HomeMy WebLinkAboutscan-3(:D COMMERCIAL STREET SKYWALK ELEVATION 8" = 1'-0" -- 4 COMMERCIAL STREET SKYWALK ELEVATION I (: ) 11 = 1'-011 PREFINISHED METAL FLASHING CONT. METAL RETAINER CLIP CONT. SEALANT - I EXISTING METAL - WALL PANELS TO REMAIN TYPICAL R00-F-EDGE DETAIL 1 1 /2" = 1'-0" 4/7/2020 3:50:26 PM - CONT. FLASHING TAPE WOOD BLOCKING FULLY ADHERED 90 MIL EPDM ROOF MEMBRANE, TURN DOWN AT ROOF EDGE 3.2" (MIN R-30) RIGID 'OLYISO. INSULATION SHEET METAL SCUPPER WOOD BLOCKING WRAP MEMBRANE FLASHING DOWN OVER FACE OF WOOD BLOCKING BEST WESTERN SECOND FLOOR SECOND 114' - 0'` INSTALL FASTENERS INTO SEALANT - HIGH DOMED, CAPPED, AND GASKETED FASTENERS @ 18" OC, FASTENING NEOPRENE PAD i REQUIREMENTS TO BE VERIFIED WITH ROOFING MANUFACTURER SCUPPER; STAGGER FASTENERS SHEET METAL COVER WITH -- SHEET METAL COUNTERFLASHING @ 3' OC INTO BLOCKING RECEIVER FOR COUNTERFLASHING MEMBRANE FLASHING SHEET A FASTENERS @ 8" OC / ,-- ROOF MEMBRANE, REFER TO WOOD CURB TYP ROOF EDGE DETAIL z w ROOF INSULATION, REFERO - - WOOD CANT FASTENED TO TO TYP ROOF EDGE DETAIL Z ? WOOD NAILERS o _ *- ¢ -- WOOD NAILERS FASTENED TO EXIST, ROOF DECK -- y'-- ROOF MEMBRANE, REFER TO TYP ROOF EDGE DETAIL EXISTING METAL ROOF DECK TO REMAIN, TO INSULATION, REFER REPAIR AND REPLACE AS NEEDED TO I TO TYP ROOF EDGE DETAIL MATCH EXISTING STRUCTURE EXISTING METAL ROOF DECK TO REMAIN, XISTING METAL ROOF DECK „: REPAIR AND REPLACE AS NEEDED TO 0 REMAIN, REPAIR AND - MATCH EXISTING STRUCTURE FPI me A nlccncn "rn fG MATCH EXISTING STRUCTURE 8 SCUPPER ROOF DRAIN DETAIL 1 /2" = 1'-0" ROOF TOP EQUIPMENT CURB DETAIL 1 /2" = 1'-0" LINTEL SCHEDULE MARK SIZE BEARING - -- - - -- - COMMENTS _- L1 W12x40 12" EACH END JALL TEMPORARY SHORING IS BY THE GENERAL CONTRACTOR. REFER TO ARCHITECTURAL DOCUMENTS FOR OPENING WIDTH AND ELEVATION -- -- 'NOTE: - DEMOLITION CONTRACTOR TO NOTIFY STRUCTURAL ENGINEER AFTER SHORING HAS BEEN INSTALLED AND PRIOR TO INSTALLATION OF NEW LINTELS TO CONFIRM EXISTING WALL AND LINTEL CONSTRUCTION INFILL W/ HALF BRICK SEALANT 7YP BOTH SIDES PL3/8"X12'XBEAM LENGTH 5 TYPICAL LINTEL DETAIL 2 -1 0 -- NEW PREFIN. METAL FLASHING TO TIE INTO -- « EXISTING PARAPET FLASHING FASTENERS @ 24" OC FASTENERS AT 8" OC OR PER -- _ - — NEW PREFIN. METAL DRIP FLASHING MANUFACTURER'S K = INSTRUCTIONS AIR INFILTRATION BARRIER , NEW 3/4" EXT. GRADE CDX PLYWOOD SHEATHING z — ROOF MEMBRANE, REFER TO CONT. CANT STRIP FASTENED -- _ TYP ROOF EDGE DETAIL TO WOOD NAILERS ry ' -- ROOF INSULATION REF TUCKPOINT SOLID, TYP BOTH SIDES LINTEL "L1" EXISTING BRICK TO REMAIN THIS DOCUMENT IS THE PROPERTY OF I & S GROUP, INC. AND MAY NOT BE USED, COPIED OR DUPLICATED WITHOUT PRIOR WRITTEN CONSENT. PROJECT 5 SULLIVAN BROTHERS CONVENTION CENTER SKYWALK WOOD NAILERS FASTENED - � ` � ER TO TYP ROOF EDGE DETAIL IMPROVEMENTS TO EXIST. ROOF DECK — NEW VAPOR BARRIER, TURN EXISTING METAL ROOF DECK - - - TO REMAIN, REPAIR AND _ REPLACE AS NEEDED TO __ 4t UP AND TIE INTO VERTICAL -;' INFILTRATION BARRIER $f WATERLOO IOWA MATCH EXISTING STRUCTURE - REVISION SCHEDULE a DATE -- DESCRIPTION - - - - BY - ROOF EDGE AT METAL -- - -- - - - - - - -SIDING- 1 1 /2" = 1-0" - - -- - — EXISTING MASONRY WALL --- --- CONTINUOUS THROUGH PROJECT NO. 19-23770 WALL FLASHING " SHEET METAL REGLET W/SEALANT --- FASTENERS @ 24" OC FILE NAME 5 SULLIVAN BROS PROJECTS ARCH R20 DRAWN BY LPU -- FASTENERS AT 8" OC OR PER - MANUFACTURER'S INSTRUCTIONS _--- NEW PREFIN. METAL DRIP FLASHING DESIGNED BY CJVREVIEWED BY CJV ORIGINAL ISSUE DATE 04/07/2020 CLIENT PROJECT NO. CONT. CANT STRIP FASTENED - - TO WOOD NAILERS -ROOF MEMBRANE, REFER TO TITLE WOOD NAILERS FASTENED TO EXIST. ROOF DECK EXISTING METAL ROOF DECK TO REMAIN, REPAIR AND REPLACE AS NEEDED TO MATCH EXISTING STRUCTURE ROOF EDGE AT MASONRY WALL 10 - - - -- -- ----- - -- - 1 1 /2" = 1'-0" TYP ROOF EDGE DETAIL S KYWA L K ROOF INSULATION, REFER TO TYP ROOF EDGE DETAIL ELEVATIONS, DETAILS, & DOOR SCHEDULE SHEET 6A2=1 I