Loading...
HomeMy WebLinkAboutIA INVESTMENT PROPERTY-1202 W 2ND ST #4 W A I. INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 . F 1 t 10/05/2026 11/09/2026 2027-00000067 $100.00 e I o ;,trivia" • n n iiu • > T T p 3 3S 7tl17‘5 Customer#: 24033 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable IA INVESTMENT PROPERTY 715 Mulberry St 5195 HAMPSTEAD VILLAGE CTR WAY WATERLOO, IA 50703 NEW ALBANY, OH 43054 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL PROP INSPECTION- 1202 W 2ND ST#4-09/29/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price FAILURE TO OBTAIN PERMIT $100.00 CUSTOMER# BILLING DATE _ DUE DATE INVOICE# CHARGES 24033 10/05/2026 11/09/2026 2027-00000067 $100.00 Less Prepayment $0.00 Total Due —> $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue 19 Inspection Report 425 E.3rd Street " Unit 4 Upstairs Right-1202 W 2nd ST,BLDG 264 Baltimore,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 09/29/2026 2015 IPMC Rental Inspection if Y4456 Lead Inspector Shift Station Unit NATE BEUSELING NIA N/A N/A Other inspectors NIA SUMMARY OF INSPECTION 0 48 0 10 ® 1 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date NATE BEUSELING 10/30/2026 nate.beuseling@waterloo-ia.org GENERAL NOTES NATE BEUSELING-09/30/2026 @ 13:37 Property Safety Inspector-nate.beuseling@waterloo-ia.org-Work:319-291-4319(#8)-Cell:319-464-5605 NATE BEUSELING-09130/2026 @ 13:36 Outlet reads as open ground,repair or replace with 2 pronged outlet,GFCI outlet,GFCI Breaker in Panel NATE BEUSELING-09/3012026 @ 13:36 Re-inspection date is as posted on the inspection report.The rental unit's responsible person/s shall contact prior to inspection date to set up time of re- inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to occupants of the unit/S.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150, and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections. SIGNATURES Contact signature Inspector signature >pNo signature Report completed post inspection Israel Sanchez Date: NATE BEUSELING 09130/2026 CHECKLISTS GENERATED ON G/30/26, 1:39 PM 1 OF 5 2015 IPMC Interior Property Status Code Description Fall 2015 IPMC 305.3•Interior surfaces Interior surfaces,including windows and doors,shall be Location:Unit maintained in good,clean and sanitary condition.Peeling, Comments:All drywall and flooring shall be in good condition repair chipping,flaking or abraded paint shall be repaired,removed if necessary or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. 2015 IPMC Water System Code Description Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture Requirements Location:Bathroom Plumbing fixtures shall be properly installed and maintained Comments:Accordion flexible piping observed,shall be replaced in working order,and shall be kept free from obstructions, with smooth standard plumbing fixture leaks and defects and be capable of performing the function for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition {/ tD k ` we- 2015 IPMC Mechanical Cod Description Fail 2015 IPMC 603.1-Mechanical appliances Mechanical appliances,fireplaces,solid fuel-burning Location:Living room and bedroom appliances,cooking appliances and water heating appliances Comments:Baseboard covers in disrepair shall be replaced shall be properly installed and maintained in a safe working condition,and shall be capable of performing the intended function. GENERATED ON G/30/2G, 1:30 Pk 2 OF S 2015 IPMC Electrical Code Description Fail 2015 IPMC 605.2-Receptacles Every habitable space in a dwelling shall contain not less Location:Living room than two separate and remote receptacle outlets.Every laundry area shall contain not less than one grounding-type Comments:Outlets need appropriate covers on them receptacle or a receptacle with a ground fault circuit interrupter.Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection.All receptacle outlets shall have the appropriate faceplate cover for the location. Fail 2015 IPMC 605.3-Luminaires Every public hall,interior stairway,toilet room,kitchen, Location:bathroom bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture by bathroom missing appropriate globe contain not less than one electric luminaire.Pool and spa luminaires over 15 V shall have ground fault circuit shall be replaced interrupter protection. Fail 2015 IPMC 605.3-Luminaires Every public hall,interior stairway,toilet room,kitchen, Location:Bedroom bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture missing appropriate globe shall replace contain not less than one electric luminaire.Pool and spa luminaires over 15 V shall have ground fault circuit globe interrupter protection. Fail 2015 IPMC 605.3-Luminaires Every public hall,interior stairway,toilet room,kitchen, Location:Kitchen bathroom,laundry room,boiler room and furnace room shall contain not less than one electric luminaire.Pool and spa Comments:globe on light fixture missing shall be replaced luminaires over 15 V shall have ground fault circuit interrupter protection. Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Bedroom Identified electrical hazards shall be abated.Identified Comments:Light switch missing cover in bedroom,replace cover hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. GENERATED ON 9/30/26, 1:39 PM 3 OF 5 2015 IPMC Fire Protection Status Cnrf=, Description Fall 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I.1 OSingle or multiple-station smoke alarms shall be installed and Location:living room maintained in Groups R-2,R-3,R-4 and I.1 regardless of Comments:smoke detector should be added in living room occupant load at all of the following locations:1.On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2021 IRC R315.3-Carbon Monoxide Detection:Location Carbon monoxide alarms in dwelling units shall be installed Location:Living room outside of each separate sleeping area in the immediate Comments:CO detection shall be added vicinity of the bedrooms.Where a fuel-burning appliance is located within bedroom or its attached bathroom,a carbon monoxide alarm shall be installed within the bedroom. 4 OF 5 GENERATED ON 9/38/28, 1:39 PH 'o Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/30/28, 1:39 PM 5 OF 5