RENTAL PROP INSPECTION - 325 SUNNYSIDE AVE-09/15/26 FOR BILLING INQUIRY: (319)291-4323
Description. Total Price
FAILURE TO OBTAIN PERMIT $100.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
25094 10/05/2026 11/09/2026 2027-00000062 $100.00
Less Prepayment $0.00
Total Due $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
,r Waterloo Fire Rescue
',- Inspection Report AKele CSe 425 E.3rd Street
325 Sunnyside Avenue-325 Sunnyside AVE,Waterloo IA 50701-2543 6
3goi5 DaU �, '
INSPECTION DETAILS 261 ijv Y61 J �I �✓5�0
Inspection Date Inspection Type GS �" 1 Inspection Number
09/15/2028 2015 IPMC Rental Inspectionc;75 q 4 (C0,47D 24289
Lead Inspector Shift Station Unit
Randy Girsch NIA N/A N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
0 28 ® 43 @ 9
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
Randy Girsch
10/16/2026
randy.girsch@waterloo-ia.org
GENERAL NOTES
Randy Girsch-09116/2026 @ 09:11
On July 20th 2026 I called the owner of this residence.She told me that her friend was renting from her and gave me the tenants number to set up the
inspection.I told her that she needed to get the rental registered.I did not hear back from her and called back August 20th 2026 and reminded her that I
needed it inspected and registered.I later got a hold of the tenant and set up the inspection.It was set for September 15th 2026 and at the time of the
inspection the rental was still not registered.A have issued a fee of$100.00 for not having the house registered with the city.
Randy Girsch-09116/2026 @ 08:35
I will note that the tenant of this house has two grown up sons.On was in the basement and was sleeping.We were unable to inspect the basement where
he was sleeping.As far as I know the basement has not windows that meet egress and bedrooms would not be allowed.The other son was in an upstairs
bedroom and we did not inspect that room on this trip to the house either.
SIGNATURES
Contact signature Inspector signature
No signature
(\i\
Report completed post inspection
Anne E.Cole Date: Randy Girsch 09/16/2026
CHECKLISTS
GENERATED ON 9/22/26, 12:11 PM 1 OF 28
2015 IPMC Unsafe Structures and Equipment
Status Code Description
Fail 2015 IPMC 108.1.1-Unsafe structures
0 Unsafe structures.An unsafe structure is one that is found to Location:Living room tdiningroom
be dangerous to the life,health,property or safety of the Comments:Broke glass and shards of glass from building cabinets
public or the occupants of the structure by not providing not cleaned up could be a hazard to people and animals,
minimum safeguards to protect or warn occupants in the
event of fire,or because such structure contains unsafe
equipment or is so damaged,decayed,dilapidated,
structurally unsafe or of such faulty construction or unstable
foundation,that partial or complete collapse is possible.
Fail 2015 IPMC 108.1.1-Unsafe structures
LCJ Unsafe structures.An unsafe structure is one that is found to Location:Bedroom on main level by front door
be dangerous to the life,health,property or safety of the Comments:Plaster fell on tenant while sleeping.There is some left
public or the occupants of the structure by not providing p g'
that needs to come down.
minimum safeguards to protect or warn occupants in the
event of fire,or because such structure contains unsafe
equipment or is so damaged,decayed,dilapidated,
structurally unsafe or of such faulty construction or unstable
foundation,that partial or complete collapse is possible.
/tom r, f E„,, 4.,' i '`'
• - ';':-',..',..7* „ )'/./... / -/- '.,..-
e ham, ���
-‘{ ys v, ., 1 zYv Y/i t J i'
/ -, >�
L,p,,
/ Iva I'.
re
Pass 2015 IPMC 108.1.2-Unsafe equipment
C) Unsafe equipment includes any boiler,heating equipment,
elevator,moving stairway,electrical wiring or device,
flammable liquid containers or other equipment on the
premises or within the structure which is in such disrepair or
condition that such equipment is a hazard to life,health,
property or safety of the public or occupants of the premises
or structure.
Fail 2015 IPMC 108.1.3-Structure unfit for human occupancy
j A structure is unfit for human occupancy whenever the code Location:Entire dwelling
official finds that such structure is unsafe,unlawful or, Comments:This inspector finds this residence unfit for occupancy
because of the degree to which the structure is in disrepair or due to the fact that it is in such disrepair and the lack of maintenance
lacks maintenance,is insanitary,vermin or rat infested, inside and out and the fact that it is unsanitary,lacks basic egress,
contains filth and contamination,or lacks ventilation, security,and proper and up to code electrical needs I find it unfit to
illumination,sanitary or heating facilities or other essential occupy.
equipment required by this code,or because the location of
the structure constitutes a hazard to the occupants of the
structure or to the public.
GENERATED ON 9/22/28, 12:11 PM 2 OF 28
•
2015 IPMC Exterior Property
Status ucde Description
Pass 2015 IPMC 302.5-Rodent harborage
0 Structures and exterior property shall be kept free from
rodent harborage and infestation.Where rodents are found,
they shall be promptly exterminated by approved processes
that will not be injurious to human health.After pest
elimination,proper precautions shall be taken to eliminate
rodent harborage and prevent reinfestation.
Pass 2015 IPMC 304.11-Chimneys and towers
OChimneys,cooling towers,smoke stacks,and similar
appurtenances shall be maintained structurally safe and
sound,and in good repair.Exposed surfaces of metal or
wood shall be protected from the elements and against decay
or rust by periodic application of weather coating materials,
such as paint or similar surface treatment.
Fail 2015 IPMC 304.13-Window,skylight and door frames
OEvery windo ,skylight,door and frame shall be kept in Location:Living room
sound condition,w good repair and weather tight. Comments:Broke window.Must be replaced
1
410.
ill4
ill
i
iill - f'-'1.-I •----,---J-- ::
'- - ' . -'''--le- t--'---- ''' '
0 4 .'' le ,, ,,
`st .
GENERATED ON 0/22/26, 12:11 PM 3 OF 28
Fail 2015 IPMC 304.13-Window,skylight and door frames
Every window,skylight,door and frame shall be kept in Location:Window at the bottom of the steps outside of kitchen
sound condition,good repair and weather tight. Comments:Two broken windows.These are a hazard due to broken
glass.They will need to be repaired.Once window is repaired I will
need to check that it opens
f ;1
:
Fail 2015 IPMC 304.13-Window,skylight and door frames
Every window,skylight,door and frame shall be kept in Location:Window between living room and portch
sound condition,good repair and weather tight. Comments:Window is broken out and boarded up.This needs to be
replaced.
f
Pass 2015 IPMC 304.13.2-Openable windows
Every window,other than a fixed window,shall be easily
openable and capable of being held in position by window
hardware
GENEPATED ON 9/222/2,, 12;1:1 PH 4 OF 28
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:On front portch
provided,and hardware shall be maintained in good Comments:Door in not plum or weather tight,missing dead bolt and
condition.Locks at all entrances to dwelling units and does not lock.
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3.
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Rear door
provided,and hardware shall be maintained in good Comments:Door needs to operate correctly and be weather tight.I
condition.Locks at all entrances to dwelling units and was able to see day light from the inside of the house with the door
sleeping units shall tightly secure the door.Locks on means shut.
of egress doors shall be in accordance with Section 702.3.
ft► i •
•
O
N/A 2015 IPMC 304.16-Basement hatchways
Every basement hatchway shall be maintained to prevent the
entrance of rodents,rain and surface drainage water.
Pass 2015 IPMC 304.18-Building security
ODoors,windows or hatchways for dwelling units,room units
or housekeeping units shall be provided with devices
designed to provide security for the occupants and property
within.
Pass 2015 IPMC 304.18.2-Windows
Operable windows located in whole or in part within 6 feet
(1828 mm)above ground level or a walking surface below that
provide access to a dwelling unit,rooming unit or
housekeeping unit that is rented,leased or let shall be
equipped with a window sash locking device.
Pass 2015 IPMC 304.5-Foundation walls
OFoundation walls shall be maintained plumb and free from
open cracks and breaks and shall be kept in such condition
so as to prevent the entry of rodents and other pests.
GENERATED ON 9/22/26, 12:11 PM 5 OF 28
Fail 2015 IPMC 304.7-Roofs and drainage
The roof and flashing shall be sound,tight and not have Location:Exterior
defects that admit rain.Roof drainage shall be adequate to Comments:All the down spouts and draining or dripping from roof
prevent dampness or deterioration in the walls or interior directly to the foundation.
portion of the structure.Roof drains,gutters and downspouts
shall be maintained in good repair and free from obstructions.
Roof water shall not be discharged in a manner that creates a
public nuisance.
Pass 2015 IPMC 307.1-General-Handrails&Guards
Cj Every exterior and interior flight of stairs having more than
four risers shall have a handrail on one side of the stair and
every open portion of a stair,landing,balcony,porch,deck,
ramp or other walking surface that is more than 30 inches
(762 mm)above the floor or grade below shall have guards.
Handrails shall be not less than 30 inches(762 mm)in height
or more than 42 inches(1067 mm)in height measured
vertically above the nosing of the tread or above the finished
floor of the landing or walking surfaces.Guards shall be not
less than 30 inches(762 mm)in height above the floor of the
landing,balcony,porch,deck,or ramp or other walking
surface.
Pass 506.1-Where required.
C. Where access to or within a structure or an area is restricted
because of secured openings or where immediate access is
necessary for life-saving or fire-fighting purposes,the fire
code official is authorized to require a key box to be installed
in an approved location.The key box shall be of an approved
type listed in accordance with UL 1037,and shall contain
keys to gain necessary access as required by the fire code
official.
GENERATED ON 0/22/26, 12:11 PM 6 OF 28
2015 IPMC Interior Property
._.,:. C:od=, Description
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Portch
maintained in good,clean and sanitary condition.Peeling, Comments:Holes punched in walls.Missing plaster,missing
chipping,flaking or abraded paint shall be repaired,removed flooring.All need to be corrected.
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
i
tj-
y/1 , '� .'
. - '" '
I
w "" ? K ,i,yL -,
'. I ..�
V4' 1IP , I !( .b t
Fail 2015 IPMC 305.3-Interior surfaces
OInterior surfaces,including windows and doors,shall be Location:Living room
maintained in good,clean and sanitary condition.Peeling, Comments:Missing plaster and lath.This must be repaired
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
,
4,...: 1:1\1:: .......,........ ... :L....'•,1
I i ; .: V
' I \i
I\I.
' * L '
,r
i t +.
111A . ,r,
L .
.. ''
...
„....... . , : „
ti, ,
, ..
4 `'
r. e . .
GENERATED ON 9/22/2e, 12:11 PM / OF a:,
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Kitchen
maintained in good,clean and sanitary condition.Peeling, Comments:Missing areas of ceiling.Could have exposed wires
chipping,flaking or abraded paint shall be repaired,removed where light fixtures used to be.
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
+/ •
<w r,
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Kitchen
maintained in good,clean and sanitary condition.Peeling, Comments:Door and drawers are missing from cabinets and need to
chipping,flaking or abraded paint shall be repaired,removed be repaired.
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
,.
p i
. ..
,, ....,
, • .1 u
' A:4
, , - . f I:,
I, 1 . 1 ..,0::*,':: A i r:,41: . ,,,c-03;i,
•
- ,. A - r"
.„. ,
GENERATED ON 9/22/26, 12:11 PM 8 OF 28
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Stairs going to upper level
maintained in good,clean and sanitary condition.Peeling, Comments:Missing plaster
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
•
t /'
.a-. t
i. r5R'
a
c ,r4
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Upstairs bedroom
maintained in good,clean and sanitary condition.Peeling. Comments:Missing door knob on door.
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
0,7
..x
4 IY
,
GENERATED ON 9/22/28, 12:11 PM 9 OF 29
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Bathroom upstairs
maintained in good,clean and sanitary condition,Peeling, Comments:Cracks in walls need attention
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
‘•
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Kitchen
maintained in good,clean and sanitary condition.Peeling, Comments:Flooring being peeled back and breaking
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
\; w
Y; ,t`�
1 t
"ffr
firt,
, �k`; fig. 11
'
Fail 2015 IPMC 305.3-Interior surfaces
Ox Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition.Peeling,
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
Not set 2015 IPMC 305.4-Stairs and walking surfaces
Every stair,ramp,landing,balcony,porch,deck or other
walking surface shall be maintained in sound condition and
good repair.
GENERATED ON 9/22/28, 12:11 PM 10 OF 28
•
2015 IPMC Egress Components
Status Code Description
Fail 2015 IPMC 305.4-Stairs and walking surfaces
Ux Every stair,ramp,landing,balcony,porch,deck or other Location:Rear deck/steps
walking surface shall be maintained in sound condition and Comments:Steps are rotten and gone.Deck is rotten,broken,and
good repair, falling apart.Trash blocking exit
i z+
R-----, I-r: 110.., ' '
,I., ...4 ,
i______,i z
_ , .
z. , . 0 4
7 ,.,
. ..,
c.
Fail 2015 IPMC 305.5-Handrails and guards
OEvery handrail and guard shall be firmly fastened and capable Location:Steps going upstairs
of supporting normally imposed loads and shall be Comments:Missing hand rail.
maintained in good condition
Pass 2015 IPMC 307.1-General-Handrails&Guards
OEvery exterior and interior flight of stairs having more than
four risers shall have a handrail on one side of the stair and
every open portion of a stair,landing,balcony,porch,deck,
ramp or other walking surface that is more than 30 inches
(762 mm)above the floor or grade below shall have guards.
Handrails shall be not less than 30 inches(762 mm)in height
or more than 42 inches(1067 mm)in height measured
vertically above the nosing of the tread or above the finished
floor of the landing or walking surfaces.Guards shall be not
less than 30 inches(762 mm)in height above the floor of the
landing,balcony,porch,deck,or ramp or other walking
surface.
GENERATED ON 9/22/28, 12;11 PM 11 OF 28
Fail 2015 IPMC 702.4=Emergency escape openings
4
Required emergency escape openings shall be maintained in Location:Rear door
accordance with the code in effect at the time of construction, Comments:Egress blocked with trash,This needs to be removed to
and the following.Required emergency escape and rescue allow tenants to exit in case of an emergency.
openings shall be operational from the inside of the room
without the use of keys or tools,Bars,grilles,grates or
similar devices are permitted to be placed over emergency
escape and rescue openings provided the minimum net clear
opening size complies with the code that was in effect at the
time of construction and such devices shall be releasable or
removable from the inside without the use of a key,tool or
force greater than that which is required for normal operation
of the escape and rescue opening,
l r.
' ♦ .Mb a
\ 5 ` e ,,--
t '', j :i.:1 %:. ' `':' 'I'M l'ili • '
•
'4'.fib`. 7`� w._ -
0
Pass 2021 IBC 1031.2-Emergency Escape and Rescue
C) Where Required:In addition to the means of egress required
by this chapter,emergency escape and rescue openings shall
be provided in the following occupancies:1.R-2 occupancies
located in stories with only one exit or access to only one exit
as permitted by Tables 1006.3.4(1)and 1006.3.4(2)2.Group
R-3 and R-4 Occupancies.Exceptions:1.Basements with
Ceiling heights less than 80"2.Basements or sleeping rooms
with an exit or exit or exit access door that opens directly to
public way 3.Basements with no habital spaces and less than
200 Square feet 4.Storm Shelters 5.Within individual
dwelling and sleeping units in groups R-2 and R-3,where the
building is equipped with an automatic sprinkler system
installed in accordance with Section 903.3.1.1,903.3.1.2 or
903.3.1.3,sleeping rooms in basements shall not be required
to have emergency and rescue openings provide the
basement has one of the following:5.1 one means of egress
and one emergency escape and rescue opening.5.2 Two
means of egress.
N/A 705.2.4-Door operation.
Swinging fire doors shall close from the full-open position
and latch automatically.
GENERATED ON 9/22/28, 12:11 PM 12 OF 28
•
Not set 2015 IPMC 304.15•Doors
Exterior doors,door assemblies,operator systems If
provided,and hardware shall be maintained in good
condition.Locks at all entrances to dwelling units and
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3.
GENERATED ON 9/22/28, 12;11 PM 13 OF 28
2015 IPMC Rubbish&Garbage
satus ^.oily Description
Fail 2015 IPMC 308.1-Accumulation of rubbish or garbage
Exterior property and premises,and the interior of every Location:Exterior of Property
structure,shall be free from any accumulation of rubbish or Comments:Trash,scrap metal,tires,garbage,car parts,discarded
garbage. food,and broken furniture laying outside in grass.All of which need
to be removed.
,
i f Io , / "
ii I _
h ` =
0 r,-.'"---''' -1-7-
, [ Pr
` '
1t t�
crk yR'. . ems ` ✓ �,. .. � _ -'
t.r_ 1,t,YY 5J v� k t. `1 fl[Vy
1111 i t l �+ r
, ,-____.r,___ ..., ,
, ,,i---------------7 .ce
7 ,,---ki -------- i-. m•-: • ,, ' - .•..-... 4,1 '""•----.l._,______,__,::;440
_._,,t r , . , _ _ ,.
. ,,,,, - .,, , ,_
i ,,..„, _ . 4. . „.....„, ,._.
, , ......... :_,,... ..v., ,
_ . : i
., _. . , , . N
11
Pass 2015 IPMC 308.2-Disposal of rubbish
ci Every occupant of a structure shall dispose of all rubbish in a
clean and sanitary manner by placing such rubbish in
approved containers.
Pass 2015 IPMC 308,2.1-Rubbish storage facilities
�; The owner of every occupied premises shall supply approved
covered containers for rubbish,and the owner of the
premises shall be responsible for the removal of rubbish.
GENERATED ON 9/22/28, 12:11 PM 14 OF 28
Pass 2015 IPMC 308.2.2•Refrigerators
0 Refrigerators and similar equipment not In operation shall not
be discarded,abandoned or stored on premises without first
removing the doors.
Pass 2015 IPMC 308.3-Disposal of garbage
0 Every occupant of a structure shall dispose of garbage in a
clean and sanitary manner by placing such garbage in an
approved garbage disposal facility or approved garbage
containers.
Pass 2015 1PMC 308.3.1-Garbage facilities
OThe owner of every dwelling shall supply one of the following:
an approved mechanical food waste grinder in each dwelling
unit;an approved incinerator unit in the structure available to
the occupants in each dwelling unit;or an approved
leakproof,covered,outside garbage container.
Pass 2015 IPMC 308.3.2-Containers
l_J The operator of every establishment producing garbage shall
provide,and at all times cause to be utilized,approved
leakproof containers provided with close-fitting covers for the
storage of such materials until removed from the premises for
disposal.
GENERATED ON 0/22/20, 12:11 PM 15 OF 28
2015 IPMC Pest Elimination
Status Code Description
Fail 2015 IPMC 309.1-Infestation
Ox Structures shall be kept free from insect and rodent Location:entire residence
infestation.Structures in which insects or rodents are found Comments:I noticed many flies in the area.Directly out of the back
shall be promptly exterminated by approved processes that door was meat of some sort.These bugs would be able to come into
will not be injurious to human health.After pest elimination, the house,I also noticed some dead cockroaches.I did not see any
proper precautions shall be taken to prevent reinfestation, alive cockroaches upon this inspection.
• �; ►
,tea
6
4600:sx
•
k yg
Pass 2015 IPMC 309.2-Owner
Ci The owner of any structure shall be responsible for pest
elimination within the structure prior to renting or leasing the
structure.
Pass 2015 IPMC 309.3-Single occupant
C' The occupant of a one-family dwelling or of a single-tenant
nonresidential structure shall be responsible for pest
elimination on the premises.
N/A 2015 IPMC 309.4-Multiple occupancy
The owner of a structure containing two or more dwelling
units,a multiple occupancy,a rooming house or a
nonresidential structure shall be responsible for pest
elimination in the public or shared areas of the structure and
exterior property.If infestation is caused by failure of an
occupant to prevent such infestation in the area occupied,the
occupant and owner shall be responsible for pest elimination.
Pass 2015 IPMC 309.5-Occupant
The occupant of any structure shall be responsible for the
continued rodent and pest-free condition of the structure.
Exception:Where the infestations are caused by defects in
the structure,the owner shall be responsible for pest
elimination.
GENERATED ON 9/22/26, 12:11 PM 16 OF 28
2015 IPMC Ventilation
Status Code Description
Pass 2015 IPMC 403.1-Habitable spaces
O Every habitable space shall have not less than one openable
window.The total openable area of the window In every room
shall be equal to not less than 45 percent of the minimum
glazed area required In Section 402.1 Exception:Where
rooms and spaces without openings to the outdoors are
ventilated through an adjoining room,the unobstructed
opening to the adjoining room shall be not less than 8
percent of the floor area of the interior room or space,but not
less than 25 square feet(2.33 m2).The ventilation openings to
the outdoors shall be based on a total floor area being
ventilated.
Pass 2015 IPMC 403.2-Bathrooms and toilet rooms
OEvery bathroom and toilet room shall comply with the
ventilation requirements for habitable spaces as required by
Section 403.1,except that a window shall not be required in
such spaces equipped with a mechanical ventilation system.
Air exhausted by a mechanical ventilation system from a
bathroom or toilet room shall discharge to the outdoors and
shall not be recirculated.
2015 IPMC Water System
Status Code Description
Pass 2015 IPMC 504.1-General-Plumbing Facilities and Fixture
0 Requirements
Plumbing fixtures shall be properly installed and maintained
in working order,and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
Pass 2015 IPMC 505.1-General-Water System
0 Every sink,lavatory,bathtub or shower,drinking fountain,
water closet or other plumbing fixture shall be properly
connected to either a public water system or to an approved
private water system.Kitchen sinks,lavatories,laundry
facilities,bathtubs and showers shall be supplied with hot or
tempered and cold running water in accordance with the
International Plumbing code
NIA 2015 IPMC 505.4-Water heating facilities
Water heating facilities shall be properly installed,maintained
and capable of providing an adequate amount of water to be
drawn at every required sink,lavatory,bathtub,shower and
laundry facility at a minimum temperature of 110°F(43°C).A
gas-burning water heater shall not be located in any
bathroom,toilet room,bedroom or other occupied room
normally kept closed,unless adequate combustion air is
provided.An approved combination temperature and
pressure-relief valve and relief valve discharge pipe shall be
properly installed and maintained on water heaters
GENERATED ON 9/22/28, 12:11 PM 17 OF 28
2015 IPMC Mechanical
Code Description
Fail 2015 IPMC 603.1-Mechanical appliances
Mechanical appliances,fireplaces,solid fuel-burning Location:Kitchen
appliances,cooking appliances and water heating appliances Comments:Front of the stove Is broke.Needs to be replaced.
shall be properly installed and maintained in a safe working
condition,and shall be capable of performing the Intended
function.
Pass 2015 IPMC 603.2-Removal of combustion products
0 Fuel-burning equipment and appliances shall be connected to
an approved chimney or vent.Exception:Fuel-burning
equipment and appliances that are labeled for unvented
operation.
Pass 315.3.3-Equipment rooms.
Combustible material shall not be stored in boiler rooms,
mechanical rooms,electrical equipment rooms or in fire
command centers as specified in Section 508.1.5.
GENERATED ON 9/22/28, 12:11 PM 18 OF 28
2015 IPMC Electrical
Status Code Description
Fail 2015 IPMC 605.2-Receptacles
Every habitable space In a dwelling shall contain not less Location:Entire dwelling
than two separate and remote receptacle outlets.Every Comments:All light switches,receptacles,and junction boxes must
laundry area shall contain not less than one grounding-type be protected with face places
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
•
34
**bs
•
Fail 2015 IPMC 605.2-Receptacles
t Z Every habitable space in a dwelling shall contain not less Location:Downstairs bathroom
than two separate and remote receptacle outlets.Every Comments:Receptacle is not up to code
laundry area shall contain not less than one grounding-type
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
•
• //J
icy'. /.
v h
GENERATED ON 9/22/2G, 12:11 PM 19 OF 28
Fail 2015 IPMC 605.3-Luminaires
O Every public hall,interior stairway,toilet room,kitchen, Location:Front Steps on exterior of porch
bathroom,laundry room,boiler room and furnace room shall Comments:Missing globe on light fixture.All light fixtures must have
contain not less than one electric luminaire.Pool and spa a globe protecting the bulbs.
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 605.3-Luminaires
O Every public hall,interior stairway,toilet room,kitchen, Location:Dining room
bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture missing globe.All light fixtures must have
contain not less than one electric luminaire.Pool and spa covers or globes
luminaires over 15 V shall have ground fault circuit
interrupter protection.
GENERATED ON 0/22/28, 12:11 PM 20 OF 28
•
Fail 2015 IPMC 605.3-Luminaires
O Every public hall,interior stairway,toilet room,kitchen, Location:Kitchen
bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture is held up with a hook and is pigtailed into
contain not less than one electric luminaire.Pool and spa an extension cord and then plugged Into a receptacle.This must be
luminaires over 15 V shall have ground fault circuit removed.
interrupter protection.
r
-- ._ ;.
/ '/
.. - { ,
_ evir: „ .i
,, �r
Fail 2015 IPMC 605.3-Luminaires
OEvery public hall,interior stairway,toilet room,kitchen, Location:hallway outside of bedrooms
bathroom,laundry room,boiler room and furnace room shall Comments:Missing globe on light fixture.Must be replaced.
contain not less than one electric luminaire.Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
�
S
,
GENERATED ON 9/22/28, 12:11 PM 21 OF 28
Fail 2015 IPMC 605.3-Luminaires
Every public hall,Interior stairway,toilet room,kitchen, Location:Upstairs bathroom
bathroom,laundry room,boiler room and furnace room shall Comments:Vanity light missing a bulb.This must be replaced to
contain not less than one electric luminaire.Pool and spa prevent someone getting shocked,
luminaires over 15 V shall have ground fault circuit
interrupter protection,
ter .
Fail 2015 IPMC 605.3-Luminaires
Every public hall,interior stairway,toilet room,kitchen, Location:Bedroom#1 upstairs(clockwise)
bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture needs to be wired correctly.I can not have
contain not less than one electric luminaire.Pool and spa any exposed wires
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 605.3-Luminaires
Every public hall,interior stairway,toilet room,kitchen, Location:Rear exit
bathroom,laundry room,boiler room and furnace room shall Comments:Missing light cover
contain not less than one electric luminaire.Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
GENERATED ON 9/22/26, 12:11 PM 22 OF 28
Fail 2015 IPMC 605.4-Wiring
Flexible cords shall not be used for permanent wiring,or for Location:Front Steps on exterior of porch
running through doors,windows,or cabinets,or concealed Comments:Cords plugged in used a permanent wiring.This needs to
within walls,floors,or ceilings be removed
Pass 603.2-Abatement of unsafe conditions and electrical
Ohazards.
Identified electrical hazards shall be abated.Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Pass 603.5-Relocatable power taps and current taps.Multiplug
Oadapters.
Multiplug adapters,such as cube adapters,unfused plug
strips or any other device not complying with NFPA 70 shall
be prohibited.The construction and use of current taps and
relocatable taps shall be in accordance with NFPA 70 and this
code.
GENERATED ON 9/22/28, 12:11 PM 23 OF 28
2015 IPMC Fire Protection
Status Code Description
N/A 2015 IPMC 703.1-Fire-resistance-rated assemblies
The required fire-resistance rating of fire-resistance-rated
walls,fire stops,shaft enclosures,partitions and floors shall
be maintained.
N/A 2015 IPMC 703.2-Opening protectives
Required opening protectives shall be maintained in an
operative condition.Fire and smokestop doors shall be
maintained in operable condition.Fire doors and smoke
barrier doors shall not be blocked or obstructed or otherwise
made inoperable.
N/A 2015 IPMC 704.1-FIRE PROTECTION SYSTEMS-General
Systems,devices and equipment to detect a fire,actuate an
alarm,or suppress or control a fire or any combination
thereof shall be maintained in an operable condition at all
times in accordance with the International Fire Code.
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and 1.1
Single or multiple-station smoke alarms shall be installed and Location:Hallway outside upstairs bedrooms
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Missing smoke detector.All bedrooms/sleeping rooms
occupant load at all of the following locations:1.On the must have a smoke detector outside of them.This could be a
ceiling or wall outside of each separate sleeping area in the combination smoke detector/carbon monoxide detector.It must have
immediate vicinity of bedrooms.2.In each room used for UL217 listed on it and must be a 10 year sealed unit.
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and 1-1
Single or multiple-station smoke alarms shall be installed and Location:Hallway outside downstairs bedrooms
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Missing smoke detector.All bedrooms/sleeping rooms
occupant load at all of the following locations:1.On the must have a smoke detector outside of them.This could be a
ceiling or wall outside of each separate sleeping area in the combination smoke detector/carbon monoxide detector.It must have
immediate vicinity of bedrooms.2.In each room used for UL217 listed on it and must be a 10 year sealed unit.
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location:Basement
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Missing smoke detector.There must be a smoke detector
occupant load at all of the following locations:1.On the outside each bedroom or cluster of bedrooms
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
GENERATED ON 9/22/25, 12:11 PM 24 OR 28
Fall 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I.1
Single or multiple-station smoke alarms shall be installed and Location:Bedroom#1 Upstairs(clockwise)
maintained In Groups R-2,R-3,R-4 and I.1 regardless of Comments:Missing smoke detector.There must be a smoke detector
occupant load at all of the following locations:1.On the In each bedroom/sleeping room.
ceiling or wall outside of each separate sleeping area in the
Immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I.1
Single or multiple-station smoke alarms shall be installed and Location:Bedroom#2 upstairs(clockwise)
maintained in Groups R-2,R-3,R-4 and I-i regardless of Comments:Missing smoke detector.There must be a smoke detector
occupant load at all of the following locations:1.On the in each bedroom/sleeping room.
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location:Main level
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Missing smoke detector.There must be a smoke detector
occupant load at all of the following locations:1.On the in each bedroom/sleeping room.
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2021 IRC R 314.1.1-Smoke Alarms:Listings
Smoke alarms shall be listed in accordance with UL 217. Location:Entire dwelling
Combination smoke and carbon monoxide alarms shall be Comments:All detectors must be UL217 listed.This should be
listed in accordance with 217 and UL 2034
printed on the unit
Fail 2021 IRC R315.3-Carbon Monoxide Detection:Location
Carbon monoxide alarms in dwelling units shall be installed Location:Hallway outside upstairs bedrooms
outside of each separate sleeping area in the immediate Comments:Missing carbon monoxide detector.All
vicinity of the bedrooms.Where a fuel-burning appliance is bedrooms/sleeping rooms must have a carbon monoxide detector
located within bedroom or its attached bathroom,a carbon outside of them.This could be a combination smoke detectorlcarbon
monoxide alarm shall be installed within the bedroom, monoxide detector.It must have UL217 listed on it and must be a 10
year sealed unit.
Fail 2021 IRC R315.3-Carbon Monoxide Detection:Location
Carbon monoxide alarms in dwelling units shall be installed Location:Main level outside bedrooms
outside of each separate sleeping area in the immediate Comments:Missing carbon monoxide detector.All
vicinity of the bedrooms.Where a fuel-burning appliance is bedrooms/sleeping rooms must have a carbon monoxide detector
located within bedroom or its attached bathroom,a carbon outside of them.This could be a combination smoke detector/carbon
monoxide alarm shall be installed within the bedroom. monoxide detector.It must have UL217 listed on it and must be a 10
year sealed unit.
GENERATED ON 9/22/26, 12:11 PM 25 OF 28
N/A 906.1•Where required.
Portable fire extinguishers shall be Installed In all of the
following locations:1.In new and existing Group A,B,E,F,H,
I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group
R-2 occupancies,portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
dwelling unit is provided with a portable fire extinguisher
having a minimum rating of 1-A:10-B:C.2.In Group E
occupancies,portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C,3.In storage areas of Group
S occupancies where forklift,powered industrial truck or
powered cart operators are the primary occupants,fixed
extinguishers,as specified in NFPA 10,shall not be required
where in accordance with all of the following:3.1,Use of
vehicle-mounted extinguishers shall be approved by the fire
code official.3.2.Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a
mounting bracket approved by the extinguisher manufacturer
or the fire code official for vehicular use.3.3.Not less than
two spare extinguishers of equal or greater rating shall be
available on-site to replace a discharged extinguisher.3.4.
Vehicle operators shall be trained in the proper operation,use
and inspection of extinguishers.3.5.Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30
feet(9144 mm)distance of travel from commercial cooking
equipment and from domestic cooking equipment in Group I-
1;1-2,Condition 1;and R-2 college dormitory occupancies.
3.In areas where flammable or combustible liquids are stored,
used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance
with Section 3316.1.5.Where required by the sections
indicated in Table 906.1.6.Special-hazard areas,including but
not limited to laboratories,computer rooms and generator
rooms,where required by the fire code official.Exception:
Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where
a portable fire extinguisher suitable to the hazard of the
location is provided on the vehicle of visiting personnel.
GENERATED ON 9/22/26, 12:11 PM 26 OF 28
NIA Iowa Code 861-201.15(7)•Smoke Alarm Power Supplies
Power supplies shall be sufficient to operate the smoke
detector alarm for at least four continuous minutes.
Additionally:a.In new buildings and additions constructed
after July 1,1991,required smoke alarms will receive their
primary power from the building wiring when such wiring is
served from a commercial source.Wiring will be permanent
and without a disconnecting switch other than that required
for overcurrent protection.Smoke alarms may be solely
battery-powered when installed in existing buildings;in
buildings without commercial power;or in buildings
presently undergoing alterations,repairs,or additions subject
to 481—Chapter 404.b.New and replacement smoke alarms
installed after May 1,1993,that receive their primary power
from the building wiring will be equipped with a battery
backup.c.New and replacement smoke alarms installed after
July 1,2016,that receive their primary power from the
building wiring where more than one smoke alarm is required
to be installed will be interconnected in such a manner that
the activation of one alarm will activate all of the alarms.d.
After June 30,2021,a battery-powered smoke alarm listed in
accordance with UL 217 edition 8 that is newly installed or
replaces an existing battery-powered smoke alarm must be
powered by a nonremovable,nonreplaceable battery that
powers the alarm for at least ten years.The battery
requirements of this subruie do not apply to a fire alarm,
smoke detector,smoke alarm,or ancillary component that is
electronically connected as a part of a centrally monitored or
supervised alarm system or that uses a low-power,radio
frequency wireless communication signal.
GENERATED ON 9/22/2G, 12:11 PM 27 OF 28
•
E'® Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
N/A $100.00
Invoice Number Check Number Transaction Number
N/A N/A N►A
GENERATED ON 9/22/26, 12:11 PM 28 OF 28