Loading...
HomeMy WebLinkAboutHY-VEE WINE & SPIRITS-2126 KIMBALL AVE OF W A PF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 10/02/2026 11/06/2026 2027-00000161 $80.00 o .,aar.$•. ' A O • U 1 O 11 • " IF S 711'., Customer#: 12084 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HY-VEE WINE& SPIRITS 715 Mulberry St 2126 KIMBALL AV WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION -2126 KIMBALL AVE-09/18/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12084 10/02/2026 11/06/2026 2027-00000161 $80.00 Less Prepayment $0.00 Total Due--> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street d* Hy-Vee Wine&Spirits#1-2126 Kimball AVE,BLDG 2126 Kimball Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type f Inspection Number � 09/18/2026 Annual Inspection(1Yr) I)(, 4 i 18960 Lead Inspector Shift Station Unit BRAD BALDWIN N/A N/A N/A Other Inspectors NIA SUMMARY OF INSPECTION 0 28 0 8 ® 39 Passed codes Failed codes N/A cc NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 10109/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09/18/2026 @ 14:05 Storage obstructing electric panels in back room removed on-site during 9118/26 inspection. BRAD BALDWIN-09/18/2026 @ 13:50 Fire extinguishers due annually serviced in March 2027 BRAD BALDWIN-09118/2026 @ 13:49 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and S200 for all subsequent re-inspections. BRAD BALDWIN-09/18/2026 @ 13:49 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-09118/2026 @ 13:49 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-09118/2026 @ 13:47 •$80 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completedeelpost stinspection CJ McBreen District Store Director 2026 Date: BRAD BALDWIN 09/18/2026 GENERATED ON 9/18/26, 2:24 PM 1 OF 6 CHECKLISTS Means of Egress St lids Code Description Fail 1010.1.3-Door opening force Forces to unlatch and open doors. Location:Back exit The force for pushing or pulling open interior swinging Comments:Repair or replace exit door that failed to open with less egress doors,other than fire doors,shall not exceed 5 than 15 lbs of force.Replacement of door requires permit and pounds(22 N).These forces do not apply to the force inspection obtained. required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Back exit hallway continuously maintained free from obstructions or Comments:Remove storage in hallway,maintain clear path of egress impediments to full instant use in the case of fire or other to exit at all times. emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. [ #� Aix • R.R GENERATED ON 9/18/26, 2:24 PM 2 OF 6 Additional Codes 54atu5 Cede Description Fail 603.1•General. Electrical equipment,wiring and systems required by this Location:"Red Bull"&"Monster"fridges code or the international Building Code shall be installed, Comments:Appliances including motors or heating elements shall used and maintained in accordance with NFPA 70 and plug directly to a permanent outlet.Remove fridges plugged to power Sections 603.2 through 603.10. strip. GENERATED ON 9/18/28, 2:24 PM 3 OF 6 V - _ Electrical Safety Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Above NA beers and Carbliss prohibited.Approved covers shall be provided for all switch Comments:Open wire connections missing covers shall be and electrical outlet boxes. corrected. 4 • tkr , Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Above coolers next to"Mixers"shelving connected to a permanently installed receptacle.Exceptions: Comments:Power strip shall plug directly to a permanent outlet, 1.Where approved for use in a Group A occupancy or in a remove power strip plugged to extension cord. meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Behind"Red Bull"&"Monster"fridges ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip to avoid hanging by wires. to environmental or physical damage. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Behind"Mixers"shelving for permanent wiring and shall be listed and labeled in Comments:Remove green extension cord accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 9/18/28, 2:24 PR 4 OF 6 Fall 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:TV near front exit for permanent wiring and shall be listed and labeled In Comments:Remove extension cords above ceiling plugged to TV. accordance with UL 817.Extension cords and flexible Extension cords shall not be used as permanent wiring and shall cordsshall not be affixed to structures,extended through flexible supply cords shall not extend through concealed spaces. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical Impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 0/18/26, 2:24 PM 5 OF 6 o Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/18/28, 2:24 PN 6 OF 6