Loading...
HomeMy WebLinkAboutKWIK STAR #380-506 W. 9TH ST O WA rF INVOICE DATE DUE DATE INVOICE# TOTAL DUE A .�t 10/02/2026 11/06/2026 2027-00000162 $80.00 u .aiv,. !� O • I II 11 11 II • O Customer#: 7635 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable KWIK STAR#380 715 Mulberry St 1626 OAK ST WATERLOO, IA 50703 LA CROSS, WI 54602 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 506 W 9TH ST-09/18/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 7635 10/02/2026 11/06/2026 2027-00000162 $80.00 Less Prepayment $0.00 Total Due —> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue slag Inspection Report 425 E.3rd Street Kwik Star#380-506 W 9th ST,BLDG 506 W 9th St,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type � Inspection Number 0911812026 Annual Inspection(1Yr) 7LF: J $rt. 19193 Lead Inspector Shift Station Unit BRAD BALDWIN NIA N/A N/A Otr er Inspecrors N/A SUMMARY OF INSPECTION 0 43 10 ® 26 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 1011412026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09/22/2026 @ 10:36 Fire extinguishers due annually serviced March 2027 BRAD BALDWIN-09/22/2026 @ 10:36 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-09122/2026 @ 10:36 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-0912212026 @ 10:35 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)•Cell:319-230-1224 BRAD BALDWIN-09/2212026 @ 10:35 •$80 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completedeelpost ostinspection Alicia 2025-store leader Date: BRAD BALDWIN 09/22/2026 CHECKLISTS GENERATED ON 9/22/28, 10:38 AM 1 OF 6 Additional Codes Status Code Description Fail 2305.2•Equipment maintenance and Inspection. Motor fuel-dispensing facility equipment shall be maintained Location:Fuel pump 1 In proper working order at all times in accordance with Comments:Necessary repairs shall be made to pumps out of service. Sections 2305.2.1 through 2305.2.5. Fail 2305.2-Equipment maintenance and inspection. Motor fuel-dispensing facility equipment shall be maintained Location:Fuel pump 4 in proper working order at all times in accordance with Comments:Necessary repairs shall be made to 87 Octane pump out Sections 2305.2.1 through 2305,2.5. of service. Fail 2305.2-Equipment maintenance and inspection. Motor fuel-dispensing facility equipment shall be maintained Location:Fuel pump 2 in proper working order at all times in accordance with Comments:Necessary repairs shall be made to 88 Octane pump out Sections 2305.2.1 through 2305.2.5. of service. Fail 2305.2-Equipment maintenance and inspection. Motor fuel-dispensing facility equipment shall be maintained Location:Fuel pump 5 in proper working order at all times in accordance with Comments:Necessary repairs shall be made to 88 Octane pump out Sections 2305.2.1 through 2305.2.5. of service. Fire Service Features St' Cad. Description Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:Electric room near CarWash protection system equipment to permit immediate safe Comments:Remove obstructions within 36"of electric panels and operation and maintenance of such equipment.Storage,trash maintain clear ready access to panels at all times and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. GENERATED ON 9/22/2G, 1,3;33 AN 2 OF 6 Electrical Safety Status Code Description Fall 603.2.2-Unapproved conditlonsOpen electrical terminations. Ox Open junction boxes and open-wiring splices shall be Location:Near main exit-Behind"Frozen Treats"freezer prohibited.Approved covers shall be provided for all switch Comments:Replace missing outlet cover and electrical outlet boxes. Fail 603.4-Working space and clearancesclearance. 0 A working space of not Working space around electrical Location:Back storage equipment shall be provided in accordance with Section Comments:Remove all storage from within 36"of electric panels. 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or Suggest marking floor where storage is prohibited. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). II ' 7 1:6 1i) t d le' r1*fa , ' i GENERATED ON 9/22/26, 10:39 AM 3 OF 6 • Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. Ox Portable fire extinguishers shall be selected,Installed and Location:Front vestibule maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguisher,currently past Exceptions:1.The distance of travel to reach an extinguisher due for service shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Kitchen maintained in accordance with this section and NFPA 10. Comments:Class K extinguisher service tag missing date of service Exceptions:1.The distance of travel to reach an extinguisher markings. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 0/22/26, 10;38 AM 4 OF 6 Fail 906.6.Unobstructed and unobscured, O Portable fire extinguishers shall not be obstructed or Location:Sack storage area obscured from view.In rooms or areas in which visual Comments:Remove obstructions to extinguisher or relocate obstruction cannot be completely avoided,means shall be extinguisher to an approved conspicuous location. provided to indicate the locations of extinguishers. , J M _A. ^i 1 , GENERATED ON 9/22/28, 10:38 AM 5 OF 6 rg Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A 880.00 Invoice Number Check Number Transaction Number NIA N/A N/A GENERATED ON 9/22/26, 10:38 AM 6 OF 6