COMMERCIAL FIRE INSPECTION - 708 JEFFERSON ST-09/29/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
25092 10/02/2026 11/06/2026 2027-00000160 $80.00
Less Prepayment $0.00
Total Due -* $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
„,,d Waterloo Fire Rescue
Inspection Report 425 E.3rd Street
Ikes Pub-708 Jefferson ST,BLDG 708 Jefferson St,Waterloo IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Numbei
09129/2026 Annual Inspection(1Yr) cgt qa (4,g0°D 24451
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A N/A N/A
Other inspectors
N/A
SUMMARY OF INSPECTION
044 9 ® 24
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN
10/22/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-0913012026 @ 07:43
Extinguishers due annually serviced January 2027
BRAD BALDWIN-09130/2026 @ 07:42
Annual sprinkler system inspection due 10/22126
BRAD BALDWIN-0913012026 @ 07:42
Annual fire alarm inspection due 12/2126.
BRAD BALDWIN-09130/2026 @ 07:42
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224
BRAD BALDWIN-09130/2026 @ 07:41
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and S200 for all subsequent re-inspections.
BRAD BALDWIN-09130/2026 @ 07:41
•Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-09130/2026 @ 07:41
•$80 annual inspection fee
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
GENERATED ON 10/1/26, 7:34 AM 1 OF 6
Lindsay Hoffer•2026 Date:
CHECKLISTS
Means of Egress BRAD BALDWIN 1010112026
Status Code Description
Fall 1004.9-Posting of occupant load.
lh) Every room or space that is an assembly occupancy shall Location:Occupant load
have the occupant load of the room or space posted in a Comments:Do not recall seeing occupant load sign during 9/29126
conspicuous place,near the main exit or exit access doorway inspection.Provide sign installed or have inspector calculate
from the room or space,for the intended configurations. occupant load and create new sign.
Posted signs shall be of an approved legible permanent
design and shall be maintained by the owner or the owner's
authorized agent.
GENERATED ON 10/1/26, 7:34 AN 2 OF 6
Additional Codes
Stave Code Description
Fail 5303,5.3-Securing compressed gas containers,cylinders
and tanks. Location:Top of stairs and basement
Compressed gas containers,cylinders and tanks shall be Comments:All tanks shall be chained or securely strapped to avoid
secured to prevent falling caused by contact,vibration or tip-over hazard.
seismic activity.Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers,cylinders and tanks to a fixed object
with one or more restraints.2.Securing containers,cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers,cylinders or tanks.
3.Nesting of compressed gas containers,cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public.Nesting shall be allowed
provided that the nested containers,cylinders or tanks,if
dislodged,do not obstruct the required means of egress.
4.Securing of compressed gas containers,cylinders and
tanks to or within a rack,framework,cabinet or similar
assembly designed for such use.Exception:Compressed gas
containers,cylinders and tanks in the process of
examination,filling,transport or servicing.
"-—,. \4 4,,, :;.1.1 ' I
\ , . . _, :
i \t)
• s;u
Fail 807.3-Acceptance criteria and reports.
Where required to exhibit improved fire performance, Location:Top of stairs
curtains,draperies,fabric hangings and other similar Comments:Provide documents that curtains meet required flame
combustible decorative materials suspended from walls or performance or remove.
ceilings shall be tested by an approved agency and meet the
flame propagation performance criteria of Test Method 1 or
Test Method 2,as appropriate,of NFPA 701 or exhibit a
maximum rate of heat release of 100 kW when tested in
accordance with NFPA 289,using the 20 kW ignition source.
Reports of test results shall be prepared in accordance with
the test method used and furnished to the fire code official
upon request.
GENERATED ON 10/1/2e, 7:34 AM 2 OF 6
Electrical Safety
Status Code Description
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
OOpen junction boxes and open-wiring splices shall be Location:Next to casino games
prohibited.Approved covers shall be provided for all switch Comments:Install missing outlet and light switch covers
and electrical outlet boxes.
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
Open junction boxes and open-wiring splices shall be Location:Bathrooms and near bar TV's
prohibited.Approved covers shall be provided for all switch Comments:Replace missing outlet covers
and electrical outlet boxes.
Fail 603.4-Working space and clearancesclearance.
A working space of not Working space around electrical Location:Basement-Electric panels
equipment shall be provided in accordance with Section Comments:Remove storage within 36"of electric panels and
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or maintain clear unobstructed path to panels for fire fighters at all
less,and Section 110.33 of NFPA 70 for electrical equipment times.
rated over 1,000 volts.The minimum required working space
shall be not less than 30 inches(762 mm)in width,36 inches
(914 mm)in depth and 78 inches(1981 mm)in height shall be
providedin front of electrical service equipment.Where the
electrical service equipment is wider than 30 inches(762
mm),the minimum working space shall be not less than the
width of the equipment.Storage of materials shall not be
located within the designated working space.Exceptions:1.
Where other dimensions are required or allowed by NFPA 70.
2.Access openings into attics or under-floor areas that
provide a minimum clear opening of 22 inches(559 mm)by 30
inches(762 mm).
Fail 603.5.2-Application and usePower supply.
ORelocatable power taps and current taps shall be directly Location:Bar-behind chest cooler
connected to a permanently installed receptacle.Exceptions: Comments:Remove power strips daisy chained(plugged from one to
1.Where approved for use in a Group A occupancy or in a another).Each power strip shall plug directly to a wall outlet.Power
meeting room in a Group B occupancy,not more than five strips shall also be properly supported to avoid hanging by wires.
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment.2.Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
Fail 603.5.2-Application and usePower supply.
ORelocatable power taps and current taps shall be directly Location:Below bar/register counter
connected to a permanently installed receptacle.Exceptions: Comments:Properly support power strips to avoid currently hanging
1.Where approved for use in a Group A occupancy or in a by wires.
meeting room in a Group B occupancy,not more than five
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment.2.Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
GENERATED ON 10/1/26, 7:34 AM 4 OF 6
Portable Fire Extingusihers
Status Code Description
Fail 906.7•Hangers and brackets.
Hand-held portable fire extinguishers,not housed In cabinets, Comments:Install extinguisher on wall bracket from 4"to 5'above
shall be installed on the hangers or brackets supplied. floor.If installing in location discussed during 9/29/26 inspection,
Hangers or brackets shall be securely anchored to the signage shall be permanently installed to indicate location.
mounting surface in accordance with the manufacturer's
installation instructions.
GENERATED ON 10/1/2e, 7:34 AM 5 OF 6