Loading...
HomeMy WebLinkAboutSUNNY SPA MASSAGE-2022 FALLS AVE WA . INVOICE DATE DUE DATE INVOICE# TOTAL DUE O 0,6 0 10/02/2026 11/06/2026 2027-00000165 $50.00 • ''n O ■uIr u'u • *=T 0 Customer#: 25093 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SUNNY SPA MASSAGE 715 Mulberry St 2022 FALLS AVENUE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION -2022 FALLS AVE-09/28/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 1 $40.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES • 25093 10/02/2026 11/06/2026 2027-00000165 $50.00 Less Prepayment $0.00 Total Due -* $50.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Is Inspection Report 425 E.3rd Street 440 Sunny Spa Massage-2022 Fails AVE,BLDG 2022 Falls Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0912812026 Annual Inspection(1Yr) 0 C Et ,4 24439 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION 0 30 0 8 ® 39 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 11/03/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-09128/2026 @ 13:55 Space heaters shall be commercially listed,residentially listed heaters are prohibited. BRAD BALDWIN-0912812026 @ 13:55 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and S200 for all subsequent re-inspections. BRAD BALDWIN-0912812026 @ 13:55 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-09/28/2026 @ 13:55 •$50 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Dajuan Cao-2026 Date: _ BRAD BALDWIN 09/28/2026 CHECKLISTS GENERATED ON 0/28/2e, 2:36 PM 1 OF 7 Additional Codes Status Code Description Fall 1010.2.4-Locks and latches, O Locks and latches shall be permitted to prevent operation of Location:Front exit door doors where any of the following exist:1.Places of detention Comments:Update door hardware to comply with single motion or restraint.2.In Group I.1,Condition 2 and Group 1.2 requirement.Door hardware shall require no more than(1)single occupancies where the clinical needs of persons receiving motion to unlock and unlatch door,currently deadbolt and door knob care require containment or where persons receiving care requires 2 motions. pose a security threat,provided that all clinical staff can readily unlock doors at all times,and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups B,F,M and S, and In places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3.3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.8.0ther than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key- operated locking device.8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the Interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.e.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9.Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space. GENERATED ON a/28/26, 2:36 PR 2 OF 7 a Fall 603.1 - General. OElectrical equipment, wiring and systems required by this Location: Front room code or the International Building Code shall be installed, Comments: Remove microwave plugged to multi-plug adapter. used and maintained in accordance with NFPA 70 and Appliances including heating elements shall plug directly to a wall Sections 603.2 through 603.10. outlet. Fall 807.3 -Acceptance criteria and reports. OWhere required to exhibit improved fire performance, Location: Entire space curtains, draperies, fabric hangings and other similar Comments: Provide documentation of all curtains and draperies in combustible decorative materials suspended from walls or building meet proper flame spread index. Curtain & draperies not in ceilings shall be tested by an approved agency and meet the compliance shall be permanently removed. flame propagation performance criteria of Test Method 1 or Test Method 2, as appropriate, of NFPA 701 or exhibit a maximum rate of heat release of 100 kW when tested in accordance with NFPA 289, using the 20 kW ignition source. 0: -,. 4 iii:& . . , Reports of test results shall be prepared in accordance with the test method used and furnished to the fire code official upon request. ""� .. ....Ana.M.._e.. '` zed i a �t _ .. ..... _ . , Y ' .1:4"t# tihts*,0 1-1' ‘) lit . , { ' ' .;gip ..! E: y'. oaX�y�. --.� IT y �� ei r „� ...Tics.- lvdelfrapviv , . • . 1 '.. I. IhI GENERATED ON 9/28/26, 2:36 PM 3 OF 7 Electrical Safety S:a:us Code Description Fail 603.4•Working space and clearancesclearance. A working space of not Working space around electrical Location:Mechanical room equipment shall be provided in accordance with Section Comments:Remove all storage within 36 inches of electrical panel 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or and maintain clear path of access at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 Inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm), • ' 7. t MF • Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Mechanical room with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide permanent signage on closet doors indicating ROOM"or similar approved wording.The disconnecting "MECHANICAL ROOM"or other approved wording.Laminated paper means for each service,feeder or branch circuit originating will not be accepted as permanent. on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. GENERATED ON 0/28/26, 2:36 PM 4 OF 7 Fall 603.6•Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Front room below window for permanent wiring and shall be listed and labeled In Comments:Remove all extension cords.Also,please note: accordance with UL817.Extension cords and flexible Christmas lighting is approved for temporary use only(maximum 90 affixed not be affixed to structures,extended through days) walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical Impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. tiy.f a .t . i 4 j 4 .1 \\,..........) Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Near back door for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to candle warmer. accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 9/28/28, 2:38 PM 5 OF 7 Portable Fire Extingusihers Status Code Description Fall 906.2-General requirements. C Portable fire extinguishers shall be selected,installed and Location:Extinguisher maintained in accordance with this section and NFPA 10. Comments:Provide required annual service to extinguisher,no Exceptions:1.The distance of travel to reach an extinguisher current date of last service.If self-purchasing,a minimum of a 2-A:10- shall not apply to the spectator seating portions of Group A-5 B:C extinguisher with receipt shall be installed on a wall bracket 4"to occupancies.2.Thirty-day inspections shall not be required 5'off the floor,tape receipt to bottom of extinguisher and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 9/26/26, 2:38 PH 6 OF 7 '® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $50.00 Invoice Number Check Number Transaction Number N/A NIA NIA GENERATED ON 9/28/26, 2:38 PM 7 OF 7