RENTAL PROP INSPECTION- 501 FOWLER-09/23/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24932 10/05/2026 11/09/2026 2027-00000063 $150.00
Less Prepayment $0.00
Total Due —> $150.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report 425 E.3rd Street
501 Fowler Street-501 Fowler ST,Waterloo IA 50703-4041 qf_ t"TC�
UtAIGe
INSPECTION DETAILS
((;
Inspection Date Inspection TypeInspection Number
IV
09123/2026 2015 IPMC Rental Inspection REINSPECTION � . . 23613-Ri
Lead Inspector Shift Station Unit
Randy Girsch NIA N/A NIA
Other Inspectors
N/A
SUMMARY OF INSPECTION
� 0 x026
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
Randy Girsch 10126/2026
randy.girsch@waterloo-ia.org
GENERAL NOTES
Randy Girsch-09125/2026 @ 10:33
A reinspection for 501 Fowler was set for September 8th.Mr.Bentley called me and stated it was not finished and needed more time.We moved the
inspection to September 16th.On Tuesday September 15th I received at text from phone#319-238-3598 asking me I could push the inspection to
Wednesday September 23rd.I answered the text that I could do it on the 23rd at 1pm.I received a reply"That's fine".I arrived on the 23rd at 1pm and
waited at the residence until about 125pm.I then left the residence.Due to the fact no one showed up for the inspection there is a$100.00 fee.Due to the
house not passing inspections a S50.00 fee will also be issued.
Randy Girsch-08/03/2026 @ 15:59
Re-inspection date is as posted on the inspection report.The rental unit's responsible person/s shall contact prior to inspection date to set up time of re-
inspection.If all corrections are made before scheduled inspection,you ca n call to set up an earlier re-inspection.Please give the appropriate notices to
occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep
the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150,
and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completedeelpost inspection
nspection
QFI-B Holdings LLC Date: Randy Girsch 0912512026
CHECKLISTS
GENERATED ON 9/25/25, 10:35 AM 1 OF 12
Reinspection
S'tuis Code Description
Fail 2015 IPMC 302.5-Rodent harborage
Structures and exterior property shall be kept free from Location:Kitchen
rodent harborage and infestation.Where rodents are found, Comments:Tenant complain of mice,Found evidence and droppings
they shall be promptly exterminated by approved processes from mice.
that will not be injurious to human health.After pest
elimination,proper precautions shall be taken to eliminate
rodent harborage and prevent reinfestation.
77i
J
.`tA VI
•
•
Fail 2015 IPMC 304.13.2-Openable windows
Every window,other than a fixed window,shall be easily Location:Bedroom#1
openable and capable of being held in position by window
Comments:All windows in this room will not open.All windows need
hardware to be easily openable and stay open without assistance
Fail 2015 IPMC 304.13.2-Openable windows
Every window,other than a fixed window,shall be easily Location:Bedroom#2(clockwise)
openable and capable of being held in position by window Comments:West window will not open.All widows need open easily
hardware and need to stay open without assistance.
GENERATED ON 9/25/26, 20:35 AM 2 OF 1.2
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Living room
maintained in good,clean and sanitary condition.Peeling, Comments:Drywall and ceiling falling down.Needs to be repaired.
chipping,flaking or abraded paint shall be repaired,removed Possible moisture and possible mold.Needs to be eliminated.
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
�-,r •;.
.✓�-
d " "��
y� 2x r
ir
Fail 2015 IPMC 305.5-Handrails and guards
Every handrail and guard shall be firmly fastened and capable Location:Steps to the upstairs
of supporting normally imposed loads and shall be Comments:Missing hand rail.Make sure hand rails are in place,
maintained in good condition
secured,and up to code.
Fail 2015 IPMC 307.1-General-Handrails&Guards
Every exterior and interior flight of stairs having more than Location:Stairs to basement
four risers shall have a handrail on one side of the stair and Comments:Missing hand rail.Make sure handrail is installed and all
every open portion of a stair,landing,balcony,porch,deck, handrails are secure.
ramp or other walking surface that is more than 30 inches
(762 mm)above the floor or grade below shall have guards.
Handrails shall be not less than 30 inches(762 mm)in height
or more than 42 inches(1067 mm)in height measured
vertically above the nosing of the tread or above the finished
floor of the landing or walking surfaces.Guards shall be not
less than 30 inches(762 mm)in height above the floor of the
landing,balcony,porch,deck,or ramp or other walking
surface.
GENERATED ON 0/25/20, 10:35 AM 3 OF 12
Fail 2015 IPMC 307.1-General-Handrails&Guards
Every exterior and interior flight of stairs having more than Location:Back deck
four risers shall have a handrail on one side of the stair and Comments:Missing/damaged vertical rails on deck need to be
every open portion of a stair,landing,balcony,porch,deck, replaced and in good repair
ramp or other walking surface that is more than 30 inches
(762 mm)above the floor or grade below shall have guards.
Handrails shall be not less than 30 inches(762 mm)in height
or more than 42 inches(1067 mm)in height measured
vertically above the nosing of the tread or above the finished
floor of the landing or walking surfaces.Guards shall be not
less than 30 inches(762 mm)in height above the floor of the
landing,balcony,porch,deck,or ramp or other walking
surface.
/ i
-
it
9
;,' $ 1,.-,,,H-. zr-:7 --. ( 4::
iii
f}�ll T it.
GENERATED ON 9/25/26, 10:35 AM 4 OF 12
Fail 2015 IPMC 504.1•General-Plumbing Facilities and Fixture
Requirements Location:Basement
Plumbing fixtures shall be properly installed and maintained Comments:Water dripping from pipe that feeds ice maker in the
in working order,and shall be kept free from obstructions, refrigerator in kitchen.Needs to be corrected and free of leaks
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
•
Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture
Requirements Location:Basement
Plumbing fixtures shall be properly installed and maintained Comments:Water service is leaking.This is dripping onto wood and
in working order,and shall be kept free from obstructions, rotting it.Needs to be corrected.
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
GENERATED ON 0/25/20, 10:35 AM 5 OF 12
Fail 2015 IPMC 605.2•Receptacles
Every habitable space in a dwelling shall contain not less Location:Bathroom right of sink
than two separate and remote receptacle outlets.Every Comments:Broken outlet/receptacle.Needs to be replace and must
laundry area shall contain not less than one grounding-type be GFCI
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
�aek
�t
S
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less Location:Kitchen
than two separate and remote receptacle outlets.Every Comments:GFCI by sink not operating.Needs to function correctly
laundry area shall contain not less than one grounding-type and needs to be GFCI.
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
GENERATED ON 9/25/28, 10:35 AM 6 OF 12
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less Location:Bedroom#1(clockwise)
than two separate and remote receptacle outlets.Every Comments:Receptacle/outlet cover missing and need to be replaced.
laundry area shall contain not less than one grounding-type
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
1
I\\..\
v-,, !....: *isi,
f
•
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less Location:Bedroom#3(clockwise)
than two separate and remote receptacle outlets.Every Comments:Made sure all receptacles are operating correctly.
laundry area shall contain not less than one grounding-type
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
GENERATED ON 9/25/26, 10:35 AM 7 OF 12
Fail 2015 IPMC 605.3-Luminaires
Every public hall,interior stairway,toilet room,kitchen, Location:Front porch
Bathroom,laundry room,boiler room and furnace room shall Comments:Missing globe or part of light fixture.Repair or replace
contain not less than one electric luminaire.Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 605.3-Luminaires
OEvery public hall,interior stairway,toilet room,kitchen, Location:Basement
bathroom,laundry room,boiler room and furnace room shall Comments:Several light fixtures do not have bulbs in them or light
contain not less than one electric luminaire.Pool and spa bulbs are broken out.All need to be in working order.
luminaires over 15 V shall have ground fault circuit
interrupter protection.
l •
f
GENERATED ON 9/25/25, 10:35 AM 8 OF 12
Fail 2015 IPMC 605.3-Luminaires
Every public hall,interior stairway,toilet room,kitchen, Location:Side exit door light
bathroom,laundry room,boiler room and furnace room shall Comments:Missing globe.Needs to function and in good repair.
contain not less than one electric luminaire.Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
mlitNiiii‘„
.4\NN
ti
v
1,,.,.-.. --",-.::
Fail 2015 IPMC 605.3-Luminaires
Every public hall,interior stairway,toilet room,kitchen, Location:Dining room
bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture not working needs to be replaced or
contain not less than one electric luminaire.Pool and spa repaired.
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and 1.1
Single or multiple-station smoke alarms shall be installed and Location:Main Level
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Missing smoke detector.There must be a smoke detector
occupant load at all of the following locations:1.On the on each level.
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location:Basement
maintained in Groups R-2,R-3,R-4 and I•i regardless of Comments:Missing smoke detector.There must be a smoke detector
occupant load at all of the following locations:1.On the on each level.
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
GENERATED ON 0/25/2G, 10:35 AM 9 OF 12
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-i
Single or multiple-station smoke alarms shall be Installed and Location:Upstairs outside of bedrooms
maintained in Groups R-2,R-3,R-4 and I=1 regardless of Comments:Missing smoke detector.There must be a smoke detector
occupant load at all of the following locations:1.On the outside of each bedroom or cluster of bedrooms,
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and 1-1
Single or multiple-station smoke alarms shall be installed and Location:Bedroom#1(cicokwise)
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Missing smoke detector.There must be a working smoke
occupant load at all of the following locations:1.On the detector inside each bedroom.
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location:Bedroom#2(clockwise)
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Missing smoke detector.There must be a working smoke
occupant load at all of the following locations:1.On the detector inside each bedroom.
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location:Bedroom#3(clockwise)
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Missing smoke detector.There must be a working smoke
occupant load at all of the following locations:1.On the detector inside each bedroom.
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2021 IRC R 314.1.1-Smoke Alarms:Listings
Smoke alarms shall be listed in accordance with UL 217, Location:Entire dwelling
Combination smoke and carbon monoxide alarms shall be Comments:All smoke detector must be lOyear sealed UL217 listed
listed in accordance with 217 and UL 2034
GENERATED ON 0/?t/26, 10:35 AM
10 OF 12
Fail 2021 IRC R315,3-Carbon Monoxide Detection:Location
Carbon monoxide alarms in dwelling units shall be installed Location:In hallway outside bedrooms
outside of each separate sleeping area in the immediate Comments:Missing carbon monoxide detector.There must be a
vicinity of the bedrooms.Where a fuel-burning appliance is working carbon monoxide detector outside of bedrooms or cluster of
located within bedroom or its attached bathroom,a carbon bedroom.A carbon monoxide I smoke combo works well
monoxide alarm shall be installed within the bedroom.
Fail 603.2-Abatement of unsafe conditions and electrical
hazards. Location:Basement
Identified electrical hazards shall be abated.Identified Comments:Receptacle handing from wire and not secure to
hazardous electrical conditions in permanent wiring shall be anything.Needs to be secured properly.
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.