Loading...
HomeMy WebLinkAboutSTARBECK'S SMOKEHOUSE-250 WESTFIELD AVE OF W q rF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 'cle 10/02/2026 11/06/2026 2027-00000164 $80.00 • '11 ■u i 111I I • ) *-= T 0 4S it'll' Customer#: 24391 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable STARBECK'S SMOKEHOUSE 715 Mulberry St 250 WESTFIELD AVE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION -250 WESTFIELD AVE-09/17/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24391 10/02/2026 11/06/2026 2027-00000164 $80.00 Less Prepayment $0.00 Total Due— $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street Starbeck's Smokehouse-250 Westfield AVE,BLDG 250 Westfield Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 09117/2026 Annual Inspection(1Yr) a43c1 18802 Lead Inspector Shift Station ��- Unit BRAD BALDWIN N/A NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION 053 022 ® 10 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 1010912026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09/18/2026 @ 09:10 Fire extinguishers due annually serviced in April 2027 BRAD BALDWIN-09/18/2026 @ 08:56 Kitchen hood cleaning due 11118/26 BRAD BALDWIN-09118/2026 @ 08:56 Kitchen hood suppression due for inspection on 10/27/26 BRAD BALDWIN-09/18/2026 @ 08:54 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-0911812026 @ 08:54 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-09/18/2026 @ 08:54 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-09/18/2026 @ 08:54 •$80 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 0/18/26, 9:42 AM 1 OF 11 Corbin Burr-2026 Date: I-qM, CHECKLISTS Emergency Equipment BRAD BALDWIN 0911812026 Status Code Description Fall 1203.2.15-Means of egress illumination. OEmergency power shall be provided for means of egress Location:Kitchen exit illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Storage on shelving shall be relocated to avoid obstructing view of exit sign. IP rI ..-..,,,s.,,..1: ,Y . i .._______ Fail 1203.2.6-Exit signs. JEmergency power shall be provided for exit signs as required Location:East exit near patio seating in Section 1013.6.3.The system shall be capable of powering Comments:Exit sign turned wrong direction,exit sign shall face the required load for a duration of not less than 90 minutes. dining area to direct to exit door. Fail 1203.4.3-Records. Records of the inspection,testing and maintenance of Comments:All exit signage and emergency egress lighting shall be emergency and standby power systems shall include the date tested and repaired if necessary to maintain working properly. of service,name of the servicing technician,a summary of Provide documentation of testing to inspector. conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. 1 GENERATED ON 9/18/26, 9:42 AN 2 OF 11 Fire Sprinkler System Status Code Description Fail 4.9-Support of nonsprinkler system components 1`; Sprinkler system components shall not be used to support Location:East dining area non-sprinkler system components unless expressly permitted Comments:Remove signs supported by sprinkler system. by NFPA 13. 11' Ir -r R _�- 1 F c p } Rath ~_ E Va. Feed t '„„%ft.. ,'-:"„Agli AL ' ` \_.rr... -- y - GENERATED ON 9/18/2G, 0:42 AM 3 OF 11 Fire Service Features Status Code Description Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:East exit near patio seating protection system equipment to permit immediate safe Comments:Remove obstructions to fire alarm pull station,maintain operation and maintenance of such equipment.Storage,trash clear line of sight to pull station at all times. and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. • F.! Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:Fire department connection-North Exterior protection system equipment to permit immediate safe Comments:Remove all storage from area as stated on signage. operation and maintenance of such equipment.Storage,trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 1 (i EEt, 9r t i i y S V. GENERATED ON 9/10/26, 0:42 MI 4 OF 11 Additional Codes Status Code Description Fail 5303.5,3-Securing compressed gas containers,cylinders and tanks. Location:CO2 closet behind soda fountain machine Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders tightly with chain to secured to prevent falling caused by contact,vibration or avoid tip over.Currently tanks are loosely chained and one tank seismic activity,Securing of compressed gas containers, unchained. cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Closet behind soda fountain machine code or the International Building Code shall be installed, Comments:Appliances including motors or heating elements shall used and maintained in accordance with NFPA 70 and plug directly to an outlet,currently plugged to a power strip.Remove Sections 603.2 through 603.10. pump from power strip,if adding a new outlet,a licensed electrician shall obtain permit and inspection Fail 603.1.1-Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, Location:Outdoor patio wiring,devices and appliances shall be tested;and listed by Comments:Remove outlet improperly wired to create extension cord. an approved agency and labeled;and installed,used and Cord and outlet shall be permanently removed from building. maintained in accordance with NFPA 70 and all instructions included as part of such listing. ,, ` tO ,V10 i . 7 y /J�, r y. i . .._ 4 .?s,/,,.. GENERATED ON 0/1N/25, 0:42 AM 5 OF 11 Electrical Safety St;ttus Code Description Fall 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Ceiling above table#40 prohibited.Approved covers shall be provided for all switch Comments:Open wire connection shall be properly capped and and electrical outlet boxes. contained in box with cover. /).' J rr to f, }.< / '1/4 y s �4, Ais Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Ceiling above table#42 prohibited.Approved covers shall be provided for all switch and electrical outlet boxes. Comments:Provide missing electrical box cover GENERATED ON 9/18/26, 0:42 AM 6 OF 11. Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:East end of bar connected to a permanently installed receptacle.Exceptions: Comments:Remove power strip plugged to extension cord,power 1.Where approved for use in a Group A occupancy or in a strips shall plug directly to an outlet. meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. o al ,t ¢ 1111:-.'.1111:1111::: 7 OF 11 GENERATED ON 9/18/26, 9:42 AM Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Kitchen-below ordering counter connected to a permanently installed receptacle.Exceptions: Comments:Power strip currently plugged to extension cord,power 1.Where approved for use In a Group A occupancy or In a strips shall plug directly to an outlet.Extension cord shall be meeting room in a Group B occupancy,not more than five removed. relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. i v I. r► ...,... ,,,,4_ . , %. __.... ,„ ... . ....,- ., sfircjor r - 4,- - ._ 1 .,_ ,r. tl, ,„ 4.s. ..„ I _ 044 : __. /4 ., -/,* :: ,- 0 . _ ..-.,:„. ..„ _ I'-i!, ,, ,, 1--- , , . Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:East end of bar-Below"Shiner"sign ceilings,floors,under doors or floor coverings,or be subject Comments:Power stripshall be properly supported to environmental or physical damage. p p Y to avoid hanging by wires. Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Kitchen office ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip below IT rack currently to environmental or physical damage. hanging by wires. GENERATED ON 9/18/26, 9:42 AM 8 OF 11 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:East end of bar-Below"Miller Lite"neon sign for permanent wiring and shall be listed and labeled in Comments:Extension cords shall not be used as permanent wiring, accordance with UL 817.Extension cords and flexible remove multi-plug extension cord. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact,Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. wri, _ _ I _ ,, , ! t ; '.„ ---'?'" F. r t � t IS it , 4F kr i1. f a Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:"Founders"window sign near bar for permanent wiring and shall be listed and labeled in Comments:Extension cords shall not be used as permanent wiring, accordance with UL 817.Extension cords and flexible remove sign plugged to extension cord. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Closet behind soda fountain machine for permanent wiring and shall be listed and labeled in Comments:Extension cords shall not be used as permanent wiring. accordance with UL 817.Extension cords and flexible Remove orange extension cord to"Beverage Control System".If cordsshall not be affixed to structures,extended through adding a new outlet,a licensed electrical contractor shall obtain a walls,ceilings or floors,or under doors or floor coverings, permit and inspection.Also,provide inspector information of cords nor shall such cords be subject to environmental damage or extending through wall physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 9/18/28, 9:42 AM 9 OF 11 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Soda fountain machine for permanent wiring and shall be listed and labeled In Comments:Remove green extension cord behind machine. accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Bar TV near"Rainbow"sign for permanent wiring and shall be listed and labeled in Comments:Remove TV from plugged to extension cord. accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System C: Ole Code Description Fail 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood filters appurtenances shall be cleaned at intervals as required by Comments:Filters above fryers need cleaned to avoid the Sections 606.3.3.1 through 606.3.3.3. accumulation of grease. Portable Fire Extingusihers Code Descnpdon Fail 906.6-Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or Location:Kitchen-below ordering counter obscured from view.In rooms or areas in which visual obstruction cannot be completely avoided,means shall be Comments:Remove shelf obstructing clear access to fire extinguisher or relocate extinguisher to an approved readily provided to indicate the locations of extinguishers. accessible location. r a GENERATED ON 9/18/26, 9:42 AM 10 OF 11 r'® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/19/28, 9:42 AM 11 OF 11