
systems.Records of inspection,testing and maintenance
shall be maintained.
i
a'. . 7
t
,,:_.,:
:,. 4
,:,
,:,,
,,,
, t
,. ,
Emergency Equipment
Status Code Description
Fail 1203.4.3-Records.
Records of the inspection,testing and maintenance of Location:Entire business space
emergency and standby power systems shall include the date Comments:Provide documentation of testing all emergency egress
of service,name of the servicing technician,a summary of lighting and exit signage in space including repairs completed to
conditions noted and a detailed description of any conditions non-functioning devices.Email document to inspector including
requiring correction and what corrective action was taken. signed and dated of responsible person.
Such records shall be maintained.
GENERATED ON 10/1/28, 12:39 PM 5 OF 18
Fire Sprinkler System
Status Code Description
Fail 5.2.1.1.5-Missing escutcheons
Escutcheons and coverplates for recessed,flush,and Location:Rear(south)exit hallway
concealed sprinklers shall be replaced if found missing Comments:Sprinkler head escutcheon installed upside down shall
during the inspection, be corrected.Gaps surrounding escutcheons shall be properly
repaired to maintain protection of ceiling.
C2
Fail 903.3.3-Obstructed locations.
Automatic sprinklers shall be installed with regard to Location:Women's bathroom
obstructions that will delay activation or obstruct the water Comments:Remove dust/debris from(2)sprinkler heads.
distribution pattern and shall be in accordance with the
applicable automatic sprinkler system standard that is being
used.Automatic sprinklers shall be installed in or under
covered kiosks,displays,booths,concession stands or
equipment that exceeds 4 feet(1219 mm)in width.Not less
than a 3-foot(914 mm)clearance shall be maintained between
automatic sprinklers and the top of piles of combustible
fibers.Exception:Kitchen equipment under exhaust hoods
protected with a fire-extinguishing system in accordance with
Section 904.
Fail 903.3.3-Obstructed locations.
Automatic sprinklers shall be installed with regard to Location:South wall-above"vertical trampolines"
obstructions that will delay activation or obstruct the water Comments:Remove dust/debris from sprinkler heads
distribution pattern and shall be in accordance with the
applicable automatic sprinkler system standard that is being
used.Automatic sprinklers shall be installed in or under
covered kiosks,displays,booths,concession stands or
equipment that exceeds 4 feet(1219 mm)in width.Not less
than a 3-foot(914 mm)clearance shall be maintained between
automatic sprinklers and the top of piles of combustible
fibers.Exception:Kitchen equipment under exhaust hoods
protected with a fire-extinguishing system in accordance with
Section 904.
GENERATED ON 10/1/26, 12:30 PM 6 OF 18
Fire Service Features
Status Code Description
Fail 509.2•Equipment access.
Approved access shall be provided and maintained for all fire Location:Rear(south)exit hallway
protection system equipment to permit Immediate safe Comments:Provide door handle on interior door on hallway side to
operation and maintenance of such equipment.Storage,trash access Into trampoline space,currently missing handle.
and other materials or objects shall not be placed or kept in
such a manner that would prevent such equipment from
being readily accessible.
Fail 509.2•Equipment access.
Approved access shall be provided and maintained for all fire Location:Electric panel room•through Party Room 1
protection system equipment to permit immediate safe Comments:Fire fighters shall have clear access to utilities in case of
operation and maintenance of such equipment.Storage,trash emergency,currently door to electric room requires special
and other materials or objects shall not be placed or kept in knowledge of key pad door hardware.Door shall either remain
such a manner that would prevent such equipment from unlocked or changed to key lock access with copy of that key in
being readily accessible. Knox Box.
GENERATED ON 10/1/26, 12:39 PM 7 OF 18
Electrical Safety
Code Description
Fail 603.2-Abatement of unsafe conditions and electrical
hazards. Location:Foam Pit
Identified electrical hazards shall be abated.Identified Comments:Remove accumulation of dust behind TV around supply
hazardous electrical conditions in permanent wiring shall be cord and outlet connection.
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
•
el\4,,
,; A.
GENERATED ON 10/1/26, 12:39 PM 8 OF 18
Fail 603.2-Abatement of unsafe conditions and electrical
hazards. Location:Above play equipment(see photo attached)
Identified electrical hazards shall be abated.Identified Comments:Remove green multi-plug adapter above play equipment
hazardous electrical conditions in permanent wiring shall be in photo attached,also noted broken plug in adapter,
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
/, �t�
. A M.;.
-r.'3,, t�1'j z41 1 1 V: t '
„I., tti/10%11 it .
t a• ra
�'
r
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
Open junction boxes and open-wiring splices shall be Location:"Restricted Area"through Party Room#1
prohibited.Approved covers shall be provided for all switch
and electrical outlet boxes. Comments:Open wire connections shall be properly capped and
contained in a box with cover.Boxes missing covers shall be
i- li,
corrected.
. :.,, . ,
s CUPS -�',�T.
.v f:.:
'.,:"::-.',.:
Ala
• • ,.
Jr
. ti ; .
- 4
y M�I'
GENERATED ON 10/1/28, 12:39 PM 9 OF 18
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
Open junction boxes and open-wiring splices shall be Location:"Restricted Area"through Party Room#1
prohibited.Approved covers shall be provided for all switch Comments:Install knockout plug in opening in bottom of box
and electrical outlet boxes.
4110,1*
3 *a,
* `-'
Fail 603.4-Working space and clearancesclearance.
A working space of not Working space around electrical Location:"Restricted Area"through Party Room#1-Electric panels
equipment shall be provided in accordance with Section Comments:Relocate storage withing 36 inches of electric panels and
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or maintain clear unobstructed path to utilities for firefighters at all
less,and Section 110.33 of NFPA 70 for electrical equipment times,currently path unobstructed from door to panels.
rated over 1,000 volts.The minimum required working space
shall be not less than 30 inches(762 mm)in width,36 inches
(914 mm)in depth and 78 inches(1981 mm)in height shall be
providedin front of electrical service equipment.Where the
electrical service equipment is wider than 30 inches(762
mm),the minimum working space shall be not less than the
width of the equipment.Storage of materials shall not be
located within the designated working space.Exceptions:1.
Where other dimensions are required or allowed by NFPA 70.
2.Access openings into attics or under-floor areas that
provide a minimum clear opening of 22 inches(559 mm)by 30
inches(762 mm).
Fail 603.4.1-Labeling.
Doors into electrical control panel rooms shall be marked Location:Party Room#1-Electric Room
with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide permanent signage on door indicating
ROOM"or similar approved wording.The disconnecting "ELECTRIC ROOM"or other approved wording,laminated paper will
means for each service,feeder or branch circuit originating not be accepted.
on a switchboard or panelboard shall be legibly and durably
marked to indicate its purpose unless such purpose is clearly
evident.Where buildings or structures are supplied by more
than one power source,markings shall be provided at each
service equipment location and at all interconnected electric
power production sources identifying all electric power
sources at the premises in accordance with NFPA 70.
10 OF 18
GENERATED ON 10/1/20, 12:39 PM
Fail 603.5-Relocatable power taps and current taps,Muitiplug
adapters. Location:Above"Toy Locker"claw machine
Multiplug adapters,such as cube adapters,unfused plug Comments:Remove green multi plug adapter below ceiling trusses.
strips or any other device not complying with NFPA 70 shall May replace with properly supported power strip with manual reset
be prohibited.The construction and use of current taps and for low wattage electronics only.
relocatable taps shall be in accordance with NFPA 70 and this
code.
Fail 603.6-Extension cords.
Extension cords and flexible cordsshali not be a substitute Location:Front vestibule
for permanent wiring and shall be listed and labeled in Comments:White extension cord extending above drop ceiling shall
accordance with UL 817.Extension cords and flexible be removed.
cordsshall not be affixed to structures,extended through
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Office-upper level
for permanent wiring and shall be listed and labeled in Comments:Remove green multi-plug adapter and orange extension
accordance with UL 817.Extension cords and flexible cord,currently extending through window.Flexible supply cords
cordsshall not be affixed to structures,extended through shall not extend through doorways,or windows to avoid
walls,ceilings or floors,or under doors or floor coverings, y pinching
hazard.
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
dir
•
•
GENERATED ON 10/1/20, 12:39 PM 11 OF 18
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location."Restricted Area"through Party Room#1
for permanent wiring and shall be listed and labeled in Comments:Multiple extension cords noted to fridges and freezers
accordance with UL 817.Extension cords and flexible shall be removed.Also,appliances including motors or heating
cordsshall not be affixed to structures,extended through elements shall plug directly to a permanent outlet.If adding new
walls,ceilings or floors,or under doors or floor coverings, outlet,a licensed electrical contractor shall obtain permit and
nor shall such cords be subject to environmental damage or inspection.
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Ittry
12 OF 18
GENERATED ON 10/1/26, 12:39 PM
Fire Resistant Construction Maintenance
Status Cc cli Description
Fail 704.1-Maintaining protection.
Where required when the building was originally constructed, Location:Front vestibule
materials and systems used to protect joints and voids in the Comments:Missing or damaged ceiling tiles shall be replaced.
following locations shall be maintained.The materials and
systems shall be securely attached to or bonded to the
adjacent construction,without openings visible through the
construction.1.Joints in or between fire-resistance-rated
walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall.4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall.5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall.6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall.7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly.Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed.Where the system design number is known,the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Fail 704.1-Maintaining protection.
QWhere required when the building was originally constructed, Location:Men's bathroom closet
materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tiles.
following locations shall be maintained.The materials and
systems shall be securely attached to or bonded to the
adjacent construction,without openings visible through the
construction.1.Joints in or between fire-resistance-rated
walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall.4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall.5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall.6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall.7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly.Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed.Where the system design number is known,the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
GENERATED ON 10/1/20, 12;39 PM 13 OF 18
Fail 704.1-Maintaining protection.
Where required when the building was originally constructed, Location:Break room-upper level
materials and systems used to protect joints and voids in the Comments:Gaps around sprinkler escutcheons(2)shall be corrected
following locations shall be maintained.The materials and to avoid heat escaping above ceiling,possibly slowing activation of
systems shall be securely attached to or bonded to the sprinklers.Ceiling tile shall be replaced without gaps,fire caulked or
adjacent construction,without openings visible through the larger escutcheon provided by licensed sprinkler contractor.
construction.1.Joints in or between fire-resistance-rated
walls,floors or floorlceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall.4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall.5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall.6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall.7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly.Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed.Where the system design number is known,the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
•
•
14 OF 18
GENERATED ON 10/1/20, 12:39 PM
Fail 704.1-Maintaining protection.
Where required when the building was originally constructed, Location:Upper level-small closet above stairs
materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tiles.
following locations shall be maintained.The materials and
systems shall be securely attached to or bonded to the
adjacent construction,without openings visible through the
construction.1.3oints in or between fire-resistance-rated
walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall.4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall.5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall.6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall.7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly.Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed.Where the system design number is known,the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Fail 704.1-Maintaining protection.
Where required when the building was originally constructed, Location:Party Room#1
materials and systems used to protect joints and voids in the Comments:Gaps around sprinkler escutcheons(2)shall be corrected
following locations shall be maintained.The materials and to avoid heat escaping above ceiling,possibly slowing activation of
systems shall be securely attached to or bonded to the sprinklers.Ceiling tile shall be replaced without gaps,fire caulked or
adjacent construction,without openings visible through the larger escutcheon provided by licensed sprinkler contractor.
construction.1.Joints in or between fire-resistance-rated
walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall.4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall.5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall.6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall.7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly.Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed.Where the system design number is known,the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
GENERATED ON 1O/1/26, 12:39 PM 15 OF 18
Portable Fire Extingusihers
status Cod; Description
Fail 906.2-General requirements.
Portable fire extinguishers shall be selected,installed and Location:Roof access
maintained in accordance with this section and NFPA 10. Comments:Inspector not able to access upper level,staff should
Exceptions:1.The distance of travel to reach an extinguisher provide inspector access during next re-inspection
shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device,provided that all of the
following conditions are met:2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal.2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10.3.In Group 1-3,portable fire
extinguishers shall be permitted to be located at staff
locations.
GENERATED ON 10/1/20, 12:39 PM 16 OF 18
Fail 906.2-General requirements.
Portable fire extinguishers shall be selected,installed and Location:Rear(south)exit hallway
maintained in accordance with this section and NFPA 10. Comments:Provide missing annually serviced extinguisher on wall
Exceptions:1.The distance of travel to reach an extinguisher bracket
shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device,provided that all of the
following conditions are met:2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal.2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10.3.In Group 1-3,portable fire
extinguishers shall be permitted to be located at staff
locations.