Loading...
HomeMy WebLinkAboutIA INVESTMENT PROPERTY - 1202 W 2ND ST #3 �f W A rF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 10/05/2026 11/09/2026 2027-00000066 $100.00 u` rit o • •II II II III II II • > T O Customer#: 24033 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable IA INVESTMENT PROPERTY 715 Mulberry St 5195 HAMPSTEAD VILLAGE CTR WAY WATERLOO, IA 50703 NEW ALBANY, OH 43054 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL PROP INSPECTION- 1202 W 2ND ST#3-09/29/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price FAILURE TO OBTAIN PERMIT $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24033 10/05/2026 11/09/2026 2027-00000066 $100.00 Less Prepayment $0.00 Total Due -* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloowl Fire Rescue Inspection Report 425 E.3rd Street Unit 3 upstairs Left-1202 W 2nd ST,BLDG 264 Baltimore,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type p ��� � �� Inspection Number 09129/2026 2015 IPMC Rental Inspection 2 r°� Lead Inspector Shift Station Unit NATE BEUSELING NIA N/A N/A Other Inspectors N/A SUMMARY OF INSPECTION 46 Q 13 Q 1 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date NATE BEUSELING 10/30/2026 nate.beuseling@waterloo-ia.org GENERAL NOTES NATE BEUSELING-09/3012026 @ 12:38 100 dollar fee for unit being unregistered at time of inspection NATE BEUSELING-09/30/2026 @ 12:38 Outlet reads as open ground,repair or replace with 2 pronged outlet,GFCI outlet,GFCI Breaker in Panel NATE BEUSELING-09/3012026 @ 12:38 All structural repairs,water heater replacement,furnace replacement and major electrical repairs require appropriate permits and inspections. NATE BEUSELING-09/3012026 @ 12:37 Property Safety Inspector-nate.beuseling@waterloo-ia.org-Work:319-291-4319(#8)-Cell:319-464-5605 NATE BEUSELING-09130/2026 @ 12:37 Re-inspection date is as posted on the inspection report.The rental unit's responsible personls shall contact prior to inspection date to set up time of re- inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150, and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Israel Sanchez Date: NATE BEUSELING 0913012026 GENERATED ON 9/30/26, 12:39 PM 1 OF 4 CHECKLISTS 2015 IPMC Exterior Property _,u_.0 Code Description Fail 2015 IPMC 304.13•Window,skylight and door frames ;. Every window,skylight,door and frame shall be kept In Location:Living room sound condition,good repair and weather tight. Comments:one window does not function Fail 2015 IPMC 304.13-Window,skylight and door frames Every window,skylight,door and frame shall be kept in Location:Living room sound condition,good repair and weather tight. Comments:2nd window has broken window frame Fail 2015 IPMC 304.13.2-Openable windows Every window,other than a fixed window,shall be easily Location:Bedroom openable and capable of being held in position by window Comments:Windows open but do not stay open shall be repaired to hardware full function 2015 IPMC Egress Components _,so oc:r_ Descnpnnn Fail 2015 IPMC 304.15-Doors Exterior doors,door assemblies,operator systems if Location:Unit provided,and hardware shall be maintained in good Comments:Door and door frame in disrepair shall be repaired and condition.Locks at all entrances to dwelling units and secured sleeping units shall tightly secure the door.Locks on means of egress doors shall be in accordance with Section 702.3. 2015 IPMC Interior Property Status Code Description Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Unit 3 maintained in good,clean and sanitary condition.Peeling, Comments:All Drywall holes in walls and ceiling shall be repaired in chipping,flaking or abraded paint shall he repaired,removed all units using licensed contractors with permits and inspections or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. 2015 IPMC Water System Status Code Description Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture C Location:Bathroom Requirements Plumbing fixtures shall be properly installed and maintained Comments:Sink slow to drain,investigate cause and repair in working order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture Requirements Location:Bathroom Plumbing fixtures shall be properly installed and maintained Comments:Toilet slow to fill,investigate cause and repair in working order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition GENERATED ON 9/30/26, 12:39 PM 2 or a 2015 IPMC Electrical Status Code Description Fall 2015 IPMC 605.2 • Receptacles Every habitable space in a dwelling shall contain not less Location: Kitchen than two separate and remote receptacle outlets. Every Comments: Outlets read open ground shall be replaced with GFCI laundry area shall contain not less than one grounding-type outlets receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. Fail 2015 IPMC 605.2 - Receptacles Ox Every habitable space in a dwelling shall contain not less Location: Bedroom than two separate and remote receptacle outlets. Every Comments: Outlets in bedroom read as hot neutral reverse shall be laundry area shall contain not less than one grounding-type repaired receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. Fail 2015 IPMC 605.3 - Luminaires Every public hall, interior stairway, toilet room, kitchen, Location: Unit bathroom, laundry room, boiler room and furnace room shall Comments: All light fixtures need to have appropriate globes contain not less than one electric lurninaire. Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection. Fail 603.5 - Relocatable power taps and current taps.Multiplug 0 adapters. Location: bedroom Multiplug adapters, such as cube adapters, unfused plug Comments: AC unit plugged into power strip must be plugged into strips or any other device not complying with NFPA 70 shall wall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 2015 IPMC Fire Protection status Code Description Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and I-1 0 Single or multiple-station smoke alarms shall be installed and Location: Unit maintained in Groups R-2, R-3, R-4 and I-1 regardless of Comments: Smoke detectors are required in sleeping rooms and in occupant load at all of the following locations: 1. On the hallway outside sleeping room install accordingly ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2021 IRC R315.3 - Carbon Monoxide Detection: Location Carbon monoxide alarms in dwelling units shall be installed Location: Unit outside of each separate sleeping area in the immediate Comments: CO detection must be placed outside of sleeping rooms vicinity of the bedrooms. Where a fuel-burning appliance is located within bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom. GENERATED ON 9/30/26, 12:39 PM 3 OF 4 ffi Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/38/26, 12:39 PM 4 OF 4