Loading...
HomeMy WebLinkAboutPunchlist 2-6-20UP UP EX BILGE PUMP EX SEWAGE PUMP EX 6" SS EX 3" SS UP EX 4" SS UP EX 3" SS UP EX 3" V UP GI-1 EX S 4" FD-1 EX L 4" FD-1 4" FD-1 4" FS-1 4" FD-1 4" FD-1 4" FD-1 4" FD-1 4" FD-1 4" FS-14" FD-1 4" FD-1 4" FS-1 4" FS-1 TD-1 EX 2" V UP EX 6" SS EX 4" CO CO CO CO CO CO CO 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 TD-1 6 5 EX L EX S EX 4" SS 4" SS 4" SS 4" SS 4" SS 4" SS 4" SS 4" SS EX 4" SS 4" SS 3" SS 2" V 4" SS 3" SS 3" SS 3" SS 4" SS 4" SS4" SS 4" SS EX 1-1/4" V UP 2" V UP 3" V UP 2" V UP 2" V 2" V UP 2" V REMOTE CLEANOUT 4" SS 10 10 10 10 10 11 11 11 CO CO CO EX 2" V UP 2" V 2" V 3" V SAMPLE PORT EX 1-1/2" V UP EX 4" SS EX 4" SS 3" V KITCHEN PREPARATION 013 32 KITCHEN WASH AREA 012 31 TRASH 011 30 STORAGE 006 23 MEN 007 24 WOMEN 008 25 OFFICE 009 26 STORAGE 010 27 WALK - IN REGRIG./ FREEZER 21 JANITOR 020 37 ELEVATOR 20 ELEV. EQUIP. ROOM 019 36 LOADING DOCK 29 EX 3" SS DN EX 4" SS DN EX 3" SS DN EX 3" V DN2" V DN EX 3" V DN/UP EX 2" V EX 1-1/2" V EX 2" V DN EX 1-1/2" V DN EX 2" V DN EX 3" V UP EX 3/4" HW EX 1-1/4" CW/HW EX 1" HW EX 2" CW/HW EX 3" SS EX 3" SS EX 2" V EX 4" SS EX 4" SS EX 2-1/2" V KITCHEN PREPARATION 013 32 WALK - IN REGRIG./ FREEZER 21 STORAGE 010 27OFFICE 009 26WOMEN 008 25 MEN 007 24 STORAGE 006 23 KITCHEN WASH AREA 012 31 TRASH 011 30 LOADING DOCK 29 1-1/4" HW DN 3/4" CW DN 3/4" HW/CW DN 3/4" CW/HW 3/4" CW/HW DN 3/4" HW 3/4" CW 1" CW 1" CW/HW 1-1/2" CW/HW 3/4" HW 3/4" CW/HW 1/2" HW 1/2" HW 4" FD-1 4" FD-1 4" FD-1 4" FS-1 4" FD-1 4" FD-1 4" FD-1 4" FD-1 4" FD-1 4" FS-1 4" FD-1 4" FD-1 4" FS-1 4" FS-1 TD-1 TD-1 2" V DN 2" V 3 4 6 GI-1 8 79 9 9 12 12 3" V DN EX 4" V UP EX 4" DN 3" V 3" V EX 4" V EX L EX L 3/4" CW/HW DN 3/4" CW DN EX 1-1/2" V DN 1-1/2" V DN 1-1/2" V DN 1-1/2" V DN 1-1/2" V DN EX 1-1/4" V DN EX 2" V DN 1-1/2" V DN 1-1/2" V DN 1-1/2" V DN 1-1/2" V DN EX DISHWASHER EX HOOD EX 2" V EX 2" V DN EX 2-1/2" V EX 2" V EX 3" V 1-1/2" V 1-1/2" V DN 3" V DN EX S EX S GENERAL NOTES: A. INSTALLATION PLANS ARE SCHEMATIC IN NATURE. CONTRACTOR TO VERIFY PLACEMENT OF NEW EQUIPMENT/FIXTURES PRIOR TO INSTALLATION. B. MAINTAIN SERVICE CLEARANCE AROUND ALL MECHANICAL EQUIPMENT AND ABOVE ELECTRICAL EQUIPMENT. DO NOT ROUTE PIPING IN CLEARANCE SPACE. C. COORDINATE PIPING LAYOUT AND ELEVATIONS WITH FOOTINGS, FLOW LINES, LOCAL PLUMBING CODE AND THE SPECIFICATIONS. D. VERIFY ALL SITE CONDITIONS PRIOR TO START OF WORK. E. COORDINATE ALL PLUMBING AND PIPING ROUTING WITH BUILDING STRUCTURE AND OTHER TRADES PRIOR TO INSTALLATION TO ALLOW FOR PROPER CLEARANCES AND FLOW REQUIREMENTS. F. COORDINATE ALL VENTS THROUGH ROOF WITH STRUCTURAL DRAWINGS AND MAINTAIN 10FT REQUIRED DISTANCE FROM MECHANICAL EQUIPMENT INTAKES. OFFSET PIPING AS NECESSARY. G. COORDINATE ALL EXPOSED PIPE ROUTING WITH DESIGN TEAM PRIOR TO ROUGH-IN. SPECIFIC RACKING REQUIREMENTS MAY BE REQUIRED. H. COORDINATE ALL FLOOR DRAIN LOCATIONS WITH MECHANICAL EQUIPMENT AND RESPECTIVE TRADES PRIOR TO ROUGH-IN. I. COORDINATE STORM AND SANITARY SEWER CONNECTIONS WITH STRUCTURAL DRAWINGS TO MAINTAIN REQUIRED SLOPING AND PROPER ELEVATIONS. J. SEE PLUMBING FIXTURE CONNECTION SCHEDULE FOR FIXTURE CONNECTION SIZES. K. FIELD VERIFY ALL NEW AND EXISTING PIPE ROUTING WITH EXISTING CONDITIONS PRIOR TO ROUGH-IN. MAKE NECESSARY OFFSETS AS REQUIRED. L. COORDINATE ALL WALL CLEANOUT LOCATIONS WITH DESIGN TEAM PRIOR TO ROUGH-IN. COORDINATE ALL FLOOR CLEANOUT LOCATIONS BEING INSTALLED IN TILE, TERRAZZO OR OTHER SPECIALTY FLOOR AREAS WITH DESIGN TEAM PRIOR TO ROUGH-IN. M. EXISTING SANITARY SEWER MAIN DEPTH IS APPROXIMATELY 6FT DEEP. EXISTING SANITARY SEWER BRANCH LINES ARE APPROXIMATELY 3FT DEEP. N. EXISTING UNDERFLOOR CONDITIONS WERE TAKEN FROM EXISTING PLANS AND MAY NOT REFLECT EXACT SITE CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ADDITIONAL CONCRETE REMOVAL AS REQUIRED TO REMOVE SANITARY SEWER PIPING. REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION REGARDING FLOOR CUTTING AND PATCHING. O. COORDINATE ALL DRAIN LOCATIONS WITH EXISTING AND NEW OWNER KITCHEN EQUIPMENT PRIOR TO ROUGH-IN. REFERENCED NOTES: 1. INSTALL NEW FLOOR DRAIN IN APPROXIMATE LOCATION OF REMOVED FLOOR DRAIN. 2. INSTALL NEW TRENCH DRAIN. COORDINATE WITH EXISTING EQUIPMENT LAYOUT AND OWNER FOR EXACT LOCATION. TRENCH DRAIN SERVES OR MAY SERVE TIPPING KETTLE. VERIFY TIPPING DRAINAGE FLOW DISTANCES PRIOR TO ROUGH-IN. 3. ROUTE SANITARY PIPING FROM EXISTING DISPOSAL INTO SANITARY SEWER SYSTEM. 4. ROUTE EXISTING SINK DRAIN TO NEW FLOOR DRAIN UNDER EXISTING SINK. 5. COORDINATE SANITARY PIPING INSTALLATION WITH EXISTING PIPING ELEVATIONS. 6. INSTALL NEW GREASE INTERCEPTOR. COORDINATE EXACT LOCATION WITH DESIGN TEAM. 7. INSTALL NEW DOMESTIC WATER LINES TO SERVE EXISTING EQUIPMENT PREVIOUSLY SERVED FROM UNDERFLOOR. 8. CONNECT NEW DOMESTIC WATER TO EXISTING DISHWASHER. 9. COORDINATE INSTALLATION OF DOMESTIC WATER PIPING DROPS WITH ARCHITECTURAL PLAN. 10. COORDINATE PIPING IN THIS AREA WITH EXISTING UNDERFLOOR CONDUIT, REBAR, AND WIRE MESH. 11. INSTALL AT LEAST 10' OF STAINLESS STEEL PIPING BEFORE TRANSITIONING TO PVC. 12. INSTALL DOMESTIC WATER PIPING IN EXISTING WALL. SEE ARCHITECTURAL DRAWING FOR EXACT LOCATION OF WALLS. # ADS CORRUGATED PIPE. KITCHEN SAN. SEWER 4" C.O. REINFORCE CONCRETE PAVING ABOVE GREASE INTERCEPTOR. 6" 12 " 4" 12 " 4" 4" VENT 24" C.O. STATIC WATER LINE HDPE, 1250 GAL GREASE INTERCEPTOR. (BASED ON MIFAB)12 " 4" 24" C.O.C.O. DIRECT CONNECT LID. H-20 LOAD RATED LID. 4" 6" PLANNING ARCHITECTURE INTERIORS Copyright C 2016 OWNER SIGN-OFF: SHEET NAME: PROJECT NO: DATE: SHEET SET: REVISIONS: DATE SHEET: NAME 501 Sycamore Street Suite 101 Waterloo, IA 50703 319.233.8419 319.233.9772 Fax www.invisionarch.com CONSULTANT: 19-085 FIVE SULLIVAN BROTHERS KITCHEN SANITARY SEWER REPLACEMENT P101 10.11.2019 PLUMBING NEW WORK PLAN 16021 5 S U L L I V A N B R O T H E R C O N V E N T I O N CE N T E R K I T C H E N R E M O D E L 20 0 W 4 T H S T , W A T E R L O O , I A 5 0 7 0 1 Ow n e r BID DOCUMENTS 1/8" = 1'-0"1 UNDERFLOOR PLUMBING PLAN 1/8" = 1'-0"2 ABOVE FLOOR PLUMBING PLAN GREASE INTERCEPTOR SCHEDULE UNIT TAG MANUFACTURER MODEL FLOW RATE (GPM) GREASE CAPACITY (LBS) LIQUID HOLDING CAPACITY (GAL) GI-1 MIFAB SUPER-MAX 1250 250 4,983 1250 PLUMBING FIXTURE SCHEDULE UNIT TYPE MANUFACTURER MODEL MATERIAL COLOR ADA FIXTURE DESCRIPTION MISCELLANEOUS FD-1 FLOOR DRAIN WATTS FD-1100-A - - - EPOXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, REVERSIBLE CLAMPING COLLAR WITH PRIMARY AND SECONDARY WEEPHOLES, STAINLESS STEEL STRAINER, NO HUB OUTLET. PROVIDE WITH MEMBRANE CLAMP FS-1 FLOOR SINK WATTS FS-790 - - - 12" SQUARE FLOOR SINK, 8" DEEP, TYPE 304 STAINLESS STEEL CONSTRUCTION. LOOSE SET CAST STAINLESS STELL GRATE, DOME BOTTOM STRAINER, NO HUB OUTLET. PROVIDE WITH MEMBRANE CLAMP TD-1 TRENCH DRAIN EAGLE ASFT-2436-SG-ADA STAINLESS STEEL - YES 36"x24" ANTI-SPLASH FLOOR TROUGH WITH TYPE 304 STAINLESS STEEL GRATE. 4" DIAMETER DRAIN No Scale3GREASE INTERCEPTOR SECTION VIEW DETAIL Description Date No.