RENTAL PROP INSPECTION- 1202 W 2ND ST#3-09/29/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
FAILURE TO OBTAIN PERMIT $100.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24033 10/05/2026 11/09/2026 2027-00000066 $100.00
Less Prepayment $0.00
Total Due -* $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloowl Fire Rescue
Inspection Report 425 E.3rd Street
Unit 3 upstairs Left-1202 W 2nd ST,BLDG 264 Baltimore,Waterloo IA 50701
INSPECTION DETAILS
Inspection Date Inspection Type p ��� � �� Inspection Number
09129/2026 2015 IPMC Rental Inspection 2 r°�
Lead Inspector Shift Station Unit
NATE BEUSELING NIA N/A N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
46 Q 13 Q 1
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
NATE BEUSELING 10/30/2026
nate.beuseling@waterloo-ia.org
GENERAL NOTES
NATE BEUSELING-09/3012026 @ 12:38
100 dollar fee for unit being unregistered at time of inspection
NATE BEUSELING-09/30/2026 @ 12:38
Outlet reads as open ground,repair or replace with 2 pronged outlet,GFCI outlet,GFCI Breaker in Panel
NATE BEUSELING-09/3012026 @ 12:38
All structural repairs,water heater replacement,furnace replacement and major electrical repairs require appropriate permits and inspections.
NATE BEUSELING-09/3012026 @ 12:37
Property Safety Inspector-nate.beuseling@waterloo-ia.org-Work:319-291-4319(#8)-Cell:319-464-5605
NATE BEUSELING-09130/2026 @ 12:37
Re-inspection date is as posted on the inspection report.The rental unit's responsible personls shall contact prior to inspection date to set up time of re-
inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to
occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep
the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150,
and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Israel Sanchez Date: NATE BEUSELING 0913012026
GENERATED ON 9/30/26, 12:39 PM 1 OF 4
CHECKLISTS
2015 IPMC Exterior Property
_,u_.0 Code Description
Fail 2015 IPMC 304.13•Window,skylight and door frames
;. Every window,skylight,door and frame shall be kept In Location:Living room
sound condition,good repair and weather tight. Comments:one window does not function
Fail 2015 IPMC 304.13-Window,skylight and door frames
Every window,skylight,door and frame shall be kept in Location:Living room
sound condition,good repair and weather tight. Comments:2nd window has broken window frame
Fail 2015 IPMC 304.13.2-Openable windows
Every window,other than a fixed window,shall be easily Location:Bedroom
openable and capable of being held in position by window Comments:Windows open but do not stay open shall be repaired to
hardware full function
2015 IPMC Egress Components
_,so oc:r_ Descnpnnn
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Unit
provided,and hardware shall be maintained in good Comments:Door and door frame in disrepair shall be repaired and
condition.Locks at all entrances to dwelling units and secured
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3.
2015 IPMC Interior Property
Status Code Description
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Unit 3
maintained in good,clean and sanitary condition.Peeling, Comments:All Drywall holes in walls and ceiling shall be repaired in
chipping,flaking or abraded paint shall he repaired,removed all units using licensed contractors with permits and inspections
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC Water System
Status Code Description
Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture
C Location:Bathroom
Requirements
Plumbing fixtures shall be properly installed and maintained Comments:Sink slow to drain,investigate cause and repair
in working order,and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture
Requirements
Location:Bathroom
Plumbing fixtures shall be properly installed and maintained Comments:Toilet slow to fill,investigate cause and repair
in working order,and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
GENERATED ON 9/30/26, 12:39 PM 2 or a
2015 IPMC Electrical
Status Code Description
Fall 2015 IPMC 605.2 • Receptacles
Every habitable space in a dwelling shall contain not less Location: Kitchen
than two separate and remote receptacle outlets. Every Comments: Outlets read open ground shall be replaced with GFCI
laundry area shall contain not less than one grounding-type outlets
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Fail 2015 IPMC 605.2 - Receptacles
Ox Every habitable space in a dwelling shall contain not less Location: Bedroom
than two separate and remote receptacle outlets. Every Comments: Outlets in bedroom read as hot neutral reverse shall be
laundry area shall contain not less than one grounding-type repaired
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Fail 2015 IPMC 605.3 - Luminaires
Every public hall, interior stairway, toilet room, kitchen, Location: Unit
bathroom, laundry room, boiler room and furnace room shall Comments: All light fixtures need to have appropriate globes
contain not less than one electric lurninaire. Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 603.5 - Relocatable power taps and current taps.Multiplug
0 adapters. Location: bedroom
Multiplug adapters, such as cube adapters, unfused plug Comments: AC unit plugged into power strip must be plugged into
strips or any other device not complying with NFPA 70 shall wall
be prohibited. The construction and use of current taps and
relocatable taps shall be in accordance with NFPA 70 and this
code.
2015 IPMC Fire Protection
status Code Description
Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and I-1
0 Single or multiple-station smoke alarms shall be installed and Location: Unit
maintained in Groups R-2, R-3, R-4 and I-1 regardless of
Comments: Smoke detectors are required in sleeping rooms and in
occupant load at all of the following locations: 1. On the hallway outside sleeping room install accordingly
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2021 IRC R315.3 - Carbon Monoxide Detection: Location
Carbon monoxide alarms in dwelling units shall be installed Location: Unit
outside of each separate sleeping area in the immediate Comments: CO detection must be placed outside of sleeping rooms
vicinity of the bedrooms. Where a fuel-burning appliance is
located within bedroom or its attached bathroom, a carbon
monoxide alarm shall be installed within the bedroom.
GENERATED ON 9/30/26, 12:39 PM 3 OF 4