Loading...
HomeMy WebLinkAboutscan-15 SULLIVAN BROTHERS CONVENTION CENTER WATERLOO, IOWA SKYWALK IMPROVEMENTS -- 5 SULLIVAN BROTHERS N CONVENTION CENTER. PROJECT GENERAL NOTES 1. ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS, WHICH INCLUDE, BUT ARE NOT LIMITED TO, THE OWNER - CONTRACTOR AGREEMENT, THE PROJECT MANUAL (WHICH INCLUDES GENERAL AND SUPPLEMENTARY CONDITIONS AND SPECIFICATIONS), DRAWINGS OF ALL DISCIPLINES AND ALL ADDENDA, MODIFICATIONS AND CLARIFICATIONS ISSUED BY THE ARCHITECT / ENGINEER. 2. CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL SUBCONTRACTORS BY THE GENERAL CONTRACTOR IN COMPLETE SETS IN ORDER TO ACHIEVE THE FULL EXTENT AND COMPLETE COORDINATION OF ALL WORK. CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND CORRELATING QUANTITIES AND DIMENSIONS. 3. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 4. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. NOTIFY ARCHITECT / ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 5. DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE OF DETAILING REQUIRED THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO DETAILS SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, NOTIFY ARCHITECT / ENGINEER BEFORE PROCEEDING WITH THE WORK. 6. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, CLEANED AND CONDITIONED ACCORDING TO MANUFACTURERS' INSTRUCTIONS. IN CASE OF DISCREPANCIES BETWEEN MANUFACTURERS' INSTRUCTIONS AND THE CONTRACT DOCUMENTS, NOTIFY ARCHITECT / ENGINEER BEFORE PROCEEDING WITH THE WORK. 7. LARGE-SCALE, MORE SPECIFIC DETAILS TAKE PRECEDENCE OVER SMALLER -SCALE, LESS SPECIFIC DETAILS AND INFORMATION. MORE STRINGENT REQUIREMENTS FOR CODE, PRODUCTS AND INSTALLATION TAKE PRECEDENCE OVER LESS STRINGENT REQUIREMENTS. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 8. PROVIDE CONTINUOUS SEALANT AROUND ALL MATERIALS AT EXTERIOR WALL PENETRATIONS. REFER TO SPECIFICATIONS FOR APPROPRIATE SEALANT. 9. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER TO AVOID GALVANIC CORROSION. ISG PROJECT # 19=23770 PROJECT GENERAL NOTES 10. SEAL ALL OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS, AROUND DUCTS, PIPES, VENTS, TRAPS, CONDUIT AND ALL OTHER PENETRATIONS WITH FIRE STOPPING AS SPECIFIED AND REQUIRED BY CODES. 11. PROVIDE TEMPORARY WALLS, ENCLOSURES, DUST SHIELDS AND WALK -OFF MATS AS REQUIRED TO SEPARATE DEMOLITION AND CONSTRUCTION FROM EXISTING BUILDING. 12. PROVIDE BRACING AND SHORING AS REQUIRED TO PROTECT EXISTING STRUCTURE TO REMAIN. PROVIDE SECURE AND WEATHERPROOF ENCLOSURE OF TEMPORARY OPENINGS IN EXTERIOR WALLS. PROTECT ALL BUILDING COMPONENTS FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION. 13. RESTORE ALL EXISTING AREAS AFFECTED BY DEMOLITION AND RELATED NEW CONSTRUCTION TO THEIR ORIGINAL CONDITION, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS, AND CEILINGS AND THEIR ASSOCIATED FINISHES. SHEET INDEX SHEET #, SHEET TITLE GENERAL 6G1-10 TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTES ARCHITECTURAL 6A1-21 SKYWALK ROOF AND FLOOR PLANS 6A2-11 SKYWALK ELEVATIONS, DETAILS, & DOOR SCHEDULE SEAL ESS /ON z coz . CODY •: z= = uJ VANASSE ' rm = �•: ARC07836 /��"��• /O W A `�����`��\\ rrlr111111 � SEAL �\\``��\ GESS I O v ,////, IASON � -IOEHN ; m '16140 I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE I AM A DULY LICENSED ENGINE R UNDER THE LAWS OF THE STATE OF IOWA. 04/07/2020 SI NATURE DATE CODY J. VANASSE PRINTED SIGNATURE ARC07836 06/30/2021 LICENSE NUMBER _ICENSE RENEWAL DATE SHEETS COVERED BY THIS SEAL: 6G1-10, 6A1-21, 6A2-11 I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE CHARGE I AM A DULY LICENSED EN INFER UNDER THE LAWS OF THE STATE OF IOWA. 04/07/2020 IGNATURE DATE JASON E HOEHN PRINTED SIGNATURE P16140 _ 12/31/2021 LICENSE NUMBER LICENSE RENEWAL DATE SHEETS COVERED BY THIS SEAL: 6A2-11 ABBREVIATIONS MATERIALS KEY TAGS AND SYMBOLS - ROOM NAME BATT INSULATION SECTION NUMBER RO MO # POUND OR NUMBER EX EXISTING MH MANHOLE SUSP SUSPENDED - � 1 @ A.C.T. AT ACOUSTICAL CEILING TILE EXP EXT EXPANSION EXTERIOR MIN MISC MINIMUM MISCELLANEOUS SV SY SHEET VINYL SQUARE YARDS - i ACONSTRUCTION NEW _ A C''CEILING j ADA AMERICANS WITH DISABILITIES ACT F&I FURNISH AND INSTALL MO MASONRY OPENING T&G TONGUE AND GROOVE / �� BRICK SECTION 1� GRIDS W WALL ADD ADDENDUM FA FRESH AIR MTD MOUNTED T&P TEMPERATURE AND PRESSURE Al-l1/* B,, BASE ADDL ADDITIONAL FAAP FIRE ALARM ANNUNCIATOR PANEL MULL MULLION TBD TO BE DETERMINED SHEET NUMBER F FLOOR ADJ AFF ADJACENT ABOVE FINISH FLOOR FACP FD FIRE ALARM CONTROL PANEL FLOOR DRAIN NA NIC NOT APPLICABLE NOT IN CONTRACT TEL TEMP TELEPHONE TEMPERATURE CONCRETE (SECTION) AHU AIR HANDLING UNIT FE FIRE EXTINGUISHER NTS NOT TO SCALE TER TERRAZZO Y ROOM / FINISHES LISTED IN ROOM ALT ALTERNATE FEC FIRE EXTINGUISHER CABINET OC ON CENTER TO TOP OF - -, ELEVATION NUMBER FINISH TAG TAG APPLY TO ALL ALUM ALUMINUM FF FLOOR FINISH OCEW ON CENTER EACH WAY TOF TOP OF FOUNDATION "" CMU SECTION (SECTION) INTERIOR I " �` ELEMENTS IN ROOM, APPROX APPROXIMATELY FFE FINISHED FLOOR ELEVATION OD OUTSIDE DIAMETER TOL TOP OF LEDGE � � EXTERIOR - SHEETNUMBER J M B E R 1 NOTED OTHERWISE ARCH ARCHITECTURAL FRP FIBERGLASS REINFORCED PLASTIC OH OVERHEAD TOS TOP OF STEEL Al-11-AUNLESS 2 B.O. BOTTOM OF OR BY OWNER FRZ FREEZER OL OVERALL LENGTH TOW TOP OF WALL ELEVATION BD BOARD FT FOOT OR FEET OPNG OPENING TP TOILET PARTITION - EARTH THE FOLLOWING SYMBOL BLDG BUILDING FTG FOOTING ORD OVERFLOW ROOF DRAIN TR TAMPER RESISTANT -- _- APPLIES TO FINISHES BRG BSMT BEARING BASEMENT GA GAUGE OSB ORIENTED STRAND BOARD TRANF TRANSFORMER EXISTING DIFFERENT FROM THOSE GALV GALVANIZED PC PHOTO CELL TS TUBE STEEL / THRESHOLD / TRANSITION STRIP ' . / CG CORNER GUARD GC GENERAL CONTRACTOR PLAM PLASTIC LAMINATE TV TELEVISION / GRANULAR FILL CONSTRUCTION B NOTED IN ROOM TAG: CIP CAST IN PLACE GFCI GROUND FAULT CIRCUIT INTERRUPT PLWP PLASTIC LAMINATE WALL PANEL TYP TYPICAL = / - 2� -_= ELEVATION NUMBERS GRIDS CJ CL CONTROL JOINT OR CONSTRUCTION JOINT CENTERLINE GL GLAZING PNT PAINT UH UNIT HEATER -- FINISH - -- GYP GYPSUM POLYETH POLYETHYLENE UNO UNLESS NOTED OTHERWISE INTERIOR ` CLG CEILING HD HUB DRAIN POLYISO POLYISOCYANURATE VCT VINYL COMPOSITE TILE GRAVEL ELEVATION 1 Al-11 3 CLR CLEAR HDG HOT DIP GALVANIZED PRV POWER ROOF VENTILATOR VERT VERTICAL CM CORRUGATED METAL HDW HARDWARE PVC POLYVINYL CHLORIDE VEST VESTIBULE // (ALTERNATIVE) CMU CONCRETE MASONRY UNIT HM HOLLOW METAL QT QUARRY TILE VIF VERIFY IN FIELD _ GYPSUM BOARD 4 SHEET NUMBER CO CLEANOUT HORIZ HORIZONTAL QTZ QUARTZ VTR VENT THROUGH ROOF OR SHEATHING CONC CONCRETE HSS HOLLOW STRUCTURAL SECTION RA RETURN AIR VWP VENEER WALL PANEL - _ CONF CONFERENCE HT HEIGHT RB RESILIENT BASE W/ WITH ONLY 0 N E DOOR CONT CONTINUOUS HVAC HEATING VENTILATION AND AIR CONDITIONING RBR RUBBER W/O WITHOUT _ RIGID INSULATION DETAIL NUMBER DOOR NUMBERS I IN A ROOM - C D S CATALOG NUMBER CPT CARPET ID INSIDE DIAMETER RCP REFLECTED CEILING PLAN WC WATER CLOSET ~� NUMBER 1 1C1 � FROM NORTH CR CHAIR RAIL IG ISOLATED GROUND RD ROOF DRAIN WCG WALL COVERING `SHEET - 1O1A AMERICAN CRK CT CORK CERAMIC IMP INFO INSULATED METAL PANEL INFORMATION REF RE REFRIGERATOR REINFORCED WD WF WOOD WALL FINISH PLYWOOD %` ►A1 11 MULTIPLE DOORS ARCHITECTURAL CY CUBIC YARDD INP IN -PLACE READQD REQUIRED WG WALL GUARD WOODWORK DEMO DEMOLITION INSUL INSULATION REV REVISION/REVISED WH WALL HYDRANT DETAIL CALLOUT N A ROOM STANDARDS (NAAWS) DF DRINKING FOUNTAIN INT INTERIOR RM ROOM WHTR WATER HEATER ' I CASEWORK DH DOOR HOLDER (MAGNETIC) JAN JANITOR RO ROUGH OPENING WP WEATHERPROOF(ELEC) SAND AREA OF DETAIL TAG �F "M" IS INCLUDED SEE DIA EA DIAMETER EACH JBE JST JOIST BEARING ELEVATION JOIST ROW/RW RTE RIGHT OF WAY REFER TO ELEVATION WWF WELDED WIRE FABRIC - - - WALL TYPE - - % NOTE BELOW F O R EF EXHAUSTFAN LAV LAVATORY RTU ROOF TOP UNIT - OF EIFS EXTERIOR INSULATION FINISH SYSTEM LB POUND SA SUPPLYAIRSTEELMODIFICATION)ELEC ZZ,DESCRIPTION ELECTRICAL LLH LONG LEG HORIZONTAL SC SEALED CONCRETE WINDOW TYPE AL15 J ELEV ELEVATION LLV LONG LEG VERTICAL SF SQUAREFOOT �(DSj NOMINAL EMERG ENCL EMERGENCY LN LINEAR SIM SIMILAR VIEW_ NAME W# .- DEPTH ENCLOSURE LVT LUXURY VINYL TILE SM SURFACE MOUNTED SYNTHETIC STUCCO DRAWING EQUIPMENT TYPE A _D#� _-- NOMINAL WIDTH EPDM ETHYLENE PROPYLENE DIENE MONOMER MATL MATERIAL SPEC SPECIFICATION TITLE 1 /8" = 1'-0" EPX EPDXY MAX MAXIMUM SS SOLID SURFACE _ MOD LINE 1 NO � MINAL HEIGHT EQ EQUAL MECH MECHANICAL SSTL STAINLESS STEEL FLOOR MOD LINE 2 EQUIP EQUIPMENT MEP MECHANICAL, ELECTRICAL, PLUMBING STD STANDARD WOOD MATERIAL TYPE F FIN-# -- DESCRIPTION OF ETC ETCETERA MEZZ MEZZANINE STN STONE - MODIFICATION FROM EWC ELECTRIC WATER COOLER MFR MANUFACTURER STOR STORAGE LEVEL 1 SPRAY IN PLACE ELEVATION --- -- --- MATERIAL TYPE FIN-# CDS CATALOG INSULATION 100'-01, PROJECT INDEX: OWNER: CITY OF WATERLOO GREG AHLHELM 715 MULBERRY STREET WATERLOO, IOWA 50703 4/7/2020 3:50:29 PM PROJECT ADDRESS: FIVE SULLIVAN BROTHERS CONVENTION CENTER 200 W 4TH STREET WATERLOO, IOWA 50701 MANAGING OFFICE: WATERLOO OFFICE 314 EAST 4TH STREET WATERLOO, IOWA 50703 PHONE: 319.234.1515 PROJECT MANAGER: NATHAN COMPTON EMAIL: NATHAN.COMPTON@ISGINC.COM THIS DOCUMENT IS THE PROPERTY OF I & S GROUP, INC. AND MAY NOT BE USED, COPIED OR DUPLICATED WITHOUT PRIOR WRITTEN CONSENT. PROJECT 5 SULLIVAN BROTHERS CONVENTION CENTER SKYWALK IMPROVEMENTS WATERLOO IOWA REVISION SCHEDULE DATE DESCRIPTION F—BY PROJECT NO. 19-23770 FILE NAME 5 SULLIVAN BROS PROJECTS ARCH R20 DRAWN BY LPU DESIGNED BY CJV REVIEWED BY CJV ORIGINAL ISSUE DATE 04/07/2020 CLIENT PROJECT NO TITLE TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTE l